Ewald Roessl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ewald Roessl has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Roland Proksa
Philips GmbH Innovative Technologies, Research Laboratories, 22335 Hamburg, Germany
4 shared publications - Gerhard Martens
Philips Research Labs. (Germany)
2 shared publications Roland Proksa
Philips GmbH Innovative Technologies, Philips Research Laboratories, Röntgenstrasse 24-26, D-22335 Hamburg, Germany
2 shared publications- Andy Ziegler
Philips Research Laboratories, Sector Technical Systems, Hamburg, Germany
1 shared publication Axel Thran
Philips Research Europe – Hamburg, Hamburg, Germany
1 shared publication- Axel Thran
Philips Research Europe—Hamburg, Digital Imaging, Röntgenstrasse 24–26, D-22335 Hamburg, Germany
1 shared publication
Latest Publications
- 17 February 2016
- Published by Wiley in Medical Physics
- Vol. 43 (3) , 1295-1298
A Fourier approach to pulse pile‐up in photon‐counting x‐ray detectors
Purpose: An analytic Fourier approach to predict the expected number of counts registered in a photon‐counting detector subject to pulse pile‐up for arbitrary photon flux, detector response function, and pulse‐shape is presented. The analysis provides a complete forward model for energy‐sensitive, photon‐counting x‐ray detectors for spectral computed tomography.Methods: The formalism of the stochastic theory of the expected frequency of level crossings of shot noise processes is applied to the pulse pile‐up effect and build on a recently published analytic Fourier representation of the level crossing frequency of shot noise processes with piece‐wise continuous kernels with jumps.Results: The general analytic result is validated by a Monte Carlo simulation for pulses of the form g(t) = e−t/τ (t > 0) and a Gaussian detector response function. The Monte Carlo simulations are in excellent agreement with the analytic predictions of photon counts within the numerical accuracy of the calculations.Conclusions: The phenomenon of pulse pile‐up is identified with the level‐crossing problem of shot noise processes and an exact, analytic formula for the expected number of counts in energy‐sensitive, photon‐counting x‐ray detectors for arbitrary photon flux, response function, and pulse‐shapes is derived. The framework serves as a theoretical foundation for future works on pulse pile‐up.
- 17 February 2016
- Published by Wiley in Medical Physics
- Vol. 43 (3) , 1295-1298
A Fourier approach to pulse pile‐up in photon‐counting x‐ray detectors
Purpose: An analytic Fourier approach to predict the expected number of counts registered in a photon‐counting detector subject to pulse pile‐up for arbitrary photon flux, detector response function, and pulse‐shape is presented. The analysis provides a complete forward model for energy‐sensitive, photon‐counting x‐ray detectors for spectral computed tomography.Methods: The formalism of the stochastic theory of the expected frequency of level crossings of shot noise processes is applied to the pulse pile‐up effect and build on a recently published analytic Fourier representation of the level crossing frequency of shot noise processes with piece‐wise continuous kernels with jumps.Results: The general analytic result is validated by a Monte Carlo simulation for pulses of the form g(t) = e−t/τ (t > 0) and a Gaussian detector response function. The Monte Carlo simulations are in excellent agreement with the analytic predictions of photon counts within the numerical accuracy of the calculations.Conclusions: The phenomenon of pulse pile‐up is identified with the level‐crossing problem of shot noise processes and an exact, analytic formula for the expected number of counts in energy‐sensitive, photon‐counting x‐ray detectors for arbitrary photon flux, response function, and pulse‐shapes is derived. The framework serves as a theoretical foundation for future works on pulse pile‐up.
