Non-contact cardiopulmonary signal monitoring based on magnetic eddy current induction
Open Access
- 1 July 2023
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (7)
Abstract
The magnetic eddy current induction method has become an excellent solution for building home cardiopulmonary monitoring systems because of its non-contact and unobtrusive characteristics, but it has problems such as low precision and complex extraction of cardiopulmonary signals. Therefore, this paper designs a magnetic eddy current sensing system based on a Field Programmable Gate Array that can realize simultaneous real-time monitoring of cardiopulmonary signals. This system adopts a magnetic eddy current sensor design scheme that can improve the amount of cardiopulmonary information in the sensing signal. In addition, it uses a signal acquisition scheme that combines an inductance-to-digital converter (LDC) and oversampling technology to improve the resolution and signal-to-noise ratio of the sensing signal. Moreover, an optimized adaptive discrete wavelet transform algorithm is proposed in this system, which can realize the effective separation and extraction of cardiopulmonary signals in different respiration states. Comparing this system with the medical monitor, the cardiopulmonary signals obtained by the two have good consistency in the time-frequency domain. Under low motion, respiration rate and heart rate detected by this system are within the confidence interval of the 95% limit of agreement; the relative errors are less than 2.63% and 1.37%, respectively; and the accuracy rates are greater than 99.30% and 99.60%, respectively. In addition, an experiment with an asthmatic patient showed that the system still has good detection performance under pathological conditions and can monitor abnormal conditions such as coughing.Keywords
This publication has 30 references indexed in Scilit:
- Photoplethysmography Revisited: From Contact to Noncontact, From Point to ImagingIEEE Transactions on Biomedical Engineering, 2015
- A Bendable and Wearable Cardiorespiratory Monitoring Device Fusing Two Noncontact Sensor PrinciplesIEEE Journal of Biomedical and Health Informatics, 2015
- An adaptive Kalman filter approach for cardiorespiratory signal extraction and fusion of non-contacting sensorsBMC Medical Informatics and Decision Making, 2014
- Robust Pulse Rate From Chrominance-Based rPPGIEEE Transactions on Biomedical Engineering, 2013
- Noncontact Monitoring of Cardiorespiratory Activity by Electromagnetic CouplingIEEE Transactions on Biomedical Engineering, 2013
- Expert consensus document on the measurement of aortic stiffness in daily practice using carotid-femoral pulse wave velocityJournal Of Hypertension, 2012
- The smart car seat: personalized monitoring of vital signs in automotive applicationsPersonal and Ubiquitous Computing, 2011
- Wavelet packet transform for R-R interval variabilityMedical Engineering & Physics, 2004
- The displacement cardiograph. A noninvasive technique for recording myocardial wall motion.Circulation, 1976
- Measuring characteristics of the displacement cardiographMedical & Biological Engineering & Computing, 1973