Joanna Domienik-Andrzejewska
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Joanna Domienik-Andrzejewska has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Mateusz Mirowski
Nofer Institute of Occupational Medicine, Św. Teresy od Dzieciątka Jezus 8, 91-348 Łódz, Poland
4 shared publications - Eleftheria Carinou
Greek Atomic Energy Commission, Agia Paraskevi, Attiki 15344, Greece
2 shared publications - Jérémie Dabin
Belgian Nuclear Research Centre (SCK CEN), Mol, Belgium
2 shared publications - Michał Biegała
Department of Medical Imaging Technology, Faculty of Medicine, Medical University of Lodz, Lodz, Poland
2 shared publications Paweł Kałużny
Nofer Inst Occupat Med, Dept Environm Epidemiol, Lodz, Poland
2 shared publications- Teresa Jakubowska
Department of Medical Imaging Technology, Medical University of Lodz, ul. Lindleya 6, 90-131 Łódź, Poland
2 shared publications
Latest Publications
- 2 December 2025
- Published by Elsevier in Physica Medica
- Vol. 140, 105685
Considerations on dose constraints in interventional cardiology – first approach to establishing dose constraints
- 2 December 2025
- Published by Elsevier in Physica Medica
- Vol. 140, 105685
Considerations on dose constraints in interventional cardiology – first approach to establishing dose constraints
- Open Access
- 19 August 2025
- Published by Termedia Sp. z.o.o. in Archives of Medical Science
- Vol. 21 (4) , 1654-1657
Exposure of pregnant women to ionizing radiation during interventional radiology and computed tomography procedures
In the measurements of exposure of pregnant women, highly sensitive thermoluminescent detectors (TLDs type MCP-N manufactured by Radcard, Poland) were used [10, 11]. Calibration of TL detectors for measurements with an anthropomorphic phantom was performed in the air kerma (Ka) unit using the ISO N-80 reference energy spectrum [12] according to procedures developed at NIOM. An overall 20% measurement uncertainty was estimated, and it is mainly due to the energy dependence of TL detectors.
- 19 August 2025
- Published by Termedia Sp. z.o.o. in Archives of Medical Science
- Vol. 21 (4) , 1654-1657
Open AccessExposure of pregnant women to ionizing radiation during interventional radiology and computed tomography procedures
In the measurements of exposure of pregnant women, highly sensitive thermoluminescent detectors (TLDs type MCP-N manufactured by Radcard, Poland) were used [10, 11]. Calibration of TL detectors for measurements with an anthropomorphic phantom was performed in the air kerma (Ka) unit using the ISO N-80 reference energy spectrum [12] according to procedures developed at NIOM. An overall 20% measurement uncertainty was estimated, and it is mainly due to the energy dependence of TL detectors.
- Open Access
- 13 December 2024
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 37 (6) , 569-580
Patient and physician exposure to X-rays at pediatric interventional cardiology – from world to Poland
Ionizing radiation is considered as a harmful factor to health. However, X‑rays are widely used in diagnostic and therapeutic procedures such as those performed during cardiac interventions. Their use is particularly invaluable in saving life procedures when the risk of adverse effects of...
- 13 December 2024
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 37 (6) , 569-580
Open AccessPatient and physician exposure to X-rays at pediatric interventional cardiology – from world to Poland
Ionizing radiation is considered as a harmful factor to health. However, X‑rays are widely used in diagnostic and therapeutic procedures such as those performed during cardiac interventions. Their use is particularly invaluable in saving life procedures when the risk of adverse effects of...
- Open Access
- 11 September 2024
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 37 (4) , 403-410
Exposure to ionizing radiation of medical staff performing vascular and interventional radiology procedures
Objectives: Vascular and interventional radiology procedures are characterized by high exposure of personnel to ionizing radiation. This study assessed the exposure of medical personnel to ionizing radiation during vascular radiology and mechanical thrombectomy procedures. Material and...
- 11 September 2024
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 37 (4) , 403-410
Open AccessExposure to ionizing radiation of medical staff performing vascular and interventional radiology procedures
Objectives: Vascular and interventional radiology procedures are characterized by high exposure of personnel to ionizing radiation. This study assessed the exposure of medical personnel to ionizing radiation during vascular radiology and mechanical thrombectomy procedures. Material and...
- Open Access
- 29 December 2023
- Published by Nofer Institute of Occupational Medicine in Medycyna Pracy
- Vol. 74 (6) , 527-539
Individual dosimetry as an element of health prevention for employees exposed to ionizing radiation
The paper presents the current radiation protection standards, in line with the recommendations of the International Commission on Radiological Protection (ICRP), and their evolution over the years based on new knowledge about the biological effects of ionizing radiation and the changing attitude...
- 29 December 2023
- Published by Nofer Institute of Occupational Medicine in Medycyna Pracy
- Vol. 74 (6) , 527-539
Open AccessIndividual dosimetry as an element of health prevention for employees exposed to ionizing radiation
The paper presents the current radiation protection standards, in line with the recommendations of the International Commission on Radiological Protection (ICRP), and their evolution over the years based on new knowledge about the biological effects of ionizing radiation and the changing attitude...
