Design of an intraocular pressure curve protocol for use in dogs
Authors:
- 9 November 2016
- journal article
- Published by Wiley in Journal of Small Animal Practice
- Vol. 58 (1) , 42-48
Abstract
Objectives: To establish an intraocular pressure curve protocol that is safe for corneal health and detects harmful elevations of intraocular pressure outside normal clinic hours. To determine inter‐user variability and if repeated measurements affect intraocular pressures.Materials and Methods: Intraocular pressures were measured in dogs with glaucoma using three protocols: Protocol 1 used applanation tonometry every 2 hours over a 24‐hour period; Protocols 2 and 3 used applanation or rebound tonometry, respectively, and measured intraocular pressures every 3 hours over a 30‐hour period. A total of 60 additional intraocular pressure curves from dogs with glaucoma and 20 from healthy dogs were then analysed for inter‐user variability.Results: A total of 128 intraocular pressure curves were determined in 30 dogs. Protocol 1 resulted in one ulcer in five pressure curves, Protocol 2 in one ulcer in 62 pressure curves and Protocol 3 in no ulcers in 61 pressure curves. Elevated intraocular pressures were detected on 61 occasions, of which 26 developed outside normal clinic hours. A total of 61 additional intraocular pressure curves revealed that repeated measurements had no effect on intraocular pressure.Clinical Significance: Protocol 3, using rebound tonometry every 3 hours for 30 hours is safe corneal health and identified elevated intraocular pressures outside normal clinic hours in 12 of 30 (40%) patients that single intraocular pressure measurement during consultation hours would not have identified. Intraocular pressure curves may be recommended for clinical practice and glaucoma studies.Keywords
This publication has 28 references indexed in Scilit:
- Comparison of two handheld applanation tonometers and the association of central corneal thickness, age, and intraocular pressure in normal and diseased canine eyesVeterinary Ophthalmology, 2014
- Daytime profile of the intraocular pressure and tear production in normal dogVeterinary Ophthalmology, 2009
- Intraocular pressure measurements throughout the 24 hCurrent Opinion in Ophthalmology, 2009
- Effect of body position on intraocular pressure in dogs without glaucomaAmerican Journal of Veterinary Research, 2008
- Circadian rhythm of intraocular pressure in catsVeterinary Ophthalmology, 2007
- Clinical Utility of Intraocular Pressure Monitoring Outside of Normal Office Hours in Patients With GlaucomaArchives of Ophthalmology (1950), 2006
- Comparison of the use of new handheld tonometers and established applanation tonometers in dogsAmerican Journal of Veterinary Research, 2006
- Factors for Glaucoma Progression and the Effect of TreatmentArchives of Ophthalmology (1950), 2003
- Reliability of intraocular pressure measurement with the Goldmann applanation tonometer in epidemiological studiesGraefe's Archive for Clinical and Experimental Ophthalmology, 1994
- EFFECT OF LOCAL ANESTHETICS ON REGENERATION OF CORNEAL EPITHELIUMArchives of Ophthalmology (1950), 1944