- 6 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8668, 86680Z
Reconstruction method incorporating the object-position dependence of visibility loss in dark-field imaging
Dark-field imaging has the potential to overcome limitations in computed tomography (CT) investigating relatively weakly absorbing material. However, an object-position dependence of the visibility loss in dark-field imaging is observed. This effect might be negligible for small objects, but, for acquisition geometries using fanangle apertures and field of views as those in human CT scanners, the object-position dependence of visibility loss has to be taken into consideration if the scattering structure within the object is in the range of the grating periods, i.e. micrometer. This work examines the effect of object-position dependent visibility loss in dark-field imaging experimentally, investigates its consequences and presents an algorithm which solves the corresponding reconstruction problem.
- 6 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8668, 86680Z
Reconstruction method incorporating the object-position dependence of visibility loss in dark-field imaging
Dark-field imaging has the potential to overcome limitations in computed tomography (CT) investigating relatively weakly absorbing material. However, an object-position dependence of the visibility loss in dark-field imaging is observed. This effect might be negligible for small objects, but, for acquisition geometries using fanangle apertures and field of views as those in human CT scanners, the object-position dependence of visibility loss has to be taken into consideration if the scattering structure within the object is in the range of the grating periods, i.e. micrometer. This work examines the effect of object-position dependent visibility loss in dark-field imaging experimentally, investigates its consequences and presents an algorithm which solves the corresponding reconstruction problem.
- 10 November 2011
- Published by Wiley in Medical Physics
- Vol. 38 (12) , 6416-6428
A comparative study of a dual-energy-like imaging technique based on counting-integrating readout
The recent introduction of a specific electronic readout chip, designed for the processing of the same signal pulses from an x-ray sensor in one integrating and one counting channel in each pixel E. Kraft et al., [IEEE Trans. Nucl. Sci. 54, 383-390 (2007)]; E. Kraft, "Counting and integrating microelectronics development for direct conversion X-ray imaging," Ph.D. thesis, 2007; J. Fink, "Characterization of the imaging performance of the simultaneously counting and integrating X-ray detector CIX," Ph.D. thesis, 2010, enables an alternative to conventional dual-energy imaging methods. As shown in a previous paper, the proposed alternative benefits from positively correlated noise in the raw data, inherent to the counting-integrating readout (CIX), which results in a reduction of basis image noise after dual-energy decomposition. In the present paper, the authors compare the new approach to dual-energy imaging to two conventional dual-energy techniques, the dual-kV technique and the dual-crystal technique and to a photon-counting technique based on two energy windows. The study is based on x-ray computed tomography (CT) simulations of an anthropomorphic head phantom, where the signal-to-noise ratios and the contrast-to-noise ratios in basis material images and quasi-monochromatic images at 60 keV are compared. Moreover, a simple pictorial illustration of the relevance of input noise correlations in the noise-propagation process during the dual-energy basis material decomposition are presented, as well as measurement data for the correlation obtained as a function of the x-ray flux rate. Under the idealized assumptions of the absence of scatter and detector imperfections like K-escape, crosstalk and detector noise, our comparison shows that among the dual-energy techniques investigated, the CIX concept together with the dual-kV technique performs best, confirming the mitigating effect of correlated measurement data on the dual-energy basis material decomposition. The novel concept of simultaneous counting of photons and integrating the x-ray energy flux has a large potential for dual-energy applications in both projection and tomographic x-ray imaging. Future work will have to focus on the sensitivity of the CIX dual-energy concept to scattered radiation, detector imperfections and high x-ray fluxes.
