Effects of ultrasound irradiation on enzymatic hydrolysis of protein and application for the determination of tetracyclines in complex matrices
- 11 May 2017
- journal article
- research article
- Published by Wiley in Drug Testing and Analysis
- Vol. 9 (10) , 1586-1593
Abstract
The widespread use of tetracyclines (TCs) in food animals has led to concerns regarding unsafe residue levels in feed, food and manure. The determination of TCs in such matrices suffers from interference by the interactions between proteins and TCs. Three deproteination methods were compared in this study. In contrast with acid deproteination, which caused a large loss of TCs due to the strong adsorption of TCs on protein precipitates, a normal enzymatic hydrolysis was confirmed to have a merit of effectively releasing TCs from protein matrices, but required treatment time as long as 16 h. The adoption of ultrasound irradiation was proposed to shorten the enzymatic hydrolysis time. After investigating the effects of ultrasound power and irradiation time, the conditions of the ultrasound‐enhanced enzymatic hydrolysis were optimized as ultrasound power of 100 W and irradiation time of 6 min. The ultrasound‐enhanced enzymatic hydrolysis treatment of 6 min yielded recovery of TCs (from protein‐containing matrices) as high as that obtained by the normal enzymatic hydrolysis treatment of 16 h. The acceleration effect of ultrasound irradiation was attributed to ultrasound‐induced cavitation, which increased exposure of both the functional groups of trypsin and the C‐terminal amino acid in the protein that was a cleavage site for trypsin attack. When the ultrasound‐enhanced enzymatic hydrolysis method was used to determine TCs in complex matrices, it was found that this new method achieved recoveries of 89.5, 117.7, 110.4 and 100.0% for oxytetracycline, tetracycline, chlortetracycline and doxycycline, being much higher than those (29.6–39.4%) obtained using the common acid deproteination process. Copyright © 2017 John Wiley & Sons, Ltd.Keywords
Funding Information
- General Administration Quality Supervision and Quarantine of the PRC (T2015-HBQTS-0004)
This publication has 34 references indexed in Scilit:
- The determination of tetracycline residues in food using a disposable screen-printed gold electrode (SPGE)Sensors and Actuators B: Chemical, 2007
- Direct screening of tetracyclines in water and bovine milk using room temperature phosphorescence detectionAnalytica Chimica Acta, 2007
- Sonoreactor-Based Technology for Fast High-Throughput Proteolytic Digestion of ProteinsJournal of Proteome Research, 2006
- Determination of tetracycline residues in shrimp and whole milk using liquid chromatography with ultraviolet detection and residue confirmation by mass spectrometryAnalytica Chimica Acta, 2005
- Quantitative multi-residue analysis of tetracyclines and their 4-epimers in pig tissues by high-performance liquid chromatography combined with positive-ion electrospray ionization mass spectrometryAnalytica Chimica Acta, 2003
- Study of the interaction between terazosin and serum albuminAnalytica Chimica Acta, 2002
- Spectrofluorimetric determination of tetracycline and anhydrotetracycline in serum and urineThe Analyst, 1992
- Ionic alkylleads in herring gulls from the Great Lakes regionEnvironmental Science & Technology, 1986
- The determination of cadmium, copper, lead and thallium in human liver and kidney tissue by flame atomic absorption spectrometry after enzymatic digestionAnalytica Chimica Acta, 1981
- Fluorimetric determination of tetracyclines in biological materialsThe Analyst, 1976