One‐Year Results of a Prospective Multicenter Study on Brånemark System® Implants with a TiUnite™ Surface
Authors:
- Bertil FribergBFBertil Friberg
- Christer DahlinCDChrister Dahlin
- Göran WidmarkGWGöran Widmark
- Pär‐Olov ÖstmanPÖPär‐Olov Östman
- Camilla BillströmCBCamilla Billström
- 1 June 2005
- journal article
- clinical trial
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 7 (s1) , s70-s75
Abstract
Background: A moderately rough surface implant (TiUnite™, Nobel Biocare AB, Göteborg, Sweden) was introduced in 2000. Laboratory studies and some clinical studies have demonstrated excellent bone response in the early healing phase.Purpose: The aim of this prospective multicenter study was to follow a large number of consecutively treated patients using Brånemark System® implants with the TiUnite surface. The current report constitutes the 1‐year data of a planned 3‐year study.Materials and Methods: Originally, the study comprised 43 surgeons from 22 centers in Sweden, Norway, and Finland. Five centers were excluded from the study because of poor compliance. Thus, 187 patients treated with 478 TiUnite implants were followed during 1 year of function. The majority of implants were inserted in maxillae (357 implants), and 78 of the implant sites were assigned the quality 4 figure. Radiographic evaluations were performed.Results: Five implants were lost up to and including the 1‐year follow‐up, revealing implant cumulative survival rates of 98.6% and 100% for maxillae and mandibles, respectively. Three implants failed in quality 4 bone (3.8%). The mean marginal bone resorption at the end of the study period was 1.4 mm. The number of withdrawals of patients during the first year was high (19.3%).Conclusion: The present investigation showed a high implant cumulative survival rate of 98.9%. Values of marginal bone resorption were within normal ranges. No adverse effects of the TiUnite surface were reported, and complications during the study period were few and similar to those reported for the turned implant surface. However, the high number of excluded patients and the relatively high number of withdrawals must be observed and considered when interpreting data.Keywords
This publication has 9 references indexed in Scilit:
- Mk III: A Third Generation of the Self‐Tapping Brånemark System® Implant, Including the New Stargrip Internal Grip Design. A 1‐Year Prospective Four‐Center StudyClinical Implant Dentistry and Related Research, 2003
- Immediate Occlusal Loading of Brånemark TiUnite™ Implants Placed Predominantly in Soft Bone: 1‐Year Results of a Prospective Clinical StudyClinical Implant Dentistry and Related Research, 2003
- Immediate Occlusal Loading of Brånemark Implants Applied in Various Jawbone Regions: A Prospective, 1‐Year Clinical StudyClinical Implant Dentistry and Related Research, 2001
- Brånemark Implants and Osteoporosis: A Clinical Exploratory StudyClinical Implant Dentistry and Related Research, 2001
- On Cutting Torque Measurements during Implant Placement: A 3‐Year Clinical Prospective StudyClinical Implant Dentistry and Related Research, 1999
- Biological factors contributing to failures of osseointegrated oral implants, (I). Success criteria and epidemiologyEuropean Journal of Oral Sciences, 1998
- Mk II: the self‐tapping Brånemark implant: 5‐year results of a prospective 3‐center studyClinical Oral Implants Research, 1997
- The Excessive Loss of Branemark Fixtures in Type IV Bone: A 5‐Year AnalysisJournal of Periodontology, 1991
- A 15-year study of osseointegrated implants in the treatment of the edentulous jawInternational Journal of Oral Surgery, 1981