- Open Access
- 29 March 2022
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 35 (5) , 549-560
The effect of lead free cap on the doses of ionizing radiation to the head of interventional cardiologists working in haemodynamic room
Objectives: The study aim was to analyse the influence of the lead free cap on doses received by interventional cardiologists. The impact of lead free cap on doses to the head were evaluated in number of studies. As different methods used to assess the attenuation properties of protective cap...
- 29 March 2022
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 35 (5) , 549-560
Open AccessThe effect of lead free cap on the doses of ionizing radiation to the head of interventional cardiologists working in haemodynamic room
Objectives: The study aim was to analyse the influence of the lead free cap on doses received by interventional cardiologists. The impact of lead free cap on doses to the head were evaluated in number of studies. As different methods used to assess the attenuation properties of protective cap...
- Open Access
- 26 February 2022
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 61 (2) , 293-300
Occupational exposure to physicians working with a Zero-Gravity™ protection system in haemodynamic and electrophysiology labs and the assessment of its performance against a standard ceiling suspended shield
A two centre clinical study was performed to analyse exposure levels of cardiac physicians performing electrophysiology and haemodynamic procedures with the use of state of the art Zero-Gravity™ radiation protective system (ZG). The effectiveness of ZG was compared against the commonly used ceiling suspended lead shield (CSS) in a haemodynamic lab. The operator’s exposure was assessed using thermoluminescent dosimeters (TLDs) during both ablation (radiofrequency ablation (RFA) and cryoablation (CRYA)) and angiography and angioplasty procedures (CA/PCI). The dosimeters were placed in multiple body regions: near the left eye, on the left side of the neck, waist and chest, on both hands and ankles during each measurement performed with the use of ZG. In total 29 measurements were performed during 105 procedures. To compare the effectiveness of ZG against CSS an extra 80 measurements were performed with the standard lead apron, thyroid collar and ceiling suspended lead shield during CA/PCI procedures. For ZG, the upper values for the average eye lens and whole body doses per procedure were 4 µSv and 16 µSv for the left eye lens in electrophysiology lab (with additionally used CSS) and haemodynamic lab (without CSS), respectively, and about 10 µSv for the remaining body parts (neck, chest and waist) in both labs. The skin doses to hands and ankles non-protected by the ZG were 5 µSv for the most exposed left finger and left ankle in electrophysiology lab, while in haemodynamic lab 150 µSv and 17 µSv, respectively. The ZG performance was 3 times (p < 0.05) and at least 15 times (p < 0.05) higher for the eye lenses and thoracic region, respectively, compared to CSS (with dosimeters on the apron/collar). However, when only ZG was used slightly higher normalised doses were observed for the left finger compared to CSS (5.88e − 2 Sv/Gym2 vs. 4.31 e − 2 Sv/Gym2, p = 0.016). The study results indicate that ZG performance is superior to CSS. It can be simultaneously used with the ceiling suspended lead shield to ensure the protection to the hands as long as this is not obstructive for the work.
- 26 February 2022
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 61 (2) , 293-300
Open AccessOccupational exposure to physicians working with a Zero-Gravity™ protection system in haemodynamic and electrophysiology labs and the assessment of its performance against a standard ceiling suspended shield
A two centre clinical study was performed to analyse exposure levels of cardiac physicians performing electrophysiology and haemodynamic procedures with the use of state of the art Zero-Gravity™ radiation protective system (ZG). The effectiveness of ZG was compared against the commonly used ceiling suspended lead shield (CSS) in a haemodynamic lab. The operator’s exposure was assessed using thermoluminescent dosimeters (TLDs) during both ablation (radiofrequency ablation (RFA) and cryoablation (CRYA)) and angiography and angioplasty procedures (CA/PCI). The dosimeters were placed in multiple body regions: near the left eye, on the left side of the neck, waist and chest, on both hands and ankles during each measurement performed with the use of ZG. In total 29 measurements were performed during 105 procedures. To compare the effectiveness of ZG against CSS an extra 80 measurements were performed with the standard lead apron, thyroid collar and ceiling suspended lead shield during CA/PCI procedures. For ZG, the upper values for the average eye lens and whole body doses per procedure were 4 µSv and 16 µSv for the left eye lens in electrophysiology lab (with additionally used CSS) and haemodynamic lab (without CSS), respectively, and about 10 µSv for the remaining body parts (neck, chest and waist) in both labs. The skin doses to hands and ankles non-protected by the ZG were 5 µSv for the most exposed left finger and left ankle in electrophysiology lab, while in haemodynamic lab 150 µSv and 17 µSv, respectively. The ZG performance was 3 times (p < 0.05) and at least 15 times (p < 0.05) higher for the eye lenses and thoracic region, respectively, compared to CSS (with dosimeters on the apron/collar). However, when only ZG was used slightly higher normalised doses were observed for the left finger compared to CSS (5.88e − 2 Sv/Gym2 vs. 4.31 e − 2 Sv/Gym2, p = 0.016). The study results indicate that ZG performance is superior to CSS. It can be simultaneously used with the ceiling suspended lead shield to ensure the protection to the hands as long as this is not obstructive for the work.
