Characterization of Nanopore Electrode Structures as Basis for Amplified Electrochemical Assays
- 19 October 2006
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 18 (19-20) , 1929-1936
Abstract
A nanopore electrode structure was fabricated consisting of ensembles of nanopores with separately addressable electrodes at the pore bottoms and the rims. A metal/insulator/metal layer structure allowed for adjusting the spacing between the bottom and rim electrodes to be in the range of about 200 nm. Pore diameters varied between 200 and 800 nm. The electrochemical properties of this electrode structure and its perspectives for applications in bioelectronics were studied using cyclic voltammetry and chronoamperometry along with high‐resolution scanning electrochemical microscopy (SECM) in constant‐distance mode. It was possible to visualize the electrochemical activity of a single nanometric electrode using high‐resolution SECM in a combination of sample‐generation‐tip‐collection mode and positive feedback mode. The SECM images suggested an influence of the unbiased rim electrode on redox amplification which was used as a basis for evaluating the feasibility of current amplification by means of redox cycling between the bottom and rim electrodes. Amplification factors superior to those obtained with interdigitated array electrodes could be demonstrated.Keywords
This publication has 19 references indexed in Scilit:
- Integrated Nanoparticle–Biomolecule Hybrid Systems: Synthesis, Properties, and ApplicationsAngewandte Chemie International Edition, 2004
- Determination of p-aminophenol and catecholamines at picomolar concentrations based on recycling enzyme amplificationAnalytica Chimica Acta, 1995
- Measurement of nanomolar diphenols by substrate recycling coupled to a pH-sensitive electrodeAnalytical and Bioanalytical Chemistry, 1995
- Cascade-like exponential substrate amplification in enzyme sensorsBiosensors and Bioelectronics, 1995
- "Wired" Enzyme Electrodes for Amperometric Determination of Glucose or Lactate in the Presence of Interfering SubstancesAnalytical Chemistry, 1994
- Zeptomole detection limit for alkaline phosphatase using 4-aminophenylphosphate, amperometric detection, and an optimal buffer systemAnalytica Chimica Acta, 1993
- Comparison of methods for following alkaline phosphatase catalysis: Spectrophotometric versus amperometric detectionAnalytical Biochemistry, 1991
- Polypyrrole, a new possibility for covalent binding of oxidoreductases to electrode surfaces as a base for stable biosensorsSensors and Actuators B: Chemical, 1990
- A Biosensor for ADP with Internal Substrate AmplificationAnalytical Letters, 1987
- Filar electrodes: steady-state currents and spectroelectrochemistry at twin interdigitated electrodesAnalytical Chemistry, 1985