Yalin Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yalin Ding has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Guoqin Yuan
Key Laboratory of Airborne OpticalImaging and Measurement, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Science, Changchun,130033, China
1 shared publication - Hongwen Zhang
Key Laboratory of Airborne Optical Imaging and Measurement, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
1 shared publication - Jianjun Sun
Key Laboratory of Airborne OpticalImaging and Measurement, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Science, Changchun,130033, China
1 shared publication - Lina Zheng
Affiliation Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, Jilin, China
1 shared publication - Xuefei Zhang
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China
1 shared publication - Xueji Liu
Fine Mechanics and Physics
1 shared publication
Latest Publications
- 27 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
A Precise Calibration Method for Line Scan Cameras
With the advantages of ultrahigh resolution and acquisition rate, line scan cameras are increasingly being deployed for precision measurement. In order to achieve high precision, the intrinsic parameters must be calibrated properly. However, the existing calibration models that only calibrate the principle points and the distortion on one-dimensional direction and ignore the other directions result in limited adaptability and accuracy, which are especially serious for multiline cameras. To conquer this challenge, this paper proposes a precise calibration method which is qualified both for multiline cameras and single-line cameras. Through the analysis of the relative position relationship between pixel array and principle point, a method for calibrating the principle points and the distortion on two-dimensional direction is proposed and a flexible calibration device is designed based on a theodolite. The calibration quality is improved by the novel calibration method which effectively establishes the correspondence relationship between the rays and pixels by recording incident angle of collimated beam and its image respectively. Moreover, a robust optimization algorithm is proposed to enhance the stability of parameter estimation. The proposed method is verified by Monte-Carlo simulation, real experimental data and flight, the results show that the two-dimensional calibration model can improve the calibration accuracy of the multiline cameras by 45 pixels at most and its re-projection measurement uncertainty is as low as 0.1 pixels. The comparative results of the experiments demonstrate that the proposed method has the advantages of high accuracy, low cost, and easy implementation.
- 27 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
A Precise Calibration Method for Line Scan Cameras
With the advantages of ultrahigh resolution and acquisition rate, line scan cameras are increasingly being deployed for precision measurement. In order to achieve high precision, the intrinsic parameters must be calibrated properly. However, the existing calibration models that only calibrate the principle points and the distortion on one-dimensional direction and ignore the other directions result in limited adaptability and accuracy, which are especially serious for multiline cameras. To conquer this challenge, this paper proposes a precise calibration method which is qualified both for multiline cameras and single-line cameras. Through the analysis of the relative position relationship between pixel array and principle point, a method for calibrating the principle points and the distortion on two-dimensional direction is proposed and a flexible calibration device is designed based on a theodolite. The calibration quality is improved by the novel calibration method which effectively establishes the correspondence relationship between the rays and pixels by recording incident angle of collimated beam and its image respectively. Moreover, a robust optimization algorithm is proposed to enhance the stability of parameter estimation. The proposed method is verified by Monte-Carlo simulation, real experimental data and flight, the results show that the two-dimensional calibration model can improve the calibration accuracy of the multiline cameras by 45 pixels at most and its re-projection measurement uncertainty is as low as 0.1 pixels. The comparative results of the experiments demonstrate that the proposed method has the advantages of high accuracy, low cost, and easy implementation.