Effect of Off-Axis Fluoroscopy Imaging on Two-Dimensional Kinematics in the Lumbar Spine: A Dynamic In Vitro Validation Study
Authors:
- 31 March 2016
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 138 (5) , 054502-0545026
Abstract
Spine intersegmental motion parameters and the resultant regional patterns may be useful for biomechanical classification of low back pain (LBP) as well as assessing the appropriate intervention strategy. Because of its availability and reasonable cost, two-dimensional (2D) fluoroscopy has great potential as a diagnostic and evaluative tool. However, the technique of quantifying intervertebral motion in the lumbar spine must be validated, and the sensitivity assessed. The purpose of this investigation was to (1) compare synchronous fluoroscopic and optoelectronic measures of intervertebral rotations during dynamic flexion–extension movements in vitro and (2) assess the effect of C-arm rotation to simulate off-axis patient alignment on intervertebral kinematics measures. Six cadaveric lumbar–sacrum specimens were dissected, and active marker optoelectronic sensors were rigidly attached to the bodies of L2–S1. Fluoroscopic sequences and optoelectronic kinematic data (0.15-mm linear, 0.17–0.20 deg rotational, accuracy) were obtained simultaneously. After images were obtained in a true sagittal plane, the image receptor was rotated in 5 deg increments (posterior oblique angulations) from 5 deg to 15 deg. Quantitative motion analysis (qma) software was used to determine the intersegmental rotations from the fluoroscopic images. The mean absolute rotation differences between optoelectronic values and dynamic fluoroscopic values were less than 0.5 deg for all the motion segments at each off-axis fluoroscopic rotation and were not significantly different (P > 0.05) for any of the off-axis rotations of the fluoroscope. Small misalignments of the lumbar spine relative to the fluoroscope did not introduce measurement variation in relative segmental rotations greater than that observed when the spine and fluoroscope were perpendicular to each other, suggesting that fluoroscopic measures of relative segmental rotation during flexion–extension are likely robust, even when patient alignment is not perfect.Keywords
This publication has 27 references indexed in Scilit:
- Static and Dynamic Error of a Biplanar Videoradiography System Using Marker-Based and Markerless Tracking TechniquesJournal of Biomechanical Engineering, 2011
- A dynamic method for in vitro multisegment spine testingOrthopaedics & Traumatology: Surgery & Research, 2010
- In Vivo Kinematics after a Cruciate-substituting TKAClinical Orthopaedics and Related Research, 2010
- Kinematic analysis of dynamic lumbar motion in patients with lumbar segmental instability using digital videofluoroscopyEuropean Spine Journal, 2009
- Quantification of a Meaningful Change in Low Back Functional ImpairmentSpine, 2009
- Movement control tests of the low back; evaluation of the difference between patients with low back pain and healthy controlsBMC Musculoskeletal Disorders, 2008
- Accuracy and precision of a method to study kinematics of the temporomandibular joint: Combination of motion data and CT imagingJournal of Biomechanics, 2008
- Validation of a New Model-Based Tracking Technique for Measuring Three-Dimensional, In Vivo Glenohumeral Joint KinematicsJournal of Biomechanical Engineering, 2006
- Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopyIEEE Transactions on Biomedical Engineering, 1996
- Back Pain and SciaticaNew England Journal of Medicine, 1988