Doses to patients from routine diagnostic X-ray examinations in England

Authors:
  • PSP. C. Shrimpton
    P. C. Shrimpton
  • BWB. F. Wall
    B. F. Wall
  • DJD. G. Jones
    D. G. Jones
  • EFE. S. Fisher
    E. S. Fisher
  • MHM. C. Hillier
    M. C. Hillier
  • GKG. M. Kendall
    G. M. Kendall

Abstract
A collaborative survey between the National Radiological Protection Board and the Hospital Physicists' Association has been conducted to ascertain current levels of exposure for patients undergoing 10 routine types of X-ray examination in England. The main part of this study consisted of measurements on nearly 3200 patients attending 20 randomly selected English hospitals. The energy imparted to each patient was determined from a measurement of the total exposure–area product for the examination. In addition, thermoluminescent dosemeters were attached to the patient's skin to enable the derivation of doses to the major radiosensitive organs, either directly or using appropriate conversion factors calculated for a mathematical phantom by a Monte Carlo technique. Histograms are presented showing the wide distributions often observed in the doses for each type of examination. Mean values of exposure–area product, energy imparted to the patient, entrance skin dose per film and organ dose are reported, togethe...

This publication has 7 references indexed in Scilit: