Simon Lévy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Simon Lévy has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
- Virginie Callot
Aix Marseille Univ, CNRS, CRMBM Marseille France
7 shared publications - Julien Cohen-Adad
NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, Canada
4 shared publications - Nikola Stikov
NeuroPoly Polytechnique Montreal Quebec Canada
3 shared publications - Armin Michael Nagel
Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-University Erlangen-Nürnberg, Germany (A.M.N.).
2 shared publications - Bahman Tahayori
University of Melbourne Melbourne Victoria Australia
2 shared publications David Grodzki
MR Application Predevelopment Siemens Healthcare Erlangen Germany
2 shared publications
Latest Publications
- Open Access
- 4 June 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (5) , 1878-1888
In vivo evaluation of population‐specific inversion pulses in parallel transmission
Purpose: The aim of the study was to conduct in vivo evaluation of population‐specific pulses in the context of the MP2RAGE sequence for brain imaging at 7T.Methods: Five clusters were identified in a cohort of 39 volunteers. One cluster centered around the average head shape and position, whereas four others were located toward the extremes of the population distribution. Additionally, the one‐size‐fits‐all solution was considered, using a standard universal pulse (UP) approach. Head shapes were characterized using lateral head breadth (HB), anterior–posterior head length (HL), and Y‐shift metrics. For each group, a 5kT‐points universal inversion pulse was computed and evaluated on four new test anatomies. A Python pipeline was integrated into the image reconstruction routine, using localizer scans to classify head shapes and positions. The pipeline selected one of five precomputed population‐specific pulses or defaulted to the generic UP without extending scan time.Results: The pipeline accurately classified head shapes and selected suitable pulses, enhancing the contrast of MP2RAGE images. Population‐specific pulses helped mitigate some of the performance loss associated with using a one‐size‐fits‐all UP, bringing performance closer to that of fully tailored solutions. This approach was particularly beneficial for individuals with smaller head sizes. However, the performance was worse in larger, more challenging head shapes.Conclusion: The novel head clustering and pulse selection pipeline facilitates the implementation of population‐specific pulses in clinical practice by allowing pulse selection tailored to each head shape and position without increasing scan time.
- 4 June 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (5) , 1878-1888
Open AccessIn vivo evaluation of population‐specific inversion pulses in parallel transmission
Purpose: The aim of the study was to conduct in vivo evaluation of population‐specific pulses in the context of the MP2RAGE sequence for brain imaging at 7T.Methods: Five clusters were identified in a cohort of 39 volunteers. One cluster centered around the average head shape and position, whereas four others were located toward the extremes of the population distribution. Additionally, the one‐size‐fits‐all solution was considered, using a standard universal pulse (UP) approach. Head shapes were characterized using lateral head breadth (HB), anterior–posterior head length (HL), and Y‐shift metrics. For each group, a 5kT‐points universal inversion pulse was computed and evaluated on four new test anatomies. A Python pipeline was integrated into the image reconstruction routine, using localizer scans to classify head shapes and positions. The pipeline selected one of five precomputed population‐specific pulses or defaulted to the generic UP without extending scan time.Results: The pipeline accurately classified head shapes and selected suitable pulses, enhancing the contrast of MP2RAGE images. Population‐specific pulses helped mitigate some of the performance loss associated with using a one‐size‐fits‐all UP, bringing performance closer to that of fully tailored solutions. This approach was particularly beneficial for individuals with smaller head sizes. However, the performance was worse in larger, more challenging head shapes.Conclusion: The novel head clustering and pulse selection pipeline facilitates the implementation of population‐specific pulses in clinical practice by allowing pulse selection tailored to each head shape and position without increasing scan time.
