Jin Hwa Jeon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jin Hwa Jeon has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Chul Kyu Kim
Department of Orthopaedic Surgery, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
1 shared publication - Donghun Lee
Department of Orthopedic Surgery, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
1 shared publication - In Jun Koh
Joint Replacement Center, Eunpyeong St. Mary’s Hospital, Seoul 03312, Republic of Korea
1 shared publication - Jaeyoung Lee
Department of Orthopedic Surgery, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
1 shared publication - Kee-Haeng Lee
Department of Orthopedic Surgery, Bucheon St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea
1 shared publication - Keun Young Choi
Department of Orthopaedic Surgery, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul 06591, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 1 January 2021
- Published by The Korean Orthopaedic Association in Journal of the Korean Orthopaedic Association
- Vol. 56 (4) , 305-309
Analysis of the Disposal Rate of Fresh Frozen Femoral Head in the Bone Bank of a Single Hospital
- 1 January 2021
- Published by The Korean Orthopaedic Association in Journal of the Korean Orthopaedic Association
- Vol. 56 (4) , 305-309
Open AccessAnalysis of the Disposal Rate of Fresh Frozen Femoral Head in the Bone Bank of a Single Hospital
- 2 December 2020
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (1) , 44-52
Comparison of Joint Perception Between Posterior-Stabilized and Ultracongruent Total Knee Arthroplasty in the Same Patient
Background: Posterior-stabilized and ultracongruent designs are 2 common examples of posterior cruciate ligament-substituting total knee arthroplasty (TKA) prostheses. There is a lack of evidence regarding joint perception differences between ultracongruent and posterior-stabilized TKA. The purpose of this study was to compare the postoperative knee stability, function, and joint perception between ultracongruent and posterior-stabilized TKA in the same patients in order to determine whether there was a difference based on design. Methods: This prospective, randomized controlled trial included 50 patients who underwent same-day bilateral TKA utilizing Persona (Zimmer Biomet) posterior-stabilized implants in 1 knee (posterior-stabilized group) and ultracongruent implants in the other knee (ultracongruent group). At 2 years postoperatively, patients were evaluated for knee stability, function, and joint perception. Postoperative static knee anteroposterior stability and femoral rollback were compared. Knee function was evaluated with use of the Knee Society Score and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Joint perception was compared by evaluating noise generation, side preference, satisfaction, and the Forgotten Joint Score. Results: The ultracongruent group had more knee anteroposterior laxity (4.5 mm compared with 1.8 mm in the posterior-stabilized group; p < 0.001) and less femoral rollback (4.2 mm compared with 9.0 mm in the posterior-stabilized group; p < 0.001). Knee Society Score and WOMAC scores were not significantly different between groups (all p > 0.05). Although the ultracongruent group showed less noise generation than the posterior-stabilized group (18% compared with 38%, respectively; p = 0.026), there were no differences in side preference, satisfaction, or Forgotten Joint Score (all p > 0.05). Conclusions: Both groups had similar joint perception 2 years postoperatively, with obvious differences in noise generation and more sagittal laxity with less femoral rollback in the ultracongruent group. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
- 2 December 2020
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 103 (1) , 44-52
Comparison of Joint Perception Between Posterior-Stabilized and Ultracongruent Total Knee Arthroplasty in the Same Patient
Background: Posterior-stabilized and ultracongruent designs are 2 common examples of posterior cruciate ligament-substituting total knee arthroplasty (TKA) prostheses. There is a lack of evidence regarding joint perception differences between ultracongruent and posterior-stabilized TKA. The purpose of this study was to compare the postoperative knee stability, function, and joint perception between ultracongruent and posterior-stabilized TKA in the same patients in order to determine whether there was a difference based on design. Methods: This prospective, randomized controlled trial included 50 patients who underwent same-day bilateral TKA utilizing Persona (Zimmer Biomet) posterior-stabilized implants in 1 knee (posterior-stabilized group) and ultracongruent implants in the other knee (ultracongruent group). At 2 years postoperatively, patients were evaluated for knee stability, function, and joint perception. Postoperative static knee anteroposterior stability and femoral rollback were compared. Knee function was evaluated with use of the Knee Society Score and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Joint perception was compared by evaluating noise generation, side preference, satisfaction, and the Forgotten Joint Score. Results: The ultracongruent group had more knee anteroposterior laxity (4.5 mm compared with 1.8 mm in the posterior-stabilized group; p < 0.001) and less femoral rollback (4.2 mm compared with 9.0 mm in the posterior-stabilized group; p < 0.001). Knee Society Score and WOMAC scores were not significantly different between groups (all p > 0.05). Although the ultracongruent group showed less noise generation than the posterior-stabilized group (18% compared with 38%, respectively; p = 0.026), there were no differences in side preference, satisfaction, or Forgotten Joint Score (all p > 0.05). Conclusions: Both groups had similar joint perception 2 years postoperatively, with obvious differences in noise generation and more sagittal laxity with less femoral rollback in the ultracongruent group. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.