Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer
Open Access
- 2 March 2020
- journal article
- research article
- Published by Springer Nature in Eye and Vision
- Vol. 7 (1) , 1-9
Abstract
Background: To evaluate the effect of orthokeratology on precision of measurements in children using a new swept-source optical coherence tomography (SS-OCT) optical biometer (OA-2000), and agreement between its measurements and those provided by the commonly used IOLMaster based on partial coherence interferometry (PCI). Methods: This study recruited fifty-one eyes of 51 normal children (8–16 years). An operator took measurements with the two biometers. Then, a second operator took measurements with the SS-OCT biometer. After orthokeratology was performed for one month, the same operators repeated the same procedures. Axial length (AL), mean keratometry (Km) at 2.5 mm and 3.0 mm diameters (Km2.5 and Km3.0), central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness (LT) and corneal diameter (CD) were analyzed. Results: With the SS-OCT optical biometer, the test-retest repeatability of AL measurements was < 0.06 mm. For all parameters, the coefficients of variation were < 1.23% and the intraclass correlation coefficients were > 0.95. The 95% limits of agreement of difference between the two devices for CD parameter were up to 1.53 mm. After orthokeratology, the fluctuation ranges of difference for Km3.0 measurement was 1.11 times higher than before orthokeratology, while the absolute values of difference for AL, Km2.5, ACD and CD measurements were comparable. Conclusions: Before and after orthokeratology, the SS-OCT biometer showed high repeatability and reproducibility for all measurements. Wearing orthokeratology contact lenses affected the agreement between SS-OCT and PCI biometers for Km3.0 measurements. The CD measurement showed poor agreement between the two devices.Keywords
Funding Information
- Zhejiang Provincial Key Research and Development Program (2018C03012)
- Medical and Health Science and Technology Program of Zhejiang Province (2019KY111)
- Zhejiang Provincial High-level Talents Program (2017-102)
- Foundation of Wenzhou City Science & Technology Bureau (Y20180174)
This publication has 46 references indexed in Scilit:
- Repeatability and interobserver reproducibility of a new optical biometer based on swept-source optical coherence tomography and comparison with IOLMasterBritish Journal of Ophthalmology, 2016
- New Perspective on Myopia Control with OrthokeratologyOptometry and Vision Science, 2016
- Repeatability and reproducibility of ocular biometry using a new noncontact optical low-coherence interferometerJournal of Cataract & Refractive Surgery, 2015
- Repeatability and reproducibility of a new optical biometer in normal and keratoconic eyesJournal of Cataract & Refractive Surgery, 2015
- Human Participants in Engineering Research: Notes from a Fledgling Ethics CommitteeScience and Engineering Ethics, 2014
- Dual versus single Scheimpflug camera for anterior segment analysis: Precision and agreementJournal of Cataract & Refractive Surgery, 2012
- Precision of biometry, keratometry, and refractive measurements with a partial coherence interferometry–keratometry deviceJournal of Cataract & Refractive Surgery, 2010
- Orthokeratology review and updateClinical and Experimental Optometry, 2006
- Highly Precise Eye Length Measurements in Children Aged 3 Through 12 YearsArchives of Ophthalmology (1950), 2003
- A new non-contact optical device for ocular biometryBritish Journal of Ophthalmology, 2002