A Straightforward Quadrature Signal Generator for Single-Phase SOGI-PLL With Low Susceptibility to Grid Harmonics
- 14 July 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 69 (7) , 6997-7007
Abstract
Suppressing the negative effects of grid voltage harmonics on the estimated frequency of a phase-locked loop (PLL) is a challenge in literature. This article proposes an easy-to-implement quadrature signal generator (QSG) to attenuate the oscillations on the estimated frequency in single-phase grid-connected inverters, which use second-order generalized integrator (SOGI)-PLL. It is shown that SOGI exerts a stronger filtering effect in generating the quadrature signal than the in-phase signal. Against this background, in this work, a modified integrator is introduced into the path of the in-quadrature signal to generate another in-phase component with much lower harmonic content. The proposed method imposes only a small computational burden on the existing SOGI-PLL compared to the previously presented methods that address the input voltage harmonic problem. Moreover, this method can work properly within the allowable range of grid voltage frequency deviations. The proposed integrator benefits from an error-decaying mechanism to overcome dc drift in pure integrators. The integrator has been designed based on theoretical equations. The validity of the proposed QSG and theoretical equations is evaluated using simulations and experimental studies. A fixed-point representation of the proposed QSG is also provided for implementation on low-cost microcontrollers.Keywords
This publication has 44 references indexed in Scilit:
- Variable-Structure Generalized Delayed Signal Cancellation PLL to Improve Convergence TimeIEEE Transactions on Industrial Electronics, 2015
- A Robust Synchronization to Enhance the Power Quality of Renewable Energy SystemsIEEE Transactions on Industrial Electronics, 2015
- Hybrid Synchronous/Stationary Reference-Frame-Filtering-Based PLLIEEE Transactions on Industrial Electronics, 2015
- A Method to Improve the Dynamic Performance of Moving Average Filter-Based PLLIEEE Transactions on Power Electronics, 2014
- Moving Average Filter Based Phase-Locked Loops: Performance Analysis and Design GuidelinesIEEE Transactions on Power Electronics, 2014
- dq-Frame Cascaded Delayed Signal Cancellation- Based PLL: Analysis, Design, and Comparison With Moving Average Filter-Based PLLIEEE Transactions on Power Electronics, 2014
- Accurate Estimation of Single-Phase Grid Voltage Parameters Under Distorted ConditionsIEEE Transactions on Power Delivery, 2014
- Rotor position estimator for stator flux-oriented sensorless control of slip ring induction machineIET Electric Power Applications, 2009
- An improved stator flux estimation for speed sensorless stator flux orientation control of induction motorsIEEE Transactions on Power Electronics, 2000
- New integration algorithms for estimating motor flux over a wide speed rangeIEEE Transactions on Power Electronics, 1998