- 10 November 2011
- Published by Wiley in Medical Physics
- Vol. 38 (12) , 6416-6428
A comparative study of a dual-energy-like imaging technique based on counting-integrating readout
The recent introduction of a specific electronic readout chip, designed for the processing of the same signal pulses from an x-ray sensor in one integrating and one counting channel in each pixel E. Kraft et al., [IEEE Trans. Nucl. Sci. 54, 383-390 (2007)]; E. Kraft, "Counting and integrating microelectronics development for direct conversion X-ray imaging," Ph.D. thesis, 2007; J. Fink, "Characterization of the imaging performance of the simultaneously counting and integrating X-ray detector CIX," Ph.D. thesis, 2010, enables an alternative to conventional dual-energy imaging methods. As shown in a previous paper, the proposed alternative benefits from positively correlated noise in the raw data, inherent to the counting-integrating readout (CIX), which results in a reduction of basis image noise after dual-energy decomposition. In the present paper, the authors compare the new approach to dual-energy imaging to two conventional dual-energy techniques, the dual-kV technique and the dual-crystal technique and to a photon-counting technique based on two energy windows. The study is based on x-ray computed tomography (CT) simulations of an anthropomorphic head phantom, where the signal-to-noise ratios and the contrast-to-noise ratios in basis material images and quasi-monochromatic images at 60 keV are compared. Moreover, a simple pictorial illustration of the relevance of input noise correlations in the noise-propagation process during the dual-energy basis material decomposition are presented, as well as measurement data for the correlation obtained as a function of the x-ray flux rate. Under the idealized assumptions of the absence of scatter and detector imperfections like K-escape, crosstalk and detector noise, our comparison shows that among the dual-energy techniques investigated, the CIX concept together with the dual-kV technique performs best, confirming the mitigating effect of correlated measurement data on the dual-energy basis material decomposition. The novel concept of simultaneous counting of photons and integrating the x-ray energy flux has a large potential for dual-energy applications in both projection and tomographic x-ray imaging. Future work will have to focus on the sensitivity of the CIX dual-energy concept to scattered radiation, detector imperfections and high x-ray fluxes.
- 1 August 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 648, S259-S264
Preclinical spectral computed tomography of gold nano-particles
- 1 August 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 648, S259-S264
Preclinical spectral computed tomography of gold nano-particles
- 15 April 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 30 (9) , 1678-1690
Sensitivity of Photon-Counting Based ${\rm K}$-Edge Imaging in X-ray Computed Tomography
The feasibility of K-edge imaging using energy-resolved, photon-counting transmission measurements in X-ray computed tomography (CT) has been demonstrated by simulations and experiments. The method is based on probing the discontinuities of the attenuation coefficient of heavy elements above and below the K-edge energy by using energy-sensitive, photon counting X-ray detectors. In this paper, we investigate the dependence of the sensitivity of K-edge imaging on the atomic number Z of the contrast material, on the object diameter D , on the spectral response of the X-ray detector and on the X-ray tube voltage. We assume a photon-counting detector equipped with six adjustable energy thresholds. Physical effects leading to a degradation of the energy resolution of the detector are taken into account using the concept of a spectral response function R(E,U) for which we assume four different models. As a validation of our analytical considerations and in order to investigate the influence of elliptically shaped phantoms, we provide CT simulations of an anthropomorphic Forbild-Abdomen phantom containing a gold-contrast agent. The dependence on the values of the energy thresholds is taken into account by optimizing the achievable signal-to-noise ratios (SNR) with respect to the threshold values. We find that for a given X-ray spectrum and object size the SNR in the heavy element's basis material image peaks for a certain atomic number Z. The dependence of the SNR in the high-Z basis-material image on the object diameter is the natural, exponential decrease with particularly deteriorating effects in the case where the attenuation from the object itself causes a total signal loss below the K-edge. The influence of the energy-response of the detector is very important. We observed that the optimal SNR values obtained with an ideal detector and with a CdTe pixel detector whose response, showing significant tailing, has been determined at a synchrotron differ by factors of about two to three. The potentially very important impact of scattered X-ray radiation and pulse pile-up occurring at high photon rates on the sensitivity of the technique is qualitatively discussed.
