Study of the Feasible Size of a Bone Conduction Implant Transducer in the Temporal Bone
Authors:
- Sabine ReinfeldtSRSabine Reinfeldt
- Per ÖstliPÖPer Östli
- Bo HåkanssonBHBo Håkansson
- Hamidreza TaghaviHTHamidreza Taghavi
- Måns Eeg-OlofssonMEMåns Eeg-Olofsson
- Joacim StalforsJSJoacim Stalfors
- 1 April 2015
- journal article
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 36 (4) , 631-637
Abstract
The aim was to assess the temporal bone volume to determine the suitable size and position of a bone conduction implant (BCI) transducer. A BCI transducer needs to be sufficiently small to fit in the mastoid portion of the temporal bone for a majority of patients. The anatomical geometry limits both the dimension of an implanted transducer and its positions in the temporal bone to provide a safe and simple surgery. Computed tomography (CT) scans of temporal bones from 22 subjects were virtually reconstructed. With an algorithm in MATLAB, the maximum transducer diameter as function of the maximum transducer depth in the temporal bone, and the most suitable position were calculated in all subjects. An implanted transducer diameter of 16 mm inserted at a depth of 4 mm statistically fitted 95% of the subjects. If changing the transducer diameter to 12 mm, a depth of 6 mm would fit in 95% of the subjects. The most suitable position was found to be around 20 mm behind the ear canal. The present BCI transducer casing, used in ongoing clinical trials, was designed from the results in this study, demonstrating that the present BCI transducer casing (largest diameter [diagonal]: 15.5 mm, height: 6.4 mm) will statistically fit more than 95% of the subjects. Hence, the present BCI transducer is concluded to be sufficiently small to fit most normal-sized temporal bones and should be placed approximately 20 mm behind the ear canal.Keywords
This publication has 15 references indexed in Scilit:
- Analysis and Design of RF Power and Data Link Using Amplitude Modulation of Class-E for a Novel Bone Conduction ImplantIEEE Transactions on Biomedical Engineering, 2012
- Assessment of More Than 1,000 Implanted Percutaneous Bone Conduction DevicesOtology & Neurotology, 2012
- Implant survival rate in bone-anchored hearing aid users: long-term resultsThe Journal of Laryngology & Otology, 2011
- A novel bone conduction implant (BCI): Engineering aspects and pre-clinical studiesInternational Journal of Audiology, 2010
- Complications of bone-anchored hearing aid implantationThe Journal of Laryngology & Otology, 2009
- Percutaneous Versus Transcutaneous Bone Conduction Implant SystemOtology & Neurotology, 2008
- Bone-Conducted Sound: Physiological and Clinical AspectsOtology & Neurotology, 2005
- The balanced electromagnetic separation transducer: A new bone conduction transducerThe Journal of the Acoustical Society of America, 2003
- Bone-anchored hearing aidsOtolaryngologic Clinics of North America, 2001
- Resonance frequencies of the human skull in vivoThe Journal of the Acoustical Society of America, 1994