Comparison of Joint Perception Between Posterior-Stabilized and Ultracongruent Total Knee Arthroplasty in the Same Patient
- 2 December 2020
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (1) , 44-52
Abstract
Background: Posterior-stabilized and ultracongruent designs are 2 common examples of posterior cruciate ligament-substituting total knee arthroplasty (TKA) prostheses. There is a lack of evidence regarding joint perception differences between ultracongruent and posterior-stabilized TKA. The purpose of this study was to compare the postoperative knee stability, function, and joint perception between ultracongruent and posterior-stabilized TKA in the same patients in order to determine whether there was a difference based on design. Methods: This prospective, randomized controlled trial included 50 patients who underwent same-day bilateral TKA utilizing Persona (Zimmer Biomet) posterior-stabilized implants in 1 knee (posterior-stabilized group) and ultracongruent implants in the other knee (ultracongruent group). At 2 years postoperatively, patients were evaluated for knee stability, function, and joint perception. Postoperative static knee anteroposterior stability and femoral rollback were compared. Knee function was evaluated with use of the Knee Society Score and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Joint perception was compared by evaluating noise generation, side preference, satisfaction, and the Forgotten Joint Score. Results: The ultracongruent group had more knee anteroposterior laxity (4.5 mm compared with 1.8 mm in the posterior-stabilized group; p < 0.001) and less femoral rollback (4.2 mm compared with 9.0 mm in the posterior-stabilized group; p < 0.001). Knee Society Score and WOMAC scores were not significantly different between groups (all p > 0.05). Although the ultracongruent group showed less noise generation than the posterior-stabilized group (18% compared with 38%, respectively; p = 0.026), there were no differences in side preference, satisfaction, or Forgotten Joint Score (all p > 0.05). Conclusions: Both groups had similar joint perception 2 years postoperatively, with obvious differences in noise generation and more sagittal laxity with less femoral rollback in the ultracongruent group. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.Keywords
This publication has 34 references indexed in Scilit:
- Joint Awareness in Different Types of Knee Arthroplasty Evaluated With the Forgotten Joint ScoreThe Journal of Arthroplasty, 2014
- Trends in Use of Total Knee Arthroplasty in Korea From 2001 to 2010Clinical Orthopaedics and Related Research, 2013
- The “Forgotten Joint” as the Ultimate Goal in Joint ArthroplastyThe Journal of Arthroplasty, 2012
- Noise, Numbness, and Kneeling Difficulties After Total Knee ArthroplastyThe Journal of Arthroplasty, 2011
- Assessment of tibiofemoral position in total knee arthroplasty using the active flexion lateral radiographThe Knee, 2010
- Patient Satisfaction after Total Knee Arthroplasty: Who is Satisfied and Who is Not?Clinical Orthopaedics and Related Research, 2010
- The role of pain and function in determining patient satisfaction after total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2007
- Femoral rollback of cruciate-retaining and posterior-stabilized total knee replacements: In vivo fluoroscopic analysis during activities of daily livingJournal of Orthopaedic Research, 2006
- In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplastyJournal of Biomechanics, 2005
- The Patellar Clunk SyndromeClinical Orthopaedics and Related Research, 1989