Qian Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qian Zhou has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Hong Wang
Hubei Institute of Quality Supervision and Inspection, Wuhan, China
3 shared publications- Lihua Zhu
College of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
3 shared publications Cong Yao
Hubei Institute of Quality Supervision and Inspection, Wuhan, China
2 shared publicationsJin Peng
Hubei Research Institute of Products Quality Supervision and Inspection, Wuhan, People’s Republic of China
2 shared publicationsKuanzheng Zhu
Hubei Research Institute of Products Quality Supervision and Inspection, Wuhan, People’s Republic of China
2 shared publicationsShengyin Zhou
Hubei Research Institute of Products Quality Supervision and Inspection, Wuhan, People’s Republic of China
2 shared publications
Latest Publications
- Open Access
- 29 November 2022
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 10, 959176
Development and psychometric evaluation of the trauma nurse core competency scale
Background: Trauma, especially severe trauma, has become a significant public health problem worldwide. This postulates higher requirements on the core competence of trauma nurses. However, limited scales exist to assess it validly and reliably. This study aims to develop and evaluate the psychometric properties of the Trauma Nurse Core Competency Scale (TNCCS).Methods: This study included three stages. First, scale development was based on a broad literature review and two rounds of Delphi expert consultation. Then, a pre-investigation was conducted with 106 trauma nurses, and a formal scale was formed. Finally, scale evaluation of reliability and validity, based on a cross-sectional study, was tested with 1,107 trauma nurses. Content validity and structure validity were used to evaluate the validity of TNCCS. The Cronbach's α coefficient and the split-half reliability coefficient were used to evaluate the reliability of TNCCS.Results: The final scale contained 46 items under three dimensions, which were Knowledge and skills (21 items), Comprehensive literacy (20 items), and Professionalism & physical and mental health (5 items). The Content Validity Index (CVI) of the total scale was 0.980. The goodness-of-fit indices (χ2/df = 3.547, RMSEA = 0.065, GFI = 0.929, CFI = 0.912, NFI = 0.904, IFI = 0.929) signified a good fit for this model. The Construct Reliability (CR) ranged from 0.89 to 0.98, and the Average Variance Extracted (AVE) ranged from 0.62 to 0.69. The Cronbach's α coefficient of the scale was 0.99, ranging from 0.90 to 0.98 for the subscales. The split-half reliability coefficient was 0.84.Conclusions: The TNCCS demonstrated good validity and reliability, and it could be used to assess the core competency of trauma nurses. The present study has valuable implications for nursing managers to take corresponding measures to train and improve the core competence of trauma nurses.
- 29 November 2022
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 10, 959176
Open AccessDevelopment and psychometric evaluation of the trauma nurse core competency scale
Background: Trauma, especially severe trauma, has become a significant public health problem worldwide. This postulates higher requirements on the core competence of trauma nurses. However, limited scales exist to assess it validly and reliably. This study aims to develop and evaluate the psychometric properties of the Trauma Nurse Core Competency Scale (TNCCS).Methods: This study included three stages. First, scale development was based on a broad literature review and two rounds of Delphi expert consultation. Then, a pre-investigation was conducted with 106 trauma nurses, and a formal scale was formed. Finally, scale evaluation of reliability and validity, based on a cross-sectional study, was tested with 1,107 trauma nurses. Content validity and structure validity were used to evaluate the validity of TNCCS. The Cronbach's α coefficient and the split-half reliability coefficient were used to evaluate the reliability of TNCCS.Results: The final scale contained 46 items under three dimensions, which were Knowledge and skills (21 items), Comprehensive literacy (20 items), and Professionalism & physical and mental health (5 items). The Content Validity Index (CVI) of the total scale was 0.980. The goodness-of-fit indices (χ2/df = 3.547, RMSEA = 0.065, GFI = 0.929, CFI = 0.912, NFI = 0.904, IFI = 0.929) signified a good fit for this model. The Construct Reliability (CR) ranged from 0.89 to 0.98, and the Average Variance Extracted (AVE) ranged from 0.62 to 0.69. The Cronbach's α coefficient of the scale was 0.99, ranging from 0.90 to 0.98 for the subscales. The split-half reliability coefficient was 0.84.Conclusions: The TNCCS demonstrated good validity and reliability, and it could be used to assess the core competency of trauma nurses. The present study has valuable implications for nursing managers to take corresponding measures to train and improve the core competence of trauma nurses.
