Reem M. Althubaiti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Reem M. Althubaiti has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Abir Bouaoun
Department of Radiological Sciences, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah 21589, Saudi Arabia
3 shared publications - Afnan A. Malaih
Department of Radiologic Sciences, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah 22252, Saudi Arabia
2 shared publications - Rudeinah W. Edreess
Computed Tomography Division, Department of Radiology, King Abdulaziz University Hospital, Jeddah 22252, Saudi Arabia
2 shared publications - Awad Alzahrani
Department of Radiological Sciences, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah 21589, Saudi Arabia
1 shared publication - Lojain Abdulaal
Department of Radiological Sciences, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah 21589, Saudi Arabia
1 shared publication - Meshal Alzahrani
Department of Radiological Sciences, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah 21589, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
- 9 November 2026
- Published by MDPI AG in International Medical Education
- Vol. 5 (4) , 127
Automation Bias in AI-Assisted Simulated Radiotherapy Decision-Making Among Undergraduate Radiological Sciences Students: A Controlled Experimental Study
Background: Artificial intelligence (AI) may support clinical decision-making but introduce automation bias when incorrect recommendations influence users. This study aimed to determine the occurrence of harmful automation bias among undergraduate radiological sciences students during AI-assisted radiotherapy decision-making and to examine the influence of time pressure. Methods: In a controlled experiment, 54 final-year undergraduate radiological sciences students with no prior clinical radiotherapy placement experience completed 20 simulated radiotherapy decision-making scenarios with 13 correct and seven deliberately incorrect AI recommendations (1080 trials). Initial and final responses, AI advice acceptance, confidence, perceived workload, and attitudes toward AI verification were assessed. Students were assigned to time-pressure (n = 26) or no-time-pressure (n = 28) conditions. Harmful automation bias was operationally defined as switching from an initially correct response to an incorrect response matching AI advice. Results: Harmful automation bias occurred in 20/220 eligible trials (9.1%), affecting 15/54 students (27.8%). Incorrect AI advice was followed in 137/378 trials (36.2%). Overall accuracy remained similar before and after AI exposure (75.65% vs. 74.91%; p = 0.289). Time pressure increased workload, but no statistically significant association with harmful automation bias was observed (OR = 0.78; p = 0.654). Lower post-decision confidence was associated with harmful automation bias (OR = 0.599; p = 0.028). No statistically significant difference in harmful automation bias was observed between participants who supported AI verification and those who did not. Conclusions: Harmful automation bias can occur despite stable overall accuracy, suggesting that greater emphasis on critical appraisal, active verification, and independent judgement may be valuable in radiotherapy education.
- 9 November 2026
- Published by MDPI AG in International Medical Education
- Vol. 5 (4) , 127
Open AccessAutomation Bias in AI-Assisted Simulated Radiotherapy Decision-Making Among Undergraduate Radiological Sciences Students: A Controlled Experimental Study
Background: Artificial intelligence (AI) may support clinical decision-making but introduce automation bias when incorrect recommendations influence users. This study aimed to determine the occurrence of harmful automation bias among undergraduate radiological sciences students during AI-assisted radiotherapy decision-making and to examine the influence of time pressure. Methods: In a controlled experiment, 54 final-year undergraduate radiological sciences students with no prior clinical radiotherapy placement experience completed 20 simulated radiotherapy decision-making scenarios with 13 correct and seven deliberately incorrect AI recommendations (1080 trials). Initial and final responses, AI advice acceptance, confidence, perceived workload, and attitudes toward AI verification were assessed. Students were assigned to time-pressure (n = 26) or no-time-pressure (n = 28) conditions. Harmful automation bias was operationally defined as switching from an initially correct response to an incorrect response matching AI advice. Results: Harmful automation bias occurred in 20/220 eligible trials (9.1%), affecting 15/54 students (27.8%). Incorrect AI advice was followed in 137/378 trials (36.2%). Overall accuracy remained similar before and after AI exposure (75.65% vs. 74.91%; p = 0.289). Time pressure increased workload, but no statistically significant association with harmful automation bias was observed (OR = 0.78; p = 0.654). Lower post-decision confidence was associated with harmful automation bias (OR = 0.599; p = 0.028). No statistically significant difference in harmful automation bias was observed between participants who supported AI verification and those who did not. Conclusions: Harmful automation bias can occur despite stable overall accuracy, suggesting that greater emphasis on critical appraisal, active verification, and independent judgement may be valuable in radiotherapy education.
- Open Access
- 18 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (12) , 1897
From Anatomical to Clinical DRLs: Establishing Indication-Based CT Dose Benchmarks in Saudi Arabia
Background: Although diagnostic reference levels (DRLs) based on anatomical regions are widely used in computed tomography (CT) imaging, a clinical-indication-based approach provides a more accurate representation of daily practice and protocol variation. This study aimed to establish typical radiation doses for common CT clinical indications among adult patients at King Abdulaziz University Hospital (KAUH) in Saudi Arabia. Methods: This retrospective cross-sectional study included 298 adult patients who underwent CT examinations between 2020 and 2025 using two dual-source scanners operating in single- and dual-source modes. Demographic data, acquisition parameters, and radiation dose metrics, including CT dose index (CTDIvol) and the dose–length product (DLP), were extracted from scanner consoles. Six clinical indications were analyzed: brain trauma, sinusitis, chest metastases (chest Mets), interstitial lung disease (ILD), abdominopelvic metastases (AbdPel Mets), and hernia. Results: Typical median CTDIvol values in mGy were 36.4 for brain trauma, 3.4 for sinusitis, 4.9 for chest Mets, 5.6 for ILD, 7.2 for AbdPel Mets and hernia. Corresponding DLP values in mGy·cm were 654, 50, 173, 188, 344, and 369, respectively. Brain trauma demonstrated the highest radiation exposure, whereas sinusitis CT showed the lowest. Most values were comparable to or lower than international DRLs. Conclusions: This study provides the first comprehensive clinical-indication-based DRL data in Saudi Arabia beyond anatomical benchmarks, supporting ongoing dose optimization and future national DRL development.
