A Fourier approach to pulse pile‐up in photon‐counting x‐ray detectors
Authors:
- 17 February 2016
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 43 (3) , 1295-1298
Abstract
Purpose: An analytic Fourier approach to predict the expected number of counts registered in a photon‐counting detector subject to pulse pile‐up for arbitrary photon flux, detector response function, and pulse‐shape is presented. The analysis provides a complete forward model for energy‐sensitive, photon‐counting x‐ray detectors for spectral computed tomography.Methods: The formalism of the stochastic theory of the expected frequency of level crossings of shot noise processes is applied to the pulse pile‐up effect and build on a recently published analytic Fourier representation of the level crossing frequency of shot noise processes with piece‐wise continuous kernels with jumps.Results: The general analytic result is validated by a Monte Carlo simulation for pulses of the form g(t) = e−t/τ (t > 0) and a Gaussian detector response function. The Monte Carlo simulations are in excellent agreement with the analytic predictions of photon counts within the numerical accuracy of the calculations.Conclusions: The phenomenon of pulse pile‐up is identified with the level‐crossing problem of shot noise processes and an exact, analytic formula for the expected number of counts in energy‐sensitive, photon‐counting x‐ray detectors for arbitrary photon flux, response function, and pulse‐shapes is derived. The framework serves as a theoretical foundation for future works on pulse pile‐up.Keywords
This publication has 11 references indexed in Scilit:
- Crossings of smooth shot noise processesThe Annals of Applied Probability, 2012
- A Fourier Approach for the Level Crossings of Shot Noise Processes with JumpsJournal of Applied Probability, 2012
- Modeling the performance of a photon counting x‐ray detector for CT: Energy response and pulse pileup effectsMedical Physics, 2011
- An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x‐ray detectorsMedical Physics, 2010
- ChromAIX: a high-rate energy-resolving photon-counting ASIC for spectal computed tomography2010
- Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomographyPhysics in Medicine & Biology, 2008
- A generalized method for correcting pulse-height spectra for the peak pile-up effect due to double sum pulsesNuclear Instruments and Methods, 1977
- Prediction of the pulse-height spectral distortion caused by the peak pile-up effectNuclear Instruments and Methods, 1976
- Level-crossing problems for random processesIEEE Transactions on Information Theory, 1973
- Mathematical Analysis of Random NoiseBell System Technical Journal, 1945