From Anatomical to Clinical DRLs: Establishing Indication-Based CT Dose Benchmarks in Saudi Arabia
Preprint
- 1 May 2026
- preprint
- Published by MDPI AG in Preprints.org
Abstract
Background: Although Diagnostic Reference Levels (DRLs) based on anatomical regions are widely used in Computed Tomography (CT) imaging, a clinical-indication-based approach provides a more accurate representation of daily practice and protocol variation. This study aimed to establish typical radiation doses for common CT clinical indications among adult patients at King Abdulaziz University Hospital (KAUH) in Saudi Arabia. Methods: This retrospective cross-sectional study included 298 adult patients who underwent CT examinations between 2020 and 2025 using two dual-source scanners operating in single- and dual-source modes. Demographic data, acquisition parameters, and radiation dose metrics, including volume CT dose index (CTDIvol) and the dose–length product (DLP) were extracted from scanner consoles. Six clinical indications were analyzed: brain trauma, sinusitis, chest metastases (chest Mets), interstitial lung disease (ILD), abdominopelvic metastases (AbdPel Mets), and hernia. Results: Typical median CTDIvol values in mGy were 36.4 for brain trauma, 3.4 for sinusitis, 4.9 for chest Mets, 5.6 for ILD, 7.2 for AbdPel Mets and hernia. Corresponding DLP values in mGy·cm were 654, 50, 173, 188, 344, and 369, respectively. Brain trauma demonstrated the highest radiation exposure, whereas sinusitis CT showed the lowest. Most values were comparable to or lower than international DRLs. Conclusions: This study provides the first comprehensive clinical-indication-based DRL data in Saudi Arabia beyond anatomical benchmarks, supporting ongoing dose optimization and future national DRL development.Keywords
All Related Versions
- Version 1, 2026-05-01, Preprints
- Published version: Diagnostics, 16 (12), 1897.
This publication has 23 references indexed in Scilit:
- A summary of updated UNSCEAR evaluations on medical and occupational exposures to ionising radiation and call for participation in UNSCEAR Global Surveys on radiation exposureRadiation Protection Dosimetry, 2024
- Establishment of a local diagnostic reference level for computed tomography chest and abdomen in two different cities in Saudi ArabiaApplied Radiation and Isotopes, 2023
- Computed tomography diagnostic reference levels for adult brain, chest and abdominal examinations: A systematic reviewRadiography, 2021
- National indication-based diagnostic reference level values in computed tomography: Preliminary results from GhanaPhysica Medica, 2021
- CT diagnostic reference levels based on clinical indications: results of a large-scale European surveyEuropean Radiology, 2021
- Update of national diagnostic reference levels for adult CT in Switzerland and assessment of radiation dose reduction since 2010European Radiology, 2019
- Patient dose evaluation in computed tomography: A French national study based on clinical indicationsPhysica Medica, 2019
- Benchmarking adult CT-dose levels to regional and national references using a dose-tracking software: a multicentre experienceInsights into Imaging, 2017
- Material differentiation by dual energy CT: initial experienceEuropean Radiology, 2006
- Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose)European Radiology, 2002