- Open Access
- 17 February 2025
- Published by SAGE Publications in Journal of Neurotrauma
- Vol. 42 (3-4) , 280-291
Spinal Cord Blood Perfusion Deficit is Associated with Clinical Impairment after Spinal Cord Injury
Spinal cord injury (SCI) results in intramedullary microvasculature disruption and blood perfusion deficit at and remote from the injury site. However, the relationship between remote vascular impairment and functional recovery remains understudied. We characterized perfusion impairment in vivo , rostral to the injury, using magnetic resonance imaging (MRI), and investigated its association with lesion extent and impairment following SCI. Twenty-one patients with chronic cervical SCI and 39 healthy controls (HC) underwent a high-resolution MRI protocol, including intravoxel incoherent motion (IVIM) and T2*-weighted MRI covering C1–C3 cervical levels, as well as T2-weighted MRI to determine lesion volumes. IVIM matrices (i.e., blood volume fraction, velocity, flow indices, and diffusion) and cord structural characteristics were calculated to assess perfusion changes and cervical cord atrophy, respectively. Patients with SCI additionally underwent a standard clinical examination protocol to assess functional impairment. Correlation analysis was used to investigate associations between IVIM parameters with lesion volume and sensorimotor dysfunction. Cervical cord white and gray matter were atrophied (27.60% and 21.10%, p < 0.0001, respectively) above the cervical cord injury, accompanied by a lower blood volume fraction (−22.05%, p < 0.001) and a higher blood velocity-related index (+38.72%, p < 0.0001) in patients with SCI compared with HC. Crucially, gray matter remote perfusion deficit correlated with larger lesion volumes and clinical impairment. This study shows clinically eloquent perfusion deficit rostral to a SCI, its magnitude driven by injury severity. These findings indicate trauma-induced widespread microvascular alterations beyond the injury site. Perfusion MRI matrices in the spinal cord hold promise as biomarkers for monitoring treatment effects and dynamic changes in microvasculature integrity following SCI.
- 17 February 2025
- Published by SAGE Publications in Journal of Neurotrauma
- Vol. 42 (3-4) , 280-291
Open AccessSpinal Cord Blood Perfusion Deficit is Associated with Clinical Impairment after Spinal Cord Injury
Spinal cord injury (SCI) results in intramedullary microvasculature disruption and blood perfusion deficit at and remote from the injury site. However, the relationship between remote vascular impairment and functional recovery remains understudied. We characterized perfusion impairment in vivo , rostral to the injury, using magnetic resonance imaging (MRI), and investigated its association with lesion extent and impairment following SCI. Twenty-one patients with chronic cervical SCI and 39 healthy controls (HC) underwent a high-resolution MRI protocol, including intravoxel incoherent motion (IVIM) and T2*-weighted MRI covering C1–C3 cervical levels, as well as T2-weighted MRI to determine lesion volumes. IVIM matrices (i.e., blood volume fraction, velocity, flow indices, and diffusion) and cord structural characteristics were calculated to assess perfusion changes and cervical cord atrophy, respectively. Patients with SCI additionally underwent a standard clinical examination protocol to assess functional impairment. Correlation analysis was used to investigate associations between IVIM parameters with lesion volume and sensorimotor dysfunction. Cervical cord white and gray matter were atrophied (27.60% and 21.10%, p < 0.0001, respectively) above the cervical cord injury, accompanied by a lower blood volume fraction (−22.05%, p < 0.001) and a higher blood velocity-related index (+38.72%, p < 0.0001) in patients with SCI compared with HC. Crucially, gray matter remote perfusion deficit correlated with larger lesion volumes and clinical impairment. This study shows clinically eloquent perfusion deficit rostral to a SCI, its magnitude driven by injury severity. These findings indicate trauma-induced widespread microvascular alterations beyond the injury site. Perfusion MRI matrices in the spinal cord hold promise as biomarkers for monitoring treatment effects and dynamic changes in microvasculature integrity following SCI.
- Open Access
- 10 February 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Test-retest repeatability of intravoxel incoherent motion (IVIM) measurements in the cervical cord
Intravoxel incoherent motion (IVIM) measurements allow to probe tissue microcirculation non-invasively. Spinal cord perfusion has been shown to be altered following different neurological pathologies. A non-invasive imaging protocol to assess perfusion in the cervical cord is, therefore, clinically relevant. This work aimed at assessing the reliability of IVIM parameters sensitive to perfusion changes in the cervical cord by determining the test-retest variability across subjects and different post-processing fitting algorithms. IVIM test-retest scans were acquired in the cervical cord (C1-C3) of 10 healthy subjects on a 3T MRI scanner, with a 15-minute break in-between. IVIM parameters, including microvascular volume fraction (F), pseudo-diffusion coefficient (D*), blood flow-related coefficient (F·D*), and diffusion coefficient (D), were derived using voxel-wise and region of interest (ROI)-wise fits. The reliability of each IVIM parameter was determined with coefficients of variation (CV), intraclass correlation coefficients (ICC), Bland-Altman analysis, and linear regression. To assess the effects of the different fitting approaches, a two-way repeated-measures analysis of variance (ANOVA) was conducted on the CVs calculated across fitting algorithms. Mean CVs of IVIM parameters calculated across subjects using the voxel-wise fit were lower in the white matter (WM) and grey matter (GM): (WM: 2.6% to 15.6%; GM: 2.2% to 16.4%) compared with those calculated using the ROI-wise fit approach (WM: 4.5% to 32.2%; GM: 3.4% to 53.4%). The voxel-wise fit in the WM yielded higher ICC values (good-to-excellent, 0.71–0.97) compared to the ROI-wise fit approach (poor-to-excellent, 0.49–0.90). IVIM parameters, derived using the voxel-wise fitting approach, demonstrated a high reliability in the cervical cord. Results highlight the high variability of IVIM parameter values depending on the fitting approach, underlining the importance of characterizing the reliability of IVIM acquisition and fitting configuration in the relevant organ of interest. Robust IVIM metrics using a voxel-wise one-step approach, observed across scans and subjects, can facilitate studies targeting perfusion impairment and pave the way to future clinical trials assessing perfusion impairment as a potential quantitative biomarker.
