IONIZING RADIATION AND VOLUMETRIC MAMMOGRAPHIC DENSITY
Open Access
- 1 January 2022
- journal article
- research article
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 35 (5) , 635-649
Abstract
Objectives: Mammographic density (MD) refers to the percentage of dense tissue of an entire breast and was proposed to be used as a surrogate marker for breast cancer. High-dose ionizing radiation (IR) has been recognized as a breast cancer risk factor. The aim of our study was to investigate association between lifetime low dose ionizing radiation (LDIR) and MD. Material and Methods: A cross-sectional study included 467 women aged 40-60 years who underwent screening mammography in Lodz, Poland. The digital mammography examination of the breasts included both craniocaudal and mediolateral oblique views. The volumetric breast density (VBD) (%) and fibrograndular tissue volume (FG) (cm3) were deter-mined based on the analysis of mammographic image ("for processing") using Volpara Imaging Software. The exposure to IR was estimated for each individual, based on the data from interviews about diagnostic or therapeutic medical procedures performed in the area of the neck, chest, abdomen and spine, which involved X-rays and gamma rays and the data about the doses derived from literature. Linear and logistic regression were fitted with VBD and FG as the outcomes and organ breast dose, effective dose and number of mammographies as the determinants, adjusted for major confounders. Results: The analyses showed no association between VBD or FG and the breast organ dose or the effective dose. The only significant finding ob-served concerned the association between the number of mammographies and the FG volume with beta coefficient: 0.028 (95% CI: 0.012-0.043), and predicted mean FG volume >13.4 cm3 among the women with >3 mammographies when compared to those with none. Conclusions: This study does not, in general, provide support for the positive association between LDIR and MD. The weak association of the FG volume with the number of mammographies warrants further verification in larger independent studies. Int J Occup Med Environ Health. 2022;35(5):635 - 49Keywords
This publication has 23 references indexed in Scilit:
- Comparing Visually Assessed BI-RADS Breast Density and Automated Volumetric Breast Density Software: A Cross-Sectional Study in a Breast Cancer Screening SettingPLOS ONE, 2015
- On effective dose for radiotherapy based on doses to nontarget organs and tissuesMedical Physics, 2015
- Re: Breast Tissue Composition and Susceptibility to Breast CancerJNCI: Journal of the National Cancer Institute, 2010
- Comparison of Acquisition Parameters and Breast Dose in Digital Mammography and Screen-Film Mammography in the American College of Radiology Imaging Network Digital Mammographic Imaging Screening TrialAmerican Journal of Roentgenology, 2010
- Strong Evidence of a Genetic Determinant for Mammographic Density, a Major Risk Factor for Breast CancerCancer Research, 2007
- Preventing or reducing late side effects of radiation therapy: radiobiology meets molecular pathologyNature Reviews Cancer, 2006
- Breast Density and Parenchymal Patterns as Markers of Breast Cancer Risk: A Meta-analysisCancer Epidemiology, Biomarkers & Prevention, 2006
- Estrogen-Plus-Progestin Use and Mammographic Density in Postmenopausal Women: Women's Health Initiative Randomized TrialJNCI: Journal of the National Cancer Institute, 2005
- Cellular Mechanisms for Low-Dose Ionizing Radiation–Induced Perturbation of the Breast Tissue MicroenvironmentCancer Research, 2005
- Quantitative Classification of Mammographic Densities and Breast Cancer Risk: Results From the Canadian National Breast Screening StudyJNCI: Journal of the National Cancer Institute, 1995