- 27 April 2022
- Published by Springer Nature in Food Analytical Methods
- Vol. 15 (9) , 2496-2504
Fast Online Solid Phase Extraction of Antibiotics by Click Chemistry Strategy Using Phenyl-Modified Periodic Mesoporous Organosilicas for Enrichment
- 27 April 2022
- Published by Springer Nature in Food Analytical Methods
- Vol. 15 (9) , 2496-2504
Fast Online Solid Phase Extraction of Antibiotics by Click Chemistry Strategy Using Phenyl-Modified Periodic Mesoporous Organosilicas for Enrichment
- 9 September 2020
- Published by Springer Nature in Food Analytical Methods
- Vol. 14 (1) , 28-35
Evaluation of Hydroxyapatite as Adsorbent in the Analysis of Trace Tetracyclines in Complex Matrices
- 9 September 2020
- Published by Springer Nature in Food Analytical Methods
- Vol. 14 (1) , 28-35
Evaluation of Hydroxyapatite as Adsorbent in the Analysis of Trace Tetracyclines in Complex Matrices
- 11 May 2017
- Published by Wiley in Drug Testing and Analysis
- Vol. 9 (10) , 1586-1593
Effects of ultrasound irradiation on enzymatic hydrolysis of protein and application for the determination of tetracyclines in complex matrices
The widespread use of tetracyclines (TCs) in food animals has led to concerns regarding unsafe residue levels in feed, food and manure. The determination of TCs in such matrices suffers from interference by the interactions between proteins and TCs. Three deproteination methods were compared in this study. In contrast with acid deproteination, which caused a large loss of TCs due to the strong adsorption of TCs on protein precipitates, a normal enzymatic hydrolysis was confirmed to have a merit of effectively releasing TCs from protein matrices, but required treatment time as long as 16 h. The adoption of ultrasound irradiation was proposed to shorten the enzymatic hydrolysis time. After investigating the effects of ultrasound power and irradiation time, the conditions of the ultrasound‐enhanced enzymatic hydrolysis were optimized as ultrasound power of 100 W and irradiation time of 6 min. The ultrasound‐enhanced enzymatic hydrolysis treatment of 6 min yielded recovery of TCs (from protein‐containing matrices) as high as that obtained by the normal enzymatic hydrolysis treatment of 16 h. The acceleration effect of ultrasound irradiation was attributed to ultrasound‐induced cavitation, which increased exposure of both the functional groups of trypsin and the C‐terminal amino acid in the protein that was a cleavage site for trypsin attack. When the ultrasound‐enhanced enzymatic hydrolysis method was used to determine TCs in complex matrices, it was found that this new method achieved recoveries of 89.5, 117.7, 110.4 and 100.0% for oxytetracycline, tetracycline, chlortetracycline and doxycycline, being much higher than those (29.6–39.4%) obtained using the common acid deproteination process. Copyright © 2017 John Wiley & Sons, Ltd.
- 11 May 2017
- Published by Wiley in Drug Testing and Analysis
- Vol. 9 (10) , 1586-1593
Effects of ultrasound irradiation on enzymatic hydrolysis of protein and application for the determination of tetracyclines in complex matrices
The widespread use of tetracyclines (TCs) in food animals has led to concerns regarding unsafe residue levels in feed, food and manure. The determination of TCs in such matrices suffers from interference by the interactions between proteins and TCs. Three deproteination methods were compared in this study. In contrast with acid deproteination, which caused a large loss of TCs due to the strong adsorption of TCs on protein precipitates, a normal enzymatic hydrolysis was confirmed to have a merit of effectively releasing TCs from protein matrices, but required treatment time as long as 16 h. The adoption of ultrasound irradiation was proposed to shorten the enzymatic hydrolysis time. After investigating the effects of ultrasound power and irradiation time, the conditions of the ultrasound‐enhanced enzymatic hydrolysis were optimized as ultrasound power of 100 W and irradiation time of 6 min. The ultrasound‐enhanced enzymatic hydrolysis treatment of 6 min yielded recovery of TCs (from protein‐containing matrices) as high as that obtained by the normal enzymatic hydrolysis treatment of 16 h. The acceleration effect of ultrasound irradiation was attributed to ultrasound‐induced cavitation, which increased exposure of both the functional groups of trypsin and the C‐terminal amino acid in the protein that was a cleavage site for trypsin attack. When the ultrasound‐enhanced enzymatic hydrolysis method was used to determine TCs in complex matrices, it was found that this new method achieved recoveries of 89.5, 117.7, 110.4 and 100.0% for oxytetracycline, tetracycline, chlortetracycline and doxycycline, being much higher than those (29.6–39.4%) obtained using the common acid deproteination process. Copyright © 2017 John Wiley & Sons, Ltd.