- 10 February 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Open AccessTest-retest repeatability of intravoxel incoherent motion (IVIM) measurements in the cervical cord
Intravoxel incoherent motion (IVIM) measurements allow to probe tissue microcirculation non-invasively. Spinal cord perfusion has been shown to be altered following different neurological pathologies. A non-invasive imaging protocol to assess perfusion in the cervical cord is, therefore, clinically relevant. This work aimed at assessing the reliability of IVIM parameters sensitive to perfusion changes in the cervical cord by determining the test-retest variability across subjects and different post-processing fitting algorithms. IVIM test-retest scans were acquired in the cervical cord (C1-C3) of 10 healthy subjects on a 3T MRI scanner, with a 15-minute break in-between. IVIM parameters, including microvascular volume fraction (F), pseudo-diffusion coefficient (D*), blood flow-related coefficient (F·D*), and diffusion coefficient (D), were derived using voxel-wise and region of interest (ROI)-wise fits. The reliability of each IVIM parameter was determined with coefficients of variation (CV), intraclass correlation coefficients (ICC), Bland-Altman analysis, and linear regression. To assess the effects of the different fitting approaches, a two-way repeated-measures analysis of variance (ANOVA) was conducted on the CVs calculated across fitting algorithms. Mean CVs of IVIM parameters calculated across subjects using the voxel-wise fit were lower in the white matter (WM) and grey matter (GM): (WM: 2.6% to 15.6%; GM: 2.2% to 16.4%) compared with those calculated using the ROI-wise fit approach (WM: 4.5% to 32.2%; GM: 3.4% to 53.4%). The voxel-wise fit in the WM yielded higher ICC values (good-to-excellent, 0.71–0.97) compared to the ROI-wise fit approach (poor-to-excellent, 0.49–0.90). IVIM parameters, derived using the voxel-wise fitting approach, demonstrated a high reliability in the cervical cord. Results highlight the high variability of IVIM parameter values depending on the fitting approach, underlining the importance of characterizing the reliability of IVIM acquisition and fitting configuration in the relevant organ of interest. Robust IVIM metrics using a voxel-wise one-step approach, observed across scans and subjects, can facilitate studies targeting perfusion impairment and pave the way to future clinical trials assessing perfusion impairment as a potential quantitative biomarker.
- Open Access
- 17 October 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (2) , 570-582
What can we gain from subpopulation universal pulses? A simulation‐based study
Purpose: The aim of the study was to explore a novel methodology for designing universal pulses (UPs) that balances the benefits of a calibration‐free approach with subject‐specific online pulse design.Methods: The proposed method involves segmenting the population into subpopulations with variability in anatomical shapes and positions reduced to 75%, 50%, and 25% of their original values while keeping the mean values unchanged. An additional 25% extreme case with a large volume of interest and shifted position was included. For each group, a 5kT‐points universal inversion pulse was designed and assessed by the normalized root mean square error (NRMSE) on the target longitudinal magnetization profile. The performance was compared to the conventional one‐size‐fits‐all approach. A total of 132 electromagnetic simulations were executed to generate representative anatomies and specific absorption rate (SAR) distributions in a three‐dimensional parameter space comprised of head breadth, head length, and Y‐shift. The 99.9th percentile on the peak local SAR distribution was utilized to establish an intersubject variability safety margin.Results: UPs designed for subpopulations with decreased head shape and position variability reduced the anatomical safety margin by up to 20%. Furthermore, when a head was significantly different to the average case, the proposed approach improved the inversion homogeneity by up to 24%, compared to the conventional one‐size‐fits‐all approach.Conclusion: Subpopulation UPs present an opportunity to improve the homogeneity and reduce anatomical SAR safety margins at 7T without additional acquisition time for calibration.
