Incorporation of Time-of-Flight Information Reduces Metal Artifacts in Simultaneous Positron Emission Tomography/Magnetic Resonance Imaging
- 1 July 2015
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 50 (7) , 423-429
Abstract
Objectives This study aimed to describe and evaluate the influence of time-of-flight (TOF) information on metal artifact reduction in positron emission tomography (PET) image quality in clinical simultaneous PET/magnetic resonance (MR) scanning. Materials and Methods A total of 7 patients with various malignant tumors were included and underwent a PET/MR examination after standard PET/computed tomography. Baseline TOF and non-TOF PET images were reconstructed. Next, the TOF and non-TOF PET reconstructions were repeated after the introduction of artificial signal voids in the attenuation map to simulate metal artifacts of various sizes in a range of locations. Three different sizes of signal voids were inserted in the attenuation maps for each location of interest: over the maxilla, humeral head, chest, sternum, thoracic and lumbar spine, as well as the femoral head to replicate clinically relevant metal artifacts. The reconstructed images with the artifacts were then compared with the baseline reconstructed images. The mean percentage error in a region of interest surrounding the simulated artifact was used to compare between TOF and non-TOF images. Further comparison between TOF and non-TOF images was performed using histogram analysis. Results In all cases, the mean percentage error in a region of interest surrounding the simulated artifact was reduced when TOF information was included in the reconstruction. The inclusion of TOF also changes the distribution of smaller errors away from the origin of the artifact. In some anatomical regions, an increase in the number of small errors was noted with TOF, although the differences with non-TOF were minimal. Conclusions Positron emission tomographic imaging benefits from the integration of TOF information in simultaneous PET/MR. The inclusion of TOF information in simultaneous PET/MR imaging reduces errors related to metal artifacts at the site of the artifact.Keywords
This publication has 26 references indexed in Scilit:
- Clinical applications of PET/MRI: current status and future perspectivesDiagnostic and Interventional Radiology, 2014
- Individually Differentiated Serotonergic Raphe Nuclei Measured with Brain PET/MR ImagingRadiology, 2014
- Principles of PET/MR ImagingJournal of Nuclear Medicine, 2014
- Combined PET/MR imaging in neurology: MR-based attenuation correction implies a strong spatial bias when ignoring boneNeuroImage, 2014
- Comparison of 4-Class and Continuous Fat/Water Methods for Whole-Body, MR-Based PET Attenuation CorrectionIEEE Transactions on Nuclear Science, 2013
- Evaluation of an Atlas-Based PET Head Attenuation Correction Using PET/CT & MR Patient DataIEEE Transactions on Nuclear Science, 2013
- Hybrid PET/MR Imaging of the Heart: Potential, Initial Experiences, and Future ProspectsJournal of Nuclear Medicine, 2013
- Oncologic PET/MRI, Part 1: Tumors of the Brain, Head and Neck, Chest, Abdomen, and PelvisJournal of Nuclear Medicine, 2012
- Towards quantitative PET/MRI: a review of MR-based attenuation correction techniquesEuropean Journal of Nuclear Medicine and Molecular Imaging, 2008
- PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficientsEuropean Journal of Nuclear Medicine and Molecular Imaging, 2002