Clinical Validation of Point‐Source Corneal Topography in Keratoplasty
- 1 July 2011
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 88 (7) , E837-42
Abstract
Purpose.: To validate the clinical performance of point‐source corneal topography (PCT) in postpenetrating keratoplasty (PKP) eyes and to compare it with conventional Placido‐based topography. Methods.: Corneal elevation maps of the anterior corneal surface were obtained from 20 post‐PKP corneas using PCT (VU topographer, prototype; VU University Medical Center, Amsterdam, The Netherlands) and Placido‐based topography (Keratron, Optikon 2000, Rome, Italy). Corneal surface parameters are calculated in terms of radius and asphericity. Corneal aberrations were characterized using standard Zernike convention. An artificial surface with quadrafoil feature (SUMIPRO, Almelo, The Netherlands) was measured and used as a reference to assess instrument performance compared with the gold standard. Results.: The differences (mean ± std of PCT − Placido) found between the two types of topographers in measurements of post‐PKP eyes are 0.02 ± 0.21 mm (p = 0.64) for radius of curvature, 0.14 ± 0.49 (p = 0.23) for asphericity, −0.19 ± 1.67 μm (p = 0.61) for corneal astigmatism, −0.25 ± 1.34 μm (p = 0.41) for corneal coma, 0.23 ± 0.82 μm (p = 0.23) for corneal trefoil, and 0.15 ± 0.28 μm (p = 0.02) for corneal quadrafoil. The PCT measured the artificial surface more accurate (rms error 0.16 μm; 0.12 eq. Dpt.) than the Placido‐based topographer (rms error 1.50 μm; 1.15 eq. Dpt.). Conclusions.: PCT is more accurate than Placido‐based topography in measuring quadrafoil aberration.Keywords
This publication has 30 references indexed in Scilit:
- Corneal topography with Scheimpflug imaging and videokeratography: Comparative study of normal eyesJournal of Cataract & Refractive Surgery, 2009
- Performance in Specular Reflection and Slit‐Imaging Corneal TopographyOptometry and Vision Science, 2009
- An Improved Low Order Method for Corneal ReconstructionOptometry and Vision Science, 2008
- The Skew Ray Ambiguity in the Analysis of Videokeratoscopic DataOptometry and Vision Science, 2007
- Measuring total corneal power before and after laser in situ keratomileusis with high-speed optical coherence tomographyJournal of Cataract & Refractive Surgery, 2006
- The Skew Ray Issue in Ocular Aberration MeasurementOptometry and Vision Science, 2006
- Mathematical Model of a Placido Disk Keratometer and Its Implications for Recovery of Corneal TopographyOptometry and Vision Science, 1997
- Axial Curvature and the Skew Ray Error in Corneal TopographyOptometry and Vision Science, 1997
- Corneal Topography Reconstruction Algorithm that Avoids the Skew Ray Ambiguity and the Skew Ray ErrorOptometry and Vision Science, 1997
- Height Measurement of Astigmatic Test Surfaces by a Keratoscope That Uses Plane Geometry Surface ReconstructionAmerican Journal of Ophthalmology, 1996