- 17 October 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (2) , 570-582
Open AccessWhat can we gain from subpopulation universal pulses? A simulation‐based study
Purpose: The aim of the study was to explore a novel methodology for designing universal pulses (UPs) that balances the benefits of a calibration‐free approach with subject‐specific online pulse design.Methods: The proposed method involves segmenting the population into subpopulations with variability in anatomical shapes and positions reduced to 75%, 50%, and 25% of their original values while keeping the mean values unchanged. An additional 25% extreme case with a large volume of interest and shifted position was included. For each group, a 5kT‐points universal inversion pulse was designed and assessed by the normalized root mean square error (NRMSE) on the target longitudinal magnetization profile. The performance was compared to the conventional one‐size‐fits‐all approach. A total of 132 electromagnetic simulations were executed to generate representative anatomies and specific absorption rate (SAR) distributions in a three‐dimensional parameter space comprised of head breadth, head length, and Y‐shift. The 99.9th percentile on the peak local SAR distribution was utilized to establish an intersubject variability safety margin.Results: UPs designed for subpopulations with decreased head shape and position variability reduced the anatomical safety margin by up to 20%. Furthermore, when a head was significantly different to the average case, the proposed approach improved the inversion homogeneity by up to 24%, compared to the conventional one‐size‐fits‐all approach.Conclusion: Subpopulation UPs present an opportunity to improve the homogeneity and reduce anatomical SAR safety margins at 7T without additional acquisition time for calibration.
- Open Access
- 21 September 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (1) , 77-94
Clinically compatible subject‐specific dynamic parallel transmit pulse design for homogeneous fat saturation and water‐excitation at 7T: Proof‐of‐concept for CEST MRI of the brain
Purpose To evaluate the benefits and challenges of dynamic parallel transmit (pTx) pulses for fat saturation (FS) and water-excitation (WE), in the context of CEST MRI. Methods "Universal" k(T)-points (for FS) and spiral non-selective (for WE) trajectories were optimized offline for flip angle (FA) homogeneity. Routines to optimize the pulse shape online, based on the subject's fields maps, were implemented (target FA of 110 degrees/0 degrees for FS, 0 degrees/5 degrees for WE at fat/water frequencies). The pulses were inserted in a CEST sequence with a pTx readout. The different fat suppression schemes and their effects on CEST contrasts were compared in 12 volunteers at 7T. Results With a 25%-shorter pulse duration, pTx FS largely improved the FA homogeneity (root-mean-square-error (RMSE) = 12.3 degrees vs. 53.4 degrees with circularly-polarized mode, at the fat frequency). However, the spectral selectivity was degraded mainly in the cerebellum and close to the sinuses (RMSE = 5.8 degrees vs. 0.2 degrees at the water frequency). Similarly, pTx WE showed a trade-off between FA homogeneity and spectral selectivity compared to pTx non-selective pulses (RMSE = 0.9 degrees and 1.1 degrees at the fat and water frequencies, vs. 4.6 degrees and 0.5 degrees). In the brain, CEST metrics were reduced by up to 31.9% at -3.3 ppm with pTx FS, suggesting a mitigated lipid-induced bias. Conclusion This clinically compatible implementation of dynamic pTx pulses improved the fat suppression homogeneity at 7T taking into account the subject-specific B-0 heterogeneities online. This study highlights the lipid-induced biases on the CEST z-spectrum. The results are promising for body applications where B-0 heterogeneities and fat are more substantial.
- 21 September 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (1) , 77-94
Open AccessClinically compatible subject‐specific dynamic parallel transmit pulse design for homogeneous fat saturation and water‐excitation at 7T: Proof‐of‐concept for CEST MRI of the brain
Purpose To evaluate the benefits and challenges of dynamic parallel transmit (pTx) pulses for fat saturation (FS) and water-excitation (WE), in the context of CEST MRI. Methods "Universal" k(T)-points (for FS) and spiral non-selective (for WE) trajectories were optimized offline for flip angle (FA) homogeneity. Routines to optimize the pulse shape online, based on the subject's fields maps, were implemented (target FA of 110 degrees/0 degrees for FS, 0 degrees/5 degrees for WE at fat/water frequencies). The pulses were inserted in a CEST sequence with a pTx readout. The different fat suppression schemes and their effects on CEST contrasts were compared in 12 volunteers at 7T. Results With a 25%-shorter pulse duration, pTx FS largely improved the FA homogeneity (root-mean-square-error (RMSE) = 12.3 degrees vs. 53.4 degrees with circularly-polarized mode, at the fat frequency). However, the spectral selectivity was degraded mainly in the cerebellum and close to the sinuses (RMSE = 5.8 degrees vs. 0.2 degrees at the water frequency). Similarly, pTx WE showed a trade-off between FA homogeneity and spectral selectivity compared to pTx non-selective pulses (RMSE = 0.9 degrees and 1.1 degrees at the fat and water frequencies, vs. 4.6 degrees and 0.5 degrees). In the brain, CEST metrics were reduced by up to 31.9% at -3.3 ppm with pTx FS, suggesting a mitigated lipid-induced bias. Conclusion This clinically compatible implementation of dynamic pTx pulses improved the fat suppression homogeneity at 7T taking into account the subject-specific B-0 heterogeneities online. This study highlights the lipid-induced biases on the CEST z-spectrum. The results are promising for body applications where B-0 heterogeneities and fat are more substantial.