- 15 April 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 30 (9) , 1678-1690
Sensitivity of Photon-Counting Based ${\rm K}$-Edge Imaging in X-ray Computed Tomography
The feasibility of K-edge imaging using energy-resolved, photon-counting transmission measurements in X-ray computed tomography (CT) has been demonstrated by simulations and experiments. The method is based on probing the discontinuities of the attenuation coefficient of heavy elements above and below the K-edge energy by using energy-sensitive, photon counting X-ray detectors. In this paper, we investigate the dependence of the sensitivity of K-edge imaging on the atomic number Z of the contrast material, on the object diameter D , on the spectral response of the X-ray detector and on the X-ray tube voltage. We assume a photon-counting detector equipped with six adjustable energy thresholds. Physical effects leading to a degradation of the energy resolution of the detector are taken into account using the concept of a spectral response function R(E,U) for which we assume four different models. As a validation of our analytical considerations and in order to investigate the influence of elliptically shaped phantoms, we provide CT simulations of an anthropomorphic Forbild-Abdomen phantom containing a gold-contrast agent. The dependence on the values of the energy thresholds is taken into account by optimizing the achievable signal-to-noise ratios (SNR) with respect to the threshold values. We find that for a given X-ray spectrum and object size the SNR in the heavy element's basis material image peaks for a certain atomic number Z. The dependence of the SNR in the high-Z basis-material image on the object diameter is the natural, exponential decrease with particularly deteriorating effects in the case where the attenuation from the object itself causes a total signal loss below the K-edge. The influence of the energy-response of the detector is very important. We observed that the optimal SNR values obtained with an ideal detector and with a CdTe pixel detector whose response, showing significant tailing, has been determined at a synchrotron differ by factors of about two to three. The potentially very important impact of scattered X-ray radiation and pulse pile-up occurring at high photon rates on the sensitivity of the technique is qualitatively discussed.
- 3 February 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (5) , 1307-1318
Cramér–Rao lower bound of basis image noise in multiple-energy x-ray imaging
We present an analytical method to compute the basis image noise in the context of multi-energy x-ray imaging based on the Cramér-Rao lower bound (CRLB). The proposed formalism extends the original idea of Alvarez and Macovski (1976 Phys. Med. Biol. 21 733) to estimate the noise in the photo-effect and Compton-effect basis images in the case of dual-energy imaging. It includes an arbitrary number of independent, spectrally distinct attenuation measurements and also goes beyond the two-dimensional decomposition of the attenuation, including, e.g., a contrast agent as a third basis material. To illustrate our method, we consider three simple applications. The first application is to study the influence of the exact values for the energy thresholds on the basis image noise for a binned photon-counting system. The second application relates to the same detector system as the first and is an investigation of the dependence of the basis image noise on the energy resolution of the detector system. Finally, the third application provides an example for the case of an energy-integrating detector: the aim is to optimize the front-scintillator layer thickness of a dual-crystal detector for dual-energy imaging. The CRLB is used to minimize the noise of a photo-effect/Compton-effect basis material decomposition.
- 3 February 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (5) , 1307-1318
Cramér–Rao lower bound of basis image noise in multiple-energy x-ray imaging
We present an analytical method to compute the basis image noise in the context of multi-energy x-ray imaging based on the Cramér-Rao lower bound (CRLB). The proposed formalism extends the original idea of Alvarez and Macovski (1976 Phys. Med. Biol. 21 733) to estimate the noise in the photo-effect and Compton-effect basis images in the case of dual-energy imaging. It includes an arbitrary number of independent, spectrally distinct attenuation measurements and also goes beyond the two-dimensional decomposition of the attenuation, including, e.g., a contrast agent as a third basis material. To illustrate our method, we consider three simple applications. The first application is to study the influence of the exact values for the energy thresholds on the basis image noise for a binned photon-counting system. The second application relates to the same detector system as the first and is an investigation of the dependence of the basis image noise on the energy resolution of the detector system. Finally, the third application provides an example for the case of an energy-integrating detector: the aim is to optimize the front-scintillator layer thickness of a dual-crystal detector for dual-energy imaging. The CRLB is used to minimize the noise of a photo-effect/Compton-effect basis material decomposition.
