SPIRE spinous process stabilization plate: biomechanical evaluation of a novel technology
Authors:
- 1 February 2006
- journal article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 4 (2) , 160-164
Abstract
Object: The authors studied the biomechanical properties of a novel spinous process stabilization plate (CD HORIZON SPIRE Spinal System) and present the results in comparison with those of other posterior fixation methods. Methods: Ten functional cadaveric lumbar segments were subjected to nondestructive quasistatic loading forces in 10 different conditions: intact, destabilized (discectomy), fitted with spinous process plate (SPP) alone, with anterior-column support (ACS) alone, ACS with SPP, ACS with posterior translaminar facet screw (PTFS) fixation, ACS with unilateral pedicle screw and rod (UPSR) fixation, ACS with bilateral pedicle screw and rod (BPSR) fixation, UPSR alone, or BPSR alone. Stiffness and range of motion (ROM) data were compared using a repeated-measures, one-way analysis of variance. The construct with greatest mean limitation of flexion–extension ROM was ACS/SPP at 4.14° whereas it was 5.75° for ACS/UPSR fixation, 5.03° for ACS/BPSR fixation, and 10.13° for the intact spine. The SPIRE plate alone also provided greater flexion and extension stiffness, with less ROM than other posterior stabilization options. Fixation with BPSR with or without ACS resulted in the stiffest construct in lateral bending and axial rotation. The SPP and UPSR fixation groups were equivalent in resisting lateral bending and axial rotation forces with or without ACS. Conclusions: The SPIRE plate effectively stabilized the spine, and the test results compare favorably with other fixation techniques that are more time consuming to perform and have greater inherent risks.Keywords
This publication has 11 references indexed in Scilit:
- Comparison of CD HORIZON SPIRE spinous process plate stabilization and pedicle screw fixation after anterior lumbar interbody fusionJournal of Neurosurgery: Spine, 2006
- Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operationsEuropean Spine Journal, 2002
- Stability of different wiring techniques in segmental spinal instrumentationArchives of orthopaedic and trauma surgery, 1998
- Complications Associated with the Technique of Pedicle Screw Fixation A Selected Survey of ABS MembersSpine, 1993
- Design and Evaluation of a Posterior Laminar Clamp Spinal Fixation SystemSpine, 1991
- Influence of Bone Mineral Density on the Fixation of Thoracolumbar Implants A Comparative Study of Transpedicular Screws, Laminar Hooks, and Spinous Process WiresSpine, 1990
- Biomechanical Comparison of Seven Internal Fixation Devices for the Lumbosacral JunctionSpine, 1987
- Interspinous Process Segmental Spinal InstrumentationJournal of Pediatric Orthopaedics, 1984
- Posterior spinal fusion using internal fixation with the Daab plateActa Orthopaedica, 1984
- Biography of Alfred Rives Shands, Jr., M.D.Clinical Orthopaedics and Related Research, 1971