Construction of a Solid Contact Polymeric Membrane Electrode for pH Measurements in Acidic Media

Authors:

Abstract
A recently new synthesized azo Schiff base was studied to characterize its ability as a cation carrier in PVC membrane solid contact electrode. The coated glassy carbon electrode (CGCE) prepared with the azo Schiff base showed excellent response characteristics to hydrogen ions. The electrode exhibited Nernstian slope of 58.8 mV/decade over a wide concentration range of H+ ion from 2.0 × 10−7 to 1.8 × 10−1 M. It possessed fast response time, satisfactory reproducibility, appropriate lifetime, and most importantly, good selectivity toward H+ relative to a wide variety of other cations. The cations that usually interfere in the function of pH glass electrode such as Na+ and K+ didn't show any significant interference on the response of the proposed electrode. The effect of different non-aqueous media on the response of electrode was investigated. The electrode was applied as an indicator electrode in acid-base titration. The applicability of the electrode was tested by determination of H+ in milk as a good matrix solution and the results were compared with those obtained by the glass pH-electrode.

This publication has 38 references indexed in Scilit: