Metal ion-mobilizing additives for comprehensive detection of femtomole amounts of phosphopeptides by reversed phase LC-MS
- 16 June 2010
- journal article
- Published by Springer Nature in Amino Acids
- Vol. 41 (2) , 311-320
Abstract
It is hypothesized that metal ion-mediated adsorption of phosphorylated peptides on stationary phases of LC-columns is the major cause for their frequently observed poor detection efficiency in LC-MS. To study this phenomenon in more detail, sample solutions spiked with metal ion-mobilizing additives were analyzed by reversed phase μLC-ICP-MS or nanoLC-ESI-MS. Using μLC-ICP-MS, metal ions were analyzed directly as atomic ions. Using electrospray ionization, either metal ion chelates or phosphopeptide standard mixtures injected in subpicomole amounts were analyzed. Deferoxamine, imidazole, ascorbate, citrate, EDTA, and the tetrapeptide pSpSpSpS were tested as sample additives for the interlinked purposes of metal ion-mobilization and improvement of phosphopeptide recovery. Iron probably represents the major metal ion contamination of reversed phase columns. Based on the certified iron level in LC-grade solvents, a daily metal ion load of >10 pmol was estimated for typical nanoLC flow rates. In addition, phosphopeptide fractions from IMAC columns were identified as source for metal ion contamination of the LC column, as demonstrated for Ga3+-IMAC. The three metal ion-chelating additives, EDTA, citrate and pSpSpSpS, were found to perform best for improving the LC recovery of multiply phosphorylated peptides injected at subpicomole amounts. The benefits of metal ion-mobilizing LC (mimLC) characterized by metal ion complexing sample additives is demonstrated for three different instrumental setups comprising (a) a nanoUPLC-system with direct injection on the analytical column, (b) a nanoLC system with inclusion of a trapping column, and (c) the use of a HPLC-Chip system with integrated trapping and analytical column.Keywords
This publication has 20 references indexed in Scilit:
- Ethylenediaminetetraacetic Acid Increases Identification Rate of Phosphoproteomics in Real Biological SamplesJournal of Proteome Research, 2010
- Citrate Boosts the Performance of Phosphopeptide Analysis by UPLC-ESI-MS/MSJournal of Proteome Research, 2008
- Interaction of Imidazole Containing Hydroxamic Acids with Fe(III): Hydroxamate Versus Imidazole Coordination of the LigandsBioinorganic Chemistry and Applications, 2007
- Identification of class I MHC-associated phosphopeptides as targets for cancer immunotherapyProceedings of the National Academy of Sciences, 2006
- Formation of phosphopeptide‐metal ion complexes in liquid chromatography/electrospray mass spectrometry and their influence on phosphopeptide detectionRapid Communications in Mass Spectrometry, 2005
- Specificity of Immobilized Metal Affinity-Based IMAC/C18 Tip Enrichment of Phosphopeptides for Protein Phosphorylation AnalysisAnalytical Chemistry, 2005
- Phosphoric Acid as a Matrix Additive for MALDI MS Analysis of Phosphopeptides and PhosphoproteinsAnalytical Chemistry, 2004
- Effective treatment of hereditary haemochromatosis with desferrioxamine in selected casesBritish Journal of Haematology, 2003
- Alkaline liquid chromatography/electrospray ionization skimmer collision‐induced dissociation mass spectrometry for phosphopeptide screeningRapid Communications in Mass Spectrometry, 2001
- Selective adsorption of phosphoproteins on gel-immobilized ferric chelateBiochemistry, 1986