- Top Cited Papers
- 17 July 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (15) , 4679-4696
K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors
After passage through matter, the energy spectrum of a polychromatic beam of x-rays contains valuable information about the elemental composition of the absorber. Conventional x-ray systems or x-ray computed tomography (CT) systems, equipped with scintillator detectors operated in the integrating mode, are largely insensitive to this type of spectral information, since the detector output is proportional to the energy fluence integrated over the whole spectrum. The main purpose of this paper is to investigate to which extent energy-sensitive photon counting devices, operated in the pulse-mode, are capable of revealing quantitative information about the elemental composition of the absorber. We focus on the detection of element-specific, K-edge discontinuities of the photo-electric cross-section. To be specific, we address the question of measuring and imaging the local density of a gadolinium-based contrast agent, in the framework of a generalized dual-energy pre-processing. Our results are very promising and seem to open up new possibilities for the imaging of the distribution of elements with a high atomic number Z in the human body using x-ray attenuation measurements. To demonstrate the usefulness of the detection and the appropriate processing of the spectral information, we present simulated images of an artherosclerotic coronary vessel filled with gadolinium-based contrast agent. While conventional systems, equipped with integrating detectors, often fail to differentiate between contrast filled lumen and artherosclerotic plaque, the use of an energy-selective detection system based on the counting of individual photons reveals a strong contrast between plaque and contrast agent.
- 17 July 2007
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (15) , 4679-4696
Top Cited PapersK-edge imaging in x-ray computed tomography using multi-bin photon counting detectors
After passage through matter, the energy spectrum of a polychromatic beam of x-rays contains valuable information about the elemental composition of the absorber. Conventional x-ray systems or x-ray computed tomography (CT) systems, equipped with scintillator detectors operated in the integrating mode, are largely insensitive to this type of spectral information, since the detector output is proportional to the energy fluence integrated over the whole spectrum. The main purpose of this paper is to investigate to which extent energy-sensitive photon counting devices, operated in the pulse-mode, are capable of revealing quantitative information about the elemental composition of the absorber. We focus on the detection of element-specific, K-edge discontinuities of the photo-electric cross-section. To be specific, we address the question of measuring and imaging the local density of a gadolinium-based contrast agent, in the framework of a generalized dual-energy pre-processing. Our results are very promising and seem to open up new possibilities for the imaging of the distribution of elements with a high atomic number Z in the human body using x-ray attenuation measurements. To demonstrate the usefulness of the detection and the appropriate processing of the spectral information, we present simulated images of an artherosclerotic coronary vessel filled with gadolinium-based contrast agent. While conventional systems, equipped with integrating detectors, often fail to differentiate between contrast filled lumen and artherosclerotic plaque, the use of an energy-selective detection system based on the counting of individual photons reveals a strong contrast between plaque and contrast agent.
- 15 February 2007
- Published by Wiley in Medical Physics
- Vol. 34 (3) , 959-966
On the influence of noise correlations in measurement data on basis image noise in dual‐energylike x‐ray imaging
In conventional dual-energy systems, two transmission measurements with distinct spectral characteristics are performed. These measurements are used to obtain the line integrals of two basis material densities. Usually, the measurement process is such that the two measured signals can be treated as independent and therefore uncorrelated. Recently, however, a readout system for x-ray detectors has been introduced for which this is no longer the case. The readout electronics is designed to obtain simultaneous measurements of the total number of photons N and the total energy E they deposit in the sensor material. Practically, this is realized by a signal replication and separate counting and integrating processing units. Since the quantities N and E are (electronically) derived from one and the same physical sensor signal, they are statistically correlated. Nevertheless, the pair N and E can be used to perform a dual-energy processing following the well-known approach by Alvarez and Macovski. Formally, this means that N is to be identified with the first dual-energy measurement M 1 and E with the second measurement M 2 . In the presence of input correlations between M 1 = N and M 2 = E , however, the corresponding analytic expressions for the basis imagenoise have to be modified. The main observation made in this paper is that for positively correlated data, as is the case for the simultaneous counting and integrating device mentioned above, the basis imagenoise is suppressed through the influence of the covariance between the two signals. We extend the previously published relations for the basis imagenoise to the case where the original measurements are not independent and illustrate the importance of the input correlations by comparing dual-energy basis imagenoise resulting from the device mentioned above and a device measuring the photon numbers and the deposited energies consecutively.
