Test-retest repeatability of intravoxel incoherent motion (IVIM) measurements in the cervical cord
Open Access
- 10 February 2025
- journal article
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Abstract
Intravoxel incoherent motion (IVIM) measurements allow to probe tissue microcirculation non-invasively. Spinal cord perfusion has been shown to be altered following different neurological pathologies. A non-invasive imaging protocol to assess perfusion in the cervical cord is, therefore, clinically relevant. This work aimed at assessing the reliability of IVIM parameters sensitive to perfusion changes in the cervical cord by determining the test-retest variability across subjects and different post-processing fitting algorithms. IVIM test-retest scans were acquired in the cervical cord (C1-C3) of 10 healthy subjects on a 3T MRI scanner, with a 15-minute break in-between. IVIM parameters, including microvascular volume fraction (F), pseudo-diffusion coefficient (D*), blood flow-related coefficient (F·D*), and diffusion coefficient (D), were derived using voxel-wise and region of interest (ROI)-wise fits. The reliability of each IVIM parameter was determined with coefficients of variation (CV), intraclass correlation coefficients (ICC), Bland-Altman analysis, and linear regression. To assess the effects of the different fitting approaches, a two-way repeated-measures analysis of variance (ANOVA) was conducted on the CVs calculated across fitting algorithms. Mean CVs of IVIM parameters calculated across subjects using the voxel-wise fit were lower in the white matter (WM) and grey matter (GM): (WM: 2.6% to 15.6%; GM: 2.2% to 16.4%) compared with those calculated using the ROI-wise fit approach (WM: 4.5% to 32.2%; GM: 3.4% to 53.4%). The voxel-wise fit in the WM yielded higher ICC values (good-to-excellent, 0.71–0.97) compared to the ROI-wise fit approach (poor-to-excellent, 0.49–0.90). IVIM parameters, derived using the voxel-wise fitting approach, demonstrated a high reliability in the cervical cord. Results highlight the high variability of IVIM parameter values depending on the fitting approach, underlining the importance of characterizing the reliability of IVIM acquisition and fitting configuration in the relevant organ of interest. Robust IVIM metrics using a voxel-wise one-step approach, observed across scans and subjects, can facilitate studies targeting perfusion impairment and pave the way to future clinical trials assessing perfusion impairment as a potential quantitative biomarker.Keywords
All Related Versions
Funding Information
- Wings for Life charity (WFL-CH-19/20)
- Balgrist Stiftung
- International Foundation for Research in Paraplegia (IRP-158)
- Wilhelm Hurka Foundation UZH
- SNSF (Eccellenza fellowship/181362)
This publication has 61 references indexed in Scilit:
- Short‐Term Repeatability of in Vivo Cardiac Intravoxel Incoherent Motion Tensor Imaging in Healthy Human VolunteersJournal of Magnetic Resonance Imaging, 2021
- Lung Cancer: Short-Term Reproducibility of Intravoxel Incoherent Motion Parameters and Apparent Diffusion Coefficient at 3TJournal of Magnetic Resonance Imaging, 2018
- Intravoxel incoherent motion diffusion‐weighted MRI of the abdomen: The effect of fitting algorithms on the accuracy and reliability of the parametersJournal of Magnetic Resonance Imaging, 2016
- Evaluation of intravoxel incoherent motion fitting methods in low‐perfused tissueJournal of Magnetic Resonance Imaging, 2016
- Spinal cord blood flow measurement by arterial spin labelingMagnetic Resonance in Medicine, 2008
- Effects of cord motion on diffusion imaging of the spinal cordMagnetic Resonance in Medicine, 2006
- Practical approaches to the evaluation of signal‐to‐noise ratio performance with parallel imaging: Application with cardiac imaging and a 32‐channel cardiac coilMagnetic Resonance in Medicine, 2005
- In vivo study of microcirculation in canine myocardium using the IVIM method†Magnetic Resonance in Medicine, 2003
- The capillary network: a link between ivim and classical perfusionMagnetic Resonance in Medicine, 1992
- On the precision of diffusion/perfusion imaging by gradient sensitizationMagnetic Resonance in Medicine, 1992