Martin Stelzle has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Moving the solid phase: a platform technology for cartridge based sandwich immunoassays

    by Raiah Gottheil, Nadja Baur, Holger Becker, Gorden Link, Dimitri Maier, Nicole Schneiderhan-Marra, Martin Stelzle

    We report on a cartridge based platform for complex immunoassay formats that allows for flexible adaption of individual steps. It is a sample-to-answer system which is quantitative as well as sensitive. The target molecules are detected through a magnetic bead-based fluorescence sandwich immunoassay. The beads both constitute the solid phase for immobilizing capture molecules and are used for magnetic field activated incubation. The injection molded cartridge comprises several chambers separated by capillary valves. Chambers contain the assay reagents, through which the beads are manipulated via externally applied magnetic fields. Active incubation is made possible by assembling the beads into microstirrers and systematically scanning through a chamber. The beads are transported by focusing them to form an aggregate which subsequently is dragged through the valves. Once the aggregate enters a chamber, it is re-dispersed and magnetic actuation is used to re-assemble the beads into microstirrers. The assay protocol involves an incubation of sample with antibody coated magnetic beads, followed by steps for washing or separation, labeling with fluorescent detection antibody and finally fluorescence detection. An interleukin-8 assay served as a model for evaluating the system and a concentration as low as 5 pg/mL (0.625 pM) was successfully detected. The platform shows potential to be developed into a diagnostic tool to be used in a point-of-care testing (PoCT) environment.


  • A method for patterned in situ biofunctionalization in injection-molded microfluidic devices

    by Julia Schütte, Christian Freudigmann, Karin Benz, Jan Böttger, Rolf Gebhardt, Martin Stelzle

    We developed a method to modify the surface in injection molded polymer microdevices prior to bonding and to pattern biomolecules in the completed microsystem in situ by a sequence of simple perfusion steps directly before utilization of the device. This method is compatible with production technology such as injection molding and bonding processes currently employed in the fabrication of polymer microsystems. It solves the problem of the inherent incompatibility of biomolecules with microfabrication technology as it allows for the biofunctionalization step to be performed after completion of the microsystem. Injection molded cyclic olefin copolymer (COC) microfluidic chips were modified by irradiating the surface with UV-light at λ = 185 nm. This results in the formation of stable acidic groups which were further modified by binding of the extracellular matrix protein collagen type I. Non-irradiated surfaces were modified by binding of Pluronic® F-127 to become non-adhesive. Density of acid groups decreases to 50% within 45 days and to 25% within 19 weeks after irradiation. However, even then the remaining density of functional groups was shown to be sufficient to bind proteins and promote cell adhesion. Selective adhesion of primary hepatocytes on surfaces patterned by UV-irradiation and a biofunctional coating with collagen type I were demonstrated in injection molded microsystems.


  • Localized Functional Chemical Stimulation of TE 671 Cells Cultured on Nanoporous Membrane by Calcein and Acetylcholine

    by Susanne Zibek, Alfred Stett, Peter Koltay, Min Hu, Roland Zengerle, Wilfried Nisch, Martin Stelzle


  • Characterization of Nanopore Electrode Structures as Basis for Amplified Electrochemical Assays

    by Sebastian Neugebauer, Ulrich Müller, Theobald Lohmüller, Joachim P. Spatz, Martin Stelzle, Wolfgang Schuhmann

    A nanopore electrode structure was fabricated consisting of ensembles of nanopores with separately addressable electrodes at the pore bottoms and the rims. A metal/insulator/metal layer structure allowed for adjusting the spacing between the bottom and rim electrodes to be in the range of about 200 nm. Pore diameters varied between 200 and 800 nm. The electrochemical properties of this electrode structure and its perspectives for applications in bioelectronics were studied using cyclic voltammetry and chronoamperometry along with high‐resolution scanning electrochemical microscopy (SECM) in constant‐distance mode. It was possible to visualize the electrochemical activity of a single nanometric electrode using high‐resolution SECM in a combination of sample‐generation‐tip‐collection mode and positive feedback mode. The SECM images suggested an influence of the unbiased rim electrode on redox amplification which was used as a basis for evaluating the feasibility of current amplification by means of redox cycling between the bottom and rim electrodes. Amplification factors superior to those obtained with interdigitated array electrodes could be demonstrated.


  • Accumulation and trapping of hepatitis A virus particles by electrohydrodynamic flow and dielectrophoresis

    by Frank Grom, Jörg Kentsch, Torsten Müller, Thomas Schnelle, Martin Stelzle

    Hepatitis A virus particles (d = 27 nm) were successfully accumulated and trapped in a microfluidic system by means of a combination of electrohydrodynamic flow and dielectrophoretic forces. Electric fields were generated in a field cage consisting of eight microelectrodes. In addition, high medium conductance (0.3 S/m) resulted in sufficient Joule heating and the corresponding spatial variation of temperature, density, and permittivity to induce electrohydrodynamic flow in the vicinity of the field cage. Flow vortices transport particles toward the center of the field cage, where dielectrophoretic forces cause permanent entrapment and particle aggregation. Spatial distribution of temperature, density, and permittivity as well as resulting flow patterns were modeled numerically and are in good agreement with experimental results. This accumulation scheme might be applicable to sample concentration enhancement in biosensor applications.


  • Microdevices for manipulation and accumulation of micro‐ and nanoparticles by dielectrophoresis

    by Manfried Dürr, Jörg Kentsch, Torsten Müller, Thomas Schnelle, Martin Stelzle

    Microfluidic devices with three‐dimensional (3‐D) arrays of microelectrodes embedded in microchannels have been developed to study dielectrophoretic forces acting on synthetic micro‐ and nanoparticles. In particular, so‐called deflector structures were used to separate particles according to their size and to enable accumulation of a fraction of interest into a small sample volume for further analysis. Particle velocity within the microchannels was measured by video microscopy and the hydrodynamic friction forces exerted on deflected particles were determined according to Stokes law. These results lead to an absolute measure of the dielectrophoretic forces and allowed for a quantitative test of the underlying theory. In summary, the influence of channel height, particle size, buffer composition, electric field, strength and frequency on the dielectrophoretic force and the effectiveness of dielectrophoretic deflection structures were determined. For this purpose, microfluidic devices have been developed comprising pairs of electrodes extending into fluid channels on both top and bottom side of the microfluidic channels. Electrodes were aligned under angles varying from 0 to 75° with respect to the direction of flow. Devices with channel height varying between 5 and 50 μm were manufactured. Fabrication involved a dedicated bonding technology using a mask aligner and UV‐curing adhesive. Particles with radius ranging from 250 nm to 12 μm were injected into the channels using aqueous buffer solutions.


  • On-chip electrophoretic accumulation of DNA oligomers and streptavidin

    by Martin Stelzle, Manfried Dürr, Michael Cieplik, Wilfried Nisch