X-Ray Radiography Study of the Interior Ballistics of a Model Solid Rocket Motor
- 1 April 2025
- journal article
- research article
- Published by Pleiades Publishing Ltd in Combustion, Explosion, and Shock Waves
- Vol. 61 (2) , 200-205
Abstract
A contactless X-ray radiography technique for diagnostics of solid rocket motors (SRMs) is presented. An experimental study was performed to visualize intrachamber processes and determine the solid propellant burning rate in a model E-5-0 SRM using an X-ray system consisting of an X-ray source and a dynamic X-ray detector which are located at a given distance from the test object. The possibility of contactless determination of the propellant burning rate based on an analysis of gray level changes near the burning surface was confirmed experimentally. Radiography results are in satisfactory agreement with the results of other methods for determining the solid propellant burning rate.Keywords
This publication has 3 references indexed in Scilit:
- Non-Contact Acoustic Method for Determining the Pressure in the Combustion Chamber of a Model Solid Rocket MotorCombustion, Explosion, and Shock Waves, 2023
- Study of Intra-Chamber Processes in Solid Rocket Motors by Fiber Optic SensorsSensors, 2021
- Methods and means of narrow-angle tomography diagnostics of flow parameters of ion and plasma rocket engines for spacecraftComputer Optics, 2016