Reproduction of inert gas and oxygenation data: a comparison of the MIGET and a simple model of pulmonary gas exchange
Open Access
- 6 August 2010
- journal article
- research article
- Published by Springer Nature in Intensive Care Medicine
- Vol. 36 (12) , 2117-2124
Abstract
The multiple inert gas elimination technique (MIGET) is the reference method for evaluating pulmonary gas exchange. MIGET includes a complex experimental method and mathematical model, and has not been used routinely in clinical practice. A simpler mathematical model has been proposed, and was shown previously to fit inert gas data from oleic acid damage. This paper explores the capability of this simple model to describe more complex damage, and to calculate oxygenation data upon changing the inspired oxygen fraction (FIO2), comparing these results with those obtained using MIGET. The comparison of oxygenation was done at different ventilator settings and at varying values of FIO2 in order to mimic the clinical conditions that occur in the intensive care unit. The simple model describes inert gas data from heterogeneous lung damage within measurement noise. Model simulations performed using the MIGET and the simple model are comparable, the MIGET model simulating partial pressure of oxygen (PaO2) values on average 0.22 ± 0.59 kPa (±SD) higher than the simple model. Model simulations are also accurate with a difference between model simulated and measured values of PaO2 of 0.33 ± 1.48 kPa (±SD) for the MIGET model and 0.12 ± 1.33 kPa (±SD) for the simple model. This comparability and accuracy was similar over different ventilator settings. The simple model provides a description of lung damage and arterial oxygenation which is comparable to the MIGET, calculating PaO2 with acceptable accuracy and precision over the clinically relevant range of PaO2, and for different values of FIO2, positive end-expiratory pressure (PEEP), and inspiratory-to-expiratory ratio (I:E).Keywords
This publication has 18 references indexed in Scilit:
- A comparison of methods to identify open-lung PEEPIntensive Care Medicine, 2009
- Variation in the PaO2/FiO2 ratio with FiO2: mathematical and experimental description, and clinical relevanceCritical Care, 2007
- Assessment of gas exchange in lung disease: balancing accuracy against feasibilityCritical Care, 2007
- Reproduction of MIGET retention and excretion data using a simple mathematical model of gas exchange in lung damage caused by oleic acid infusionJournal of Applied Physiology, 2006
- Modelling of hypoxaemia after gynaecological laparotomyActa Anaesthesiologica Scandinavica, 2001
- Hypoxemia after coronary bypass surgery modeled by resistance to oxygen diffusionCritical Care Medicine, 1999
- Quantifying pulmonary oxygen transfer deficits in critically ill patientsActa Anaesthesiologica Scandinavica, 1995
- Contribution of multiple inert gas elimination technique to pulmonary medicine. 5. Ventilation-perfusion relationships in acute respiratory failure.Thorax, 1994
- Ventilation-Perfusion Inequality in Patients Undergoing Cardiac SurgeryAnesthesiology, 1994
- Correlation of gas exchange impairment to development of atelectasis during anaesthesia and muscle paralysisActa Anaesthesiologica Scandinavica, 1986