- 18 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (12) , 1897
Open AccessFrom Anatomical to Clinical DRLs: Establishing Indication-Based CT Dose Benchmarks in Saudi Arabia
Background: Although diagnostic reference levels (DRLs) based on anatomical regions are widely used in computed tomography (CT) imaging, a clinical-indication-based approach provides a more accurate representation of daily practice and protocol variation. This study aimed to establish typical radiation doses for common CT clinical indications among adult patients at King Abdulaziz University Hospital (KAUH) in Saudi Arabia. Methods: This retrospective cross-sectional study included 298 adult patients who underwent CT examinations between 2020 and 2025 using two dual-source scanners operating in single- and dual-source modes. Demographic data, acquisition parameters, and radiation dose metrics, including CT dose index (CTDIvol) and the dose–length product (DLP), were extracted from scanner consoles. Six clinical indications were analyzed: brain trauma, sinusitis, chest metastases (chest Mets), interstitial lung disease (ILD), abdominopelvic metastases (AbdPel Mets), and hernia. Results: Typical median CTDIvol values in mGy were 36.4 for brain trauma, 3.4 for sinusitis, 4.9 for chest Mets, 5.6 for ILD, 7.2 for AbdPel Mets and hernia. Corresponding DLP values in mGy·cm were 654, 50, 173, 188, 344, and 369, respectively. Brain trauma demonstrated the highest radiation exposure, whereas sinusitis CT showed the lowest. Most values were comparable to or lower than international DRLs. Conclusions: This study provides the first comprehensive clinical-indication-based DRL data in Saudi Arabia beyond anatomical benchmarks, supporting ongoing dose optimization and future national DRL development.
- Open Access
- 1 May 2026
- Published by MDPI AG in Preprints.org
From Anatomical to Clinical DRLs: Establishing Indication-Based CT Dose Benchmarks in Saudi Arabia
Background: Although Diagnostic Reference Levels (DRLs) based on anatomical regions are widely used in Computed Tomography (CT) imaging, a clinical-indication-based approach provides a more accurate representation of daily practice and protocol variation. This study aimed to establish typical radiation doses for common CT clinical indications among adult patients at King Abdulaziz University Hospital (KAUH) in Saudi Arabia. Methods: This retrospective cross-sectional study included 298 adult patients who underwent CT examinations between 2020 and 2025 using two dual-source scanners operating in single- and dual-source modes. Demographic data, acquisition parameters, and radiation dose metrics, including volume CT dose index (CTDIvol) and the dose–length product (DLP) were extracted from scanner consoles. Six clinical indications were analyzed: brain trauma, sinusitis, chest metastases (chest Mets), interstitial lung disease (ILD), abdominopelvic metastases (AbdPel Mets), and hernia. Results: Typical median CTDIvol values in mGy were 36.4 for brain trauma, 3.4 for sinusitis, 4.9 for chest Mets, 5.6 for ILD, 7.2 for AbdPel Mets and hernia. Corresponding DLP values in mGy·cm were 654, 50, 173, 188, 344, and 369, respectively. Brain trauma demonstrated the highest radiation exposure, whereas sinusitis CT showed the lowest. Most values were comparable to or lower than international DRLs. Conclusions: This study provides the first comprehensive clinical-indication-based DRL data in Saudi Arabia beyond anatomical benchmarks, supporting ongoing dose optimization and future national DRL development.
- 1 May 2026
- Published by MDPI AG in Preprints.org
Open AccessFrom Anatomical to Clinical DRLs: Establishing Indication-Based CT Dose Benchmarks in Saudi Arabia
Background: Although Diagnostic Reference Levels (DRLs) based on anatomical regions are widely used in Computed Tomography (CT) imaging, a clinical-indication-based approach provides a more accurate representation of daily practice and protocol variation. This study aimed to establish typical radiation doses for common CT clinical indications among adult patients at King Abdulaziz University Hospital (KAUH) in Saudi Arabia. Methods: This retrospective cross-sectional study included 298 adult patients who underwent CT examinations between 2020 and 2025 using two dual-source scanners operating in single- and dual-source modes. Demographic data, acquisition parameters, and radiation dose metrics, including volume CT dose index (CTDIvol) and the dose–length product (DLP) were extracted from scanner consoles. Six clinical indications were analyzed: brain trauma, sinusitis, chest metastases (chest Mets), interstitial lung disease (ILD), abdominopelvic metastases (AbdPel Mets), and hernia. Results: Typical median CTDIvol values in mGy were 36.4 for brain trauma, 3.4 for sinusitis, 4.9 for chest Mets, 5.6 for ILD, 7.2 for AbdPel Mets and hernia. Corresponding DLP values in mGy·cm were 654, 50, 173, 188, 344, and 369, respectively. Brain trauma demonstrated the highest radiation exposure, whereas sinusitis CT showed the lowest. Most values were comparable to or lower than international DRLs. Conclusions: This study provides the first comprehensive clinical-indication-based DRL data in Saudi Arabia beyond anatomical benchmarks, supporting ongoing dose optimization and future national DRL development.