LKLi Kong

Li Kong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Li Kong has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Non-contact cardiopulmonary signal monitoring based on magnetic eddy current induction

    by Li Kong, Gang Li, Yunyi Wang, Leiyang Cheng, Ling Lin

    The magnetic eddy current induction method has become an excellent solution for building home cardiopulmonary monitoring systems because of its non-contact and unobtrusive characteristics, but it has problems such as low precision and complex extraction of cardiopulmonary signals. Therefore, this paper designs a magnetic eddy current sensing system based on a Field Programmable Gate Array that can realize simultaneous real-time monitoring of cardiopulmonary signals. This system adopts a magnetic eddy current sensor design scheme that can improve the amount of cardiopulmonary information in the sensing signal. In addition, it uses a signal acquisition scheme that combines an inductance-to-digital converter (LDC) and oversampling technology to improve the resolution and signal-to-noise ratio of the sensing signal. Moreover, an optimized adaptive discrete wavelet transform algorithm is proposed in this system, which can realize the effective separation and extraction of cardiopulmonary signals in different respiration states. Comparing this system with the medical monitor, the cardiopulmonary signals obtained by the two have good consistency in the time-frequency domain. Under low motion, respiration rate and heart rate detected by this system are within the confidence interval of the 95% limit of agreement; the relative errors are less than 2.63% and 1.37%, respectively; and the accuracy rates are greater than 99.30% and 99.60%, respectively. In addition, an experiment with an asthmatic patient showed that the system still has good detection performance under pathological conditions and can monitor abnormal conditions such as coughing.


  • Open Access

    Wave Function and Multiscale Modeling of MMC-HVdc System for Wide-Frequency Transient Simulation

    by Hua Ye, Feng Gao, Wei Pei, Li Kong

    The detailed modeling of power electronic (PE) devices poses challenging problems to an efficient transient simulation of large-scale PE-dominated power systems. As PE paradigm, a multiscale modeling methodology of the modular multilevel converter (MMC) for simulating diverse transients from low-frequency oscillations up to high-frequency switching events in an MMC high-voltage direct current (HVdc) system is developed, implemented, and validated. The novelty lies in the creation of a wave propagation function (WPF) that describes the MMC submodule (SM) transient behavior, and then, the SM Fourier series-based shifted-frequency phasor (SFP) is developed to accelerate the computation speed of the system-level dynamics. These efforts serve as the basis for multiscale modeling of the MMC where a multiple-frequency shifting is achieved. By implementing a seamless model interface with the control systems, the multiscale modeling is applicable to an MMC-HVdc transmission system. The multiscale model is validated through case studies that cover dc fault, MMC internal fault, power oscillations, and wind power fluctuations. The computational accuracy and efficiency of the model are verified through a comparison of the results with those from the full electromagnetic transient (EMT) model.


  • Analysis and damping control of DC voltage oscillation in AC/DC hybrid distribution system

    by Luyang Li, Wei Pei, Wei Deng, Li Kong

    The complex impedance characteristic of DC network in AC/DC hybrid distribution system is easily to induce high-frequency oscillation. This paper reveals the influence of the DC line on the stability and upper limit of transmission power of the system by researching the relationship between the DC distribution line and the dominant eigenvalues of the system. A distributed active damping strategy is proposed, and the sensitivity of the active damping controller to the oscillation under different access positions is analyzed. Finally, time domain simulation verifies the correctness of the theory and the effectiveness of the proposed control strategy.


  • A comparative study of FOC for long stator linear synchronous motor control

    by Qiongxuan Ge, Yaohua Li, Li Kong

    This paper presents the principle of long stator linear synchronous motor (LSLSM) and introduces the mathematic modeling of LSLSM. A comparative study of three kinds of field oriented control (FOC) methods including the stator field oriented control (SFOC), airgap field oriented control (AFOC) and rotor field oriented control (RFOC) is given in detail. Comparison results show that for the demands of high performance operation of maglev vehicle, the RFOC control method is most suited for LSLSM control due to the decoupling of armature field and excitation field.