JWJeremy C. Wang

Jeremy C. Wang

*This is an algorithmically generated author record based on publicly available information.

Jeremy C. Wang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • David Spenciner

    Atlanta Brain and Spine Care, Atlanta, Georgia; and RIH Orthopaedic Foundation, Inc., Providence, Rhode Island

    1 shared publication
  • James C. Robinson

    Atlanta Brain and Spine Care, Atlanta, Georgia; and RIH Orthopaedic Foundation, Inc., Providence, Rhode Island

    1 shared publication
  • James C. Robinson

    Mathematics Institute, University of Warwick, Coventry, UK

    1 shared publication
  • Jay S. Miller

    Atlanta Brain and Spine Care, Atlanta, Georgia; and Houston Spine and Neurosurgery Center, Houston, Texas

    1 shared publication
  • Regis W. Haid

    Atlanta Brain and Spine Care, Atlanta, Georgia; and Houston Spine and Neurosurgery Center, Houston, Texas

    1 shared publication

Latest Publications

  • Comparison of CD HORIZON SPIRE spinous process plate stabilization and pedicle screw fixation after anterior lumbar interbody fusion

    by Jeremy C. Wang, Regis W. Haid, Jay S. Miller, James C. Robinson

    The authors present the early clinical results obtained in patients who underwent SPIRE spinous process plate fixation following anterior lumbar interbody fusion (ALIF). Between May 2003 and January 2005, 32 patients underwent titanium cage and bone morphogenetic protein-augmented ALIF and subsequent SPIRE (21 cases) or bilateral pedicle screw (BPS; 11 cases) fixation. Pedicle screws were implanted using either the open approach (three cases) or using a tubular retractor (eight cases). Patients' charts were reviewed for operative time, estimated blood loss (EBL), hospital length of stay (LOS), and evidence of pseudarthrosis or hardware failure. In SPIRE plate-treated patients, the median EBL (75 ml) was lower than in BPS-treated patients (open BPS [150 ml]; tubular BPS [125 ml]). The median operative time in SPIRE plate-treated patients was also shorter (164 minutes compared with 239 and 250 minutes in the open and tubular BPS, respectively). The median LOS was 3 days for both the SPIRE and tubular BPS groups, but 4 days in the open BPS group. There were no instances of major surgery-induced complication, pseudarthrosis, or hardware failure during mean follow-up periods of 5.5, 7.2, and 4.9 months in the SPIRE, open PS, and tubular BPS groups, respectively. The SPIRE plate is easy to implant and is associated with minimal operative risk. Compared with BPS/rod constructs, SPIRE plate fixation leads to less EBL and shorter operative time, without an increase in the rate of pseudarthrosis. Hospital LOS was also shorter in SPIRE plate-treated patients, which is consistent with the goals of minimal access spinal technologies.


  • SPIRE spinous process stabilization plate: biomechanical evaluation of a novel technology

    by Jeremy C. Wang, David Spenciner, James C. Robinson

    Object: The authors studied the biomechanical properties of a novel spinous process stabilization plate (CD HORIZON SPIRE Spinal System) and present the results in comparison with those of other posterior fixation methods. Methods: Ten functional cadaveric lumbar segments were subjected to nondestructive quasistatic loading forces in 10 different conditions: intact, destabilized (discectomy), fitted with spinous process plate (SPP) alone, with anterior-column support (ACS) alone, ACS with SPP, ACS with posterior translaminar facet screw (PTFS) fixation, ACS with unilateral pedicle screw and rod (UPSR) fixation, ACS with bilateral pedicle screw and rod (BPSR) fixation, UPSR alone, or BPSR alone. Stiffness and range of motion (ROM) data were compared using a repeated-measures, one-way analysis of variance. The construct with greatest mean limitation of flexion–extension ROM was ACS/SPP at 4.14° whereas it was 5.75° for ACS/UPSR fixation, 5.03° for ACS/BPSR fixation, and 10.13° for the intact spine. The SPIRE plate alone also provided greater flexion and extension stiffness, with less ROM than other posterior stabilization options. Fixation with BPSR with or without ACS resulted in the stiffest construct in lateral bending and axial rotation. The SPP and UPSR fixation groups were equivalent in resisting lateral bending and axial rotation forces with or without ACS. Conclusions: The SPIRE plate effectively stabilized the spine, and the test results compare favorably with other fixation techniques that are more time consuming to perform and have greater inherent risks.