A Precise Calibration Method for Line Scan Cameras
- 27 July 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
Abstract
With the advantages of ultrahigh resolution and acquisition rate, line scan cameras are increasingly being deployed for precision measurement. In order to achieve high precision, the intrinsic parameters must be calibrated properly. However, the existing calibration models that only calibrate the principle points and the distortion on one-dimensional direction and ignore the other directions result in limited adaptability and accuracy, which are especially serious for multiline cameras. To conquer this challenge, this paper proposes a precise calibration method which is qualified both for multiline cameras and single-line cameras. Through the analysis of the relative position relationship between pixel array and principle point, a method for calibrating the principle points and the distortion on two-dimensional direction is proposed and a flexible calibration device is designed based on a theodolite. The calibration quality is improved by the novel calibration method which effectively establishes the correspondence relationship between the rays and pixels by recording incident angle of collimated beam and its image respectively. Moreover, a robust optimization algorithm is proposed to enhance the stability of parameter estimation. The proposed method is verified by Monte-Carlo simulation, real experimental data and flight, the results show that the two-dimensional calibration model can improve the calibration accuracy of the multiline cameras by 45 pixels at most and its re-projection measurement uncertainty is as low as 0.1 pixels. The comparative results of the experiments demonstrate that the proposed method has the advantages of high accuracy, low cost, and easy implementation.Keywords
Funding Information
- National Science and Technology Major Project of China (30-H32A01-9005-13/15)
This publication has 29 references indexed in Scilit:
- A calibration method of lens distortion for line scan camerasOptik, 2013
- Determination of line scan camera parameters via the direct linear transformationOptical Engineering, 2012
- A universal and flexible theodolite-camera system for making accurate measurements over large volumesOptics and Lasers in Engineering, 2012
- Plane-Based Calibration for Linear CamerasInternational Journal of Computer Vision, 2010
- Geometrical camera calibration with diffractive optical elementsOptics Express, 2008
- Determination and improvement of spatial resolution of the CCD-line-scanner system ADS40ISPRS Journal of Photogrammetry and Remote Sensing, 2006
- A flexible new technique for camera calibrationIEEE Transactions on Pattern Analysis and Machine Intelligence, 2000
- On single-scanline camera calibrationIEEE Transactions on Robotics and Automation, 1993
- Elimination of systematic error in subpixel accuracy centroid estimation [also Letter 34(11)3347-3348(Nov1995)]Optical Engineering, 1991
- Theory of Crossed Gratings1980