- 20 September 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 306 (3) , e221250
Pulmonary Dysfunction after Pediatric COVID-19
Low-field MRI showed persistent pulmonary dysfunction in both children and adolescents recovered from COVID-19 and with long COVID. Background Long COVID occurs in lower frequency in children and adolescents than in adults. Morphologic and free-breathing phase-resolved functional low-field MRI may identify persistent pulmonary ...
- 20 September 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 306 (3) , e221250
Pulmonary Dysfunction after Pediatric COVID-19
Low-field MRI showed persistent pulmonary dysfunction in both children and adolescents recovered from COVID-19 and with long COVID. Background Long COVID occurs in lower frequency in children and adolescents than in adults. Morphologic and free-breathing phase-resolved functional low-field MRI may identify persistent pulmonary ...
- 27 May 2022
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 57 (11) , 742-751
Free-Breathing Low-Field MRI of the Lungs Detects Functional Alterations Associated With Persistent Symptoms After COVID-19 Infection
Objectives: With the COVID-19 pandemic, repetitive lung examinations have become necessary to follow-up symptoms and associated alterations. Low-field MRI, benefiting from reduced susceptibility effects, is a promising alternative for lung imaging to limit radiations absorbed by patients during CT examinations, which also have limited capability to assess functional alterations. The aim of this investigative study was to explore the functional abnormalities that free-breathing 0.55 T MRI in combination with the phase-resolved functional lung (PREFUL) analysis could identify in patients with persistent symptoms after COVID-19 infection. Materials and Methods: Seventy-four COVID-19 patients and 8 healthy volunteers were prospectively scanned in free-breathing with a balanced steady-state free-precession sequence optimized at 0.55 T, 5 months postinfection on average. Normalized perfusion (Q), fractional ventilation (FV), and flow-volume loop correlation (FVLc) maps were extracted with the PREFUL technique. Q, FV, and FVLc defects as well as defect overlaps between these metrics were quantified. Morphological turbo-spin-echo images were also acquired, and the extent of abnormalities was scored by a board-certified radiologist. To investigate the functional correlates of persistent symptoms, a recursive feature elimination algorithm was applied to find the most informative variables to detect the presence of persistent symptoms with a logistic regression model and a cross-validation strategy. All MRI metrics, sex, age, body mass index, and the presence of preexisting lung conditions were included. Results: The most informative variables to detect persistent symptoms were the percentage of concurrent Q and FVLc defects and of areas free of those defects. A detection accuracy of 71.4% was obtained with these 2 variables when fitting the model on the entire dataset. Although none of the single variables differed between patients with and without persistent symptoms (P > 0.05), the combined score of these 2 variables did (P < 0.02). This score also showed a consistent increase from healthy volunteers (7.7) to patients without persistent symptoms (8.2) and with persistent symptoms (8.6). The morphological abnormality score showed poor correlation with the functional parameters. Conclusions: Functional pulmonary examinations using free-breathing 0.55 T MRI with PREFUL analysis revealed potential quantitative markers of impaired lung function in patients with persistent symptoms after COVID-19 infection, potentially complementing morphologic imaging. Future work is needed to explore the translational relevance and clinical implication of these findings.
