An Energy Efficient Multi-User Asynchronous Wireless Transmitter for Biomedical Signal Acquisition
- 20 May 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 13 (4) , 619-630
Abstract
The paper presents a novel transmitter architecture for short-range asynchronous wireless communication, applicable to simultaneous multi-user wireless acquisition of biological signals. The analog signal, provided from an analog biosensor, is transformed to time information using an Integral Pulse Frequency Modulator (IPFM) as a Time-Encoding Machine (TEM). The IPFM generates a time-encoded unipolar pulse train, maintaining the linear dependence of the output pulse distance on analog input voltage. The system enables continuous acquisition of the signals from multiple sensors in which each transmitter has unique feedback loop delay used for multiuser coding. IPFM pulses trigger the Impulse Radio Ultra-Wideband (IR-UWB) pulse generator directly, providing two Ultra-Wideband (UWB) pulses per each IPFM pulse. Due to the lack of internal clock signal and microprocessor-free multiuser coding, the circuitry satisfies the requirements of multi-user coding energy efficiency and size reduction, which are crucial demands in biomedical applications. The proposed Time-Encoded UWB (TE-UWB) transmitter is implemented in 0.18 μm CMOS technology. Measurement results of the IPFM transfer function for input voltage ranging from 0.15 V to 1.5 V are presented, providing the dependence of the IPFM pulse time distance on analog input voltage and power consumption dependence on the input voltage level. For continuous monitoring operation total power consumption of the transmitter circuitry for the maximum input voltage is 10.8 μW, while for the lowest input voltage it increases to 40.48 μW. The circuit occupies 0.14 mm $^2$ .
Keywords
Funding Information
- Hrvatska Zaklada za Znanost (UIP-2014-09-6219)
- Energy efficient asynchronous wireless transmission
- Europractice MPW
This publication has 34 references indexed in Scilit:
- Performance Assessment of IR-UWB Body Area Network (BAN) Based on IEEE 802.15.6 StandardIEEE Antennas and Wireless Propagation Letters, 2016
- Wearable ECG Based on Impulse-Radio-Type Human Body CommunicationIEEE Transactions on Biomedical Engineering, 2015
- A UWB-Based Sensor-to-Time Transmitter for RF-Powered Sensing ApplicationsIEEE Transactions on Circuits and Systems II: Express Briefs, 2015
- Passive UWB RFID for Tag Localization: Architectures and DesignIEEE Sensors Journal, 2015
- A Single-Chip Full-Duplex High Speed Transceiver for Multi-Site Stimulating and Recording Neural ImplantsIEEE Transactions on Biomedical Circuits and Systems, 2015
- On Integration and Validation of a Very Low Complexity ATC UWB System for Muscle Force TransmissionIEEE Transactions on Biomedical Circuits and Systems, 2015
- From Wearable Sensors to Smart Implants-–Toward Pervasive and Personalized HealthcareIEEE Transactions on Biomedical Engineering, 2015
- Nanostructured CMOS Wireless Ultra-Wideband Label-Free PCR-Free DNA Analysis SoCIEEE Journal of Solid-State Circuits, 2014
- A 9-bit, 14 μW and 0.06 mm$^{2}$ Pulse Position Modulation ADC in 90 nm Digital CMOSIEEE Journal of Solid-State Circuits, 2010
- Analysis and Design of High-Performance Asynchronous Sigma-Delta Modulators With a Binary QuantizerIEEE Journal of Solid-State Circuits, 2006