- 15 February 2007
- Published by Wiley in Medical Physics
- Vol. 34 (3) , 959-966
On the influence of noise correlations in measurement data on basis image noise in dual‐energylike x‐ray imaging
In conventional dual-energy systems, two transmission measurements with distinct spectral characteristics are performed. These measurements are used to obtain the line integrals of two basis material densities. Usually, the measurement process is such that the two measured signals can be treated as independent and therefore uncorrelated. Recently, however, a readout system for x-ray detectors has been introduced for which this is no longer the case. The readout electronics is designed to obtain simultaneous measurements of the total number of photons N and the total energy E they deposit in the sensor material. Practically, this is realized by a signal replication and separate counting and integrating processing units. Since the quantities N and E are (electronically) derived from one and the same physical sensor signal, they are statistically correlated. Nevertheless, the pair N and E can be used to perform a dual-energy processing following the well-known approach by Alvarez and Macovski. Formally, this means that N is to be identified with the first dual-energy measurement M 1 and E with the second measurement M 2 . In the presence of input correlations between M 1 = N and M 2 = E , however, the corresponding analytic expressions for the basis imagenoise have to be modified. The main observation made in this paper is that for positively correlated data, as is the case for the simultaneous counting and integrating device mentioned above, the basis imagenoise is suppressed through the influence of the covariance between the two signals. We extend the previously published relations for the basis imagenoise to the case where the original measurements are not independent and illustrate the importance of the input correlations by comparing dual-energy basis imagenoise resulting from the device mentioned above and a device measuring the photon numbers and the deposited energies consecutively.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1950-1954
Optimal energy threshold arrangement in photon-counting spectral x-ray imaging
We study the influence of the locations of energy thresholds on the basis image noise in spectral X-ray imaging using photon counting devices. Our simulations assume photon counting detectors equipped with up to four discriminator units allowing the binning of photons into up to four distinct energy windows. We use the binned counting data in order to compute the Cramer-Rao lower bound (CRB) for the basis image noise in a photo-effect -Compton-effect decomposition of the attenuation. By studying the variations of the CRB with respect to the threshold energies, we obtain optimized arrangements for each number of energy thresholds and for different values of external copper filtration. We compare the basis image noise for the optimal arrangement with the noise corresponding to an equidistant threshold arrangement and with the results of a tube dual-energy acquisition. Our simulations were performed on two different X-ray paths corresponding to two perpendicular directions through the human thorax. Our results show that in many cases the basis image noise can be strongly reduced by optimizing the locations of the threshold energies.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1950-1954
Optimal energy threshold arrangement in photon-counting spectral x-ray imaging
We study the influence of the locations of energy thresholds on the basis image noise in spectral X-ray imaging using photon counting devices. Our simulations assume photon counting detectors equipped with up to four discriminator units allowing the binning of photons into up to four distinct energy windows. We use the binned counting data in order to compute the Cramer-Rao lower bound (CRB) for the basis image noise in a photo-effect -Compton-effect decomposition of the attenuation. By studying the variations of the CRB with respect to the threshold energies, we obtain optimized arrangements for each number of energy thresholds and for different values of external copper filtration. We compare the basis image noise for the optimal arrangement with the noise corresponding to an equidistant threshold arrangement and with the results of a tube dual-energy acquisition. Our simulations were performed on two different X-ray paths corresponding to two perpendicular directions through the human thorax. Our results show that in many cases the basis image noise can be strongly reduced by optimizing the locations of the threshold energies.