- 27 May 2022
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 57 (11) , 742-751
Free-Breathing Low-Field MRI of the Lungs Detects Functional Alterations Associated With Persistent Symptoms After COVID-19 Infection
Objectives: With the COVID-19 pandemic, repetitive lung examinations have become necessary to follow-up symptoms and associated alterations. Low-field MRI, benefiting from reduced susceptibility effects, is a promising alternative for lung imaging to limit radiations absorbed by patients during CT examinations, which also have limited capability to assess functional alterations. The aim of this investigative study was to explore the functional abnormalities that free-breathing 0.55 T MRI in combination with the phase-resolved functional lung (PREFUL) analysis could identify in patients with persistent symptoms after COVID-19 infection. Materials and Methods: Seventy-four COVID-19 patients and 8 healthy volunteers were prospectively scanned in free-breathing with a balanced steady-state free-precession sequence optimized at 0.55 T, 5 months postinfection on average. Normalized perfusion (Q), fractional ventilation (FV), and flow-volume loop correlation (FVLc) maps were extracted with the PREFUL technique. Q, FV, and FVLc defects as well as defect overlaps between these metrics were quantified. Morphological turbo-spin-echo images were also acquired, and the extent of abnormalities was scored by a board-certified radiologist. To investigate the functional correlates of persistent symptoms, a recursive feature elimination algorithm was applied to find the most informative variables to detect the presence of persistent symptoms with a logistic regression model and a cross-validation strategy. All MRI metrics, sex, age, body mass index, and the presence of preexisting lung conditions were included. Results: The most informative variables to detect persistent symptoms were the percentage of concurrent Q and FVLc defects and of areas free of those defects. A detection accuracy of 71.4% was obtained with these 2 variables when fitting the model on the entire dataset. Although none of the single variables differed between patients with and without persistent symptoms (P > 0.05), the combined score of these 2 variables did (P < 0.02). This score also showed a consistent increase from healthy volunteers (7.7) to patients without persistent symptoms (8.2) and with persistent symptoms (8.6). The morphological abnormality score showed poor correlation with the functional parameters. Conclusions: Functional pulmonary examinations using free-breathing 0.55 T MRI with PREFUL analysis revealed potential quantitative markers of impaired lung function in patients with persistent symptoms after COVID-19 infection, potentially complementing morphologic imaging. Future work is needed to explore the translational relevance and clinical implication of these findings.
- 13 May 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 42 (7) , 1348-1357
T1 Mapping for Microstructural Assessment of the Cervical Spinal Cord in the Evaluation of Patients with Degenerative Cervical Myelopathy
BACKGROUND AND PURPOSE: Although current radiologic evaluation of degenerative cervical myelopathy by conventional MR imaging accurately demonstrates spondylosis or degenerative disc disease causing spinal cord dysfunction, conventional MR imaging still fails to provide satisfactory anatomic and clinical correlations. In this context, we assessed the potential value of quantitative cervical spinal cord T1 mapping regarding the evaluation of patients with degenerative cervical myelopathy. MATERIALS AND METHODS: Twenty patients diagnosed with mild and moderate-to-severe degenerative cervical myelopathy and 10 healthy subjects were enrolled in a multiparametric MR imaging protocol. Cervical spinal cord T1 mapping was performed with the MP2RAGE sequence procedure. Retrieved data were processed and analyzed regarding the global spinal cord and white and anterior gray matter on the basis of the clinical severity and the spinal canal stenosis grading. RESULTS: Noncompressed levels in healthy controls demonstrated significantly lower T1 values than noncompressed, mild, moderate, and severe stenotic levels in patients. Concerning the entire spinal cord T1 mapping, patients with moderate-to-severe degenerative cervical myelopathy had higher T1 values compared with healthy controls. Regarding the specific levels, patients with moderate-to-severe degenerative cervical myelopathy demonstrated a T1 value increase at C1, C7, and the level of maximal compression compared with healthy controls. Patients with mild degenerative cervical myelopathy had lower T1 values than those with moderate-to-severe degenerative cervical myelopathy at the level of maximal compression. Analyses of white and anterior gray matter confirmed similar results. Strong negative correlations between individual modified Japanese Orthopaedic Association scores and T1 values were also observed. CONCLUSIONS: In this preliminary study, 3D-MP2RAGE T1 mapping demonstrated increased T1 values in the pathology tissue samples, with diffuse medullary alterations in all patients with degenerative cervical myelopathy, especially relevant at C1 (nonstenotic level) and at the maximal compression level. Encouraging correlations observed with the modified Japanese Orthopaedic Association score make this novel approach a potential quantitative biomarker related to clinical severity in degenerative cervical myelopathy. Nevertheless, patients with mild degenerative cervical myelopathy demonstrated nonsignificant results compared with healthy controls and should now be studied in multicenter studies with larger patient populations.