- Open Access
- 1 January 2022
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 35 (5) , 635-649
IONIZING RADIATION AND VOLUMETRIC MAMMOGRAPHIC DENSITY
Objectives: Mammographic density (MD) refers to the percentage of dense tissue of an entire breast and was proposed to be used as a surrogate marker for breast cancer. High-dose ionizing radiation (IR) has been recognized as a breast cancer risk factor. The aim of our study was to investigate association between lifetime low dose ionizing radiation (LDIR) and MD. Material and Methods: A cross-sectional study included 467 women aged 40-60 years who underwent screening mammography in Lodz, Poland. The digital mammography examination of the breasts included both craniocaudal and mediolateral oblique views. The volumetric breast density (VBD) (%) and fibrograndular tissue volume (FG) (cm3) were deter-mined based on the analysis of mammographic image ("for processing") using Volpara Imaging Software. The exposure to IR was estimated for each individual, based on the data from interviews about diagnostic or therapeutic medical procedures performed in the area of the neck, chest, abdomen and spine, which involved X-rays and gamma rays and the data about the doses derived from literature. Linear and logistic regression were fitted with VBD and FG as the outcomes and organ breast dose, effective dose and number of mammographies as the determinants, adjusted for major confounders. Results: The analyses showed no association between VBD or FG and the breast organ dose or the effective dose. The only significant finding ob-served concerned the association between the number of mammographies and the FG volume with beta coefficient: 0.028 (95% CI: 0.012-0.043), and predicted mean FG volume >13.4 cm3 among the women with >3 mammographies when compared to those with none. Conclusions: This study does not, in general, provide support for the positive association between LDIR and MD. The weak association of the FG volume with the number of mammographies warrants further verification in larger independent studies. Int J Occup Med Environ Health. 2022;35(5):635 - 49
- 1 January 2022
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 35 (5) , 635-649
Open AccessIONIZING RADIATION AND VOLUMETRIC MAMMOGRAPHIC DENSITY
Objectives: Mammographic density (MD) refers to the percentage of dense tissue of an entire breast and was proposed to be used as a surrogate marker for breast cancer. High-dose ionizing radiation (IR) has been recognized as a breast cancer risk factor. The aim of our study was to investigate association between lifetime low dose ionizing radiation (LDIR) and MD. Material and Methods: A cross-sectional study included 467 women aged 40-60 years who underwent screening mammography in Lodz, Poland. The digital mammography examination of the breasts included both craniocaudal and mediolateral oblique views. The volumetric breast density (VBD) (%) and fibrograndular tissue volume (FG) (cm3) were deter-mined based on the analysis of mammographic image ("for processing") using Volpara Imaging Software. The exposure to IR was estimated for each individual, based on the data from interviews about diagnostic or therapeutic medical procedures performed in the area of the neck, chest, abdomen and spine, which involved X-rays and gamma rays and the data about the doses derived from literature. Linear and logistic regression were fitted with VBD and FG as the outcomes and organ breast dose, effective dose and number of mammographies as the determinants, adjusted for major confounders. Results: The analyses showed no association between VBD or FG and the breast organ dose or the effective dose. The only significant finding ob-served concerned the association between the number of mammographies and the FG volume with beta coefficient: 0.028 (95% CI: 0.012-0.043), and predicted mean FG volume >13.4 cm3 among the women with >3 mammographies when compared to those with none. Conclusions: This study does not, in general, provide support for the positive association between LDIR and MD. The weak association of the FG volume with the number of mammographies warrants further verification in larger independent studies. Int J Occup Med Environ Health. 2022;35(5):635 - 49
- Open Access
- 16 October 2019
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 32 (5) , 663-675
Occupational exposure to ionizing radiation and lens opacity in interventional cardiologists
Objectives: Interventional cardiologists (ICs) are occupationally exposed to low or moderate doses of ionizing radiation from repeated exposures. It is not clear whether these occupational conditions may affect their eye lens. Therefore, the risk of radiation-induced cataract in the cohort of...
- 16 October 2019
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 32 (5) , 663-675
Open AccessOccupational exposure to ionizing radiation and lens opacity in interventional cardiologists
Objectives: Interventional cardiologists (ICs) are occupationally exposed to low or moderate doses of ionizing radiation from repeated exposures. It is not clear whether these occupational conditions may affect their eye lens. Therefore, the risk of radiation-induced cataract in the cohort of...
- 1 February 2018
- Published by Elsevier in Physica Medica
- Vol. 46, 67-74
Feasibility of setting up generic alert levels for maximum skin dose in fluoroscopically guided procedures
- 1 February 2018
- Published by Elsevier in Physica Medica
- Vol. 46, 67-74
Feasibility of setting up generic alert levels for maximum skin dose in fluoroscopically guided procedures