- 13 May 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 42 (7) , 1348-1357
T1 Mapping for Microstructural Assessment of the Cervical Spinal Cord in the Evaluation of Patients with Degenerative Cervical Myelopathy
BACKGROUND AND PURPOSE: Although current radiologic evaluation of degenerative cervical myelopathy by conventional MR imaging accurately demonstrates spondylosis or degenerative disc disease causing spinal cord dysfunction, conventional MR imaging still fails to provide satisfactory anatomic and clinical correlations. In this context, we assessed the potential value of quantitative cervical spinal cord T1 mapping regarding the evaluation of patients with degenerative cervical myelopathy. MATERIALS AND METHODS: Twenty patients diagnosed with mild and moderate-to-severe degenerative cervical myelopathy and 10 healthy subjects were enrolled in a multiparametric MR imaging protocol. Cervical spinal cord T1 mapping was performed with the MP2RAGE sequence procedure. Retrieved data were processed and analyzed regarding the global spinal cord and white and anterior gray matter on the basis of the clinical severity and the spinal canal stenosis grading. RESULTS: Noncompressed levels in healthy controls demonstrated significantly lower T1 values than noncompressed, mild, moderate, and severe stenotic levels in patients. Concerning the entire spinal cord T1 mapping, patients with moderate-to-severe degenerative cervical myelopathy had higher T1 values compared with healthy controls. Regarding the specific levels, patients with moderate-to-severe degenerative cervical myelopathy demonstrated a T1 value increase at C1, C7, and the level of maximal compression compared with healthy controls. Patients with mild degenerative cervical myelopathy had lower T1 values than those with moderate-to-severe degenerative cervical myelopathy at the level of maximal compression. Analyses of white and anterior gray matter confirmed similar results. Strong negative correlations between individual modified Japanese Orthopaedic Association scores and T1 values were also observed. CONCLUSIONS: In this preliminary study, 3D-MP2RAGE T1 mapping demonstrated increased T1 values in the pathology tissue samples, with diffuse medullary alterations in all patients with degenerative cervical myelopathy, especially relevant at C1 (nonstenotic level) and at the maximal compression level. Encouraging correlations observed with the modified Japanese Orthopaedic Association score make this novel approach a potential quantitative biomarker related to clinical severity in degenerative cervical myelopathy. Nevertheless, patients with mild degenerative cervical myelopathy demonstrated nonsignificant results compared with healthy controls and should now be studied in multicenter studies with larger patient populations.
- 5 November 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (3) , 1183-1194
Feasibility of human spinal cord perfusion mapping using dynamic susceptibility contrast imaging at 7T: Preliminary results and identified guidelines
Purpose: To explore the feasibility of dynamic susceptibility contrast MRI at 7 Tesla for human spinal cord perfusion mapping and fill the gap between brain and spinal cord perfusion mapping techniques.Methods: Acquisition protocols for high‐resolution single shot EPI in the spinal cord were optimized for both spin‐echo and gradient‐echo preparations, including cardiac gating, acquisition times and breathing cycle recording. Breathing‐induced MRI signal fluctuations were investigated in healthy volunteers. A specific image‐ and signal‐processing pipeline was implemented to address them. Dynamic susceptibility contrast was then evaluated in 3 healthy volunteers and 5 patients. Bolus depiction on slice‐wise signal within cord was investigated, and maps of relative perfusion indices were computed.Results: Signal fluctuations were increased by 1.9 and 2.3 in free‐breathing compared to apnea with spin‐echo and gradient‐echo, respectively. The ratio between signal fluctuations and bolus peak in healthy volunteers was 5.0% for spin‐echo and 3.8% for gradient‐echo, allowing clear depiction of the bolus on every slice and yielding relative blood flow and volume maps exhibiting the expected higher perfusion of gray matter. However, signal fluctuations in patients were increased by 4 in average (using spin‐echo), compromising the depiction of the bolus in slice‐wise signal. Moreover, 3 of 18 slices had to be discarded because of fat‐aliasing artifacts.Conclusion: Dynamic susceptibility contrast MRI at 7 Tesla showed great potential for spinal cord perfusion mapping with a reliability never achieved thus far for single subject and single slice measurements. Signal stability needs to be improved in acquisition conditions associated with patients; guidelines to achieve that have been identified and shared.
- 5 November 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 85 (3) , 1183-1194
Feasibility of human spinal cord perfusion mapping using dynamic susceptibility contrast imaging at 7T: Preliminary results and identified guidelines
Purpose: To explore the feasibility of dynamic susceptibility contrast MRI at 7 Tesla for human spinal cord perfusion mapping and fill the gap between brain and spinal cord perfusion mapping techniques.Methods: Acquisition protocols for high‐resolution single shot EPI in the spinal cord were optimized for both spin‐echo and gradient‐echo preparations, including cardiac gating, acquisition times and breathing cycle recording. Breathing‐induced MRI signal fluctuations were investigated in healthy volunteers. A specific image‐ and signal‐processing pipeline was implemented to address them. Dynamic susceptibility contrast was then evaluated in 3 healthy volunteers and 5 patients. Bolus depiction on slice‐wise signal within cord was investigated, and maps of relative perfusion indices were computed.Results: Signal fluctuations were increased by 1.9 and 2.3 in free‐breathing compared to apnea with spin‐echo and gradient‐echo, respectively. The ratio between signal fluctuations and bolus peak in healthy volunteers was 5.0% for spin‐echo and 3.8% for gradient‐echo, allowing clear depiction of the bolus on every slice and yielding relative blood flow and volume maps exhibiting the expected higher perfusion of gray matter. However, signal fluctuations in patients were increased by 4 in average (using spin‐echo), compromising the depiction of the bolus in slice‐wise signal. Moreover, 3 of 18 slices had to be discarded because of fat‐aliasing artifacts.Conclusion: Dynamic susceptibility contrast MRI at 7 Tesla showed great potential for spinal cord perfusion mapping with a reliability never achieved thus far for single subject and single slice measurements. Signal stability needs to be improved in acquisition conditions associated with patients; guidelines to achieve that have been identified and shared.
- 14 February 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (3) , 1198-1217
Intravoxel Incoherent Motion at 7 Tesla to quantify human spinal cord perfusion: limitations and promises
Purpose: To develop a noninvasive technique to map human spinal cord (SC) perfusion in vivo. More specifically, to implement an intravoxel incoherent motion (IVIM) protocol at ultrahigh field for the human SC and assess parameters estimation errors.Methods: Monte‐Carlo simulations were conducted to assess estimation errors of 2 standard IVIM fitting approaches (two‐step versus one‐step fit) over the range of IVIM values reported for the human brain and for typical SC diffusivities. Required signal‐to‐noise ratio (SNR) was inferred for estimation of the parameters product, fIVIMD* (microvascular fraction times pseudo‐diffusion coefficient), within 10% error margins. In‐vivo IVIM imaging of the SC was performed at 7T in 6 volunteers. An image processing pipeline is proposed to generate IVIM maps and register them for an atlas‐based region‐wise analysis.Results: Required b = 0 SNRs for 10% error estimation on fIVIMD* with the one‐step fit were 159 and 185 for diffusion‐encoding perpendicular and parallel to the SC axis, respectively. Average in vivo b = 0 SNR within cord was 141 ± 79, corresponding to estimation errors of 12.7% and 14.7% according to numerical simulations. Slice‐ and group‐averaging reduced noise in IVIM maps, highlighting the difference in perfusion between gray and white matter. Mean ± standard deviation fIVIM and D* values across subjects within gray (respectively white) matter were 16.0 ± 1.7 (15.0 ± 1.6)% and 11.4 ± 2.9 (11.5 ± 2.4) × 10−3 mm2/s.Conclusion: Single‐subject data SNR at 7T was insufficient for reliable perfusion estimation. However, atlas‐averaged IVIM maps highlighted the higher microvascular fraction of gray matter compared to white matter, providing first results of healthy human SC perfusion mapping with MRI.
- 14 February 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (3) , 1198-1217
Intravoxel Incoherent Motion at 7 Tesla to quantify human spinal cord perfusion: limitations and promises
Purpose: To develop a noninvasive technique to map human spinal cord (SC) perfusion in vivo. More specifically, to implement an intravoxel incoherent motion (IVIM) protocol at ultrahigh field for the human SC and assess parameters estimation errors.Methods: Monte‐Carlo simulations were conducted to assess estimation errors of 2 standard IVIM fitting approaches (two‐step versus one‐step fit) over the range of IVIM values reported for the human brain and for typical SC diffusivities. Required signal‐to‐noise ratio (SNR) was inferred for estimation of the parameters product, fIVIMD* (microvascular fraction times pseudo‐diffusion coefficient), within 10% error margins. In‐vivo IVIM imaging of the SC was performed at 7T in 6 volunteers. An image processing pipeline is proposed to generate IVIM maps and register them for an atlas‐based region‐wise analysis.Results: Required b = 0 SNRs for 10% error estimation on fIVIMD* with the one‐step fit were 159 and 185 for diffusion‐encoding perpendicular and parallel to the SC axis, respectively. Average in vivo b = 0 SNR within cord was 141 ± 79, corresponding to estimation errors of 12.7% and 14.7% according to numerical simulations. Slice‐ and group‐averaging reduced noise in IVIM maps, highlighting the difference in perfusion between gray and white matter. Mean ± standard deviation fIVIM and D* values across subjects within gray (respectively white) matter were 16.0 ± 1.7 (15.0 ± 1.6)% and 11.4 ± 2.9 (11.5 ± 2.4) × 10−3 mm2/s.Conclusion: Single‐subject data SNR at 7T was insufficient for reliable perfusion estimation. However, atlas‐averaged IVIM maps highlighted the higher microvascular fraction of gray matter compared to white matter, providing first results of healthy human SC perfusion mapping with MRI.