Construction of a Solid Contact Polymeric Membrane Electrode for pH Measurements in Acidic Media
Authors:
- 30 October 2013
- journal article
- research article
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 161 (1) , B14-B18
Abstract
A recently new synthesized azo Schiff base was studied to characterize its ability as a cation carrier in PVC membrane solid contact electrode. The coated glassy carbon electrode (CGCE) prepared with the azo Schiff base showed excellent response characteristics to hydrogen ions. The electrode exhibited Nernstian slope of 58.8 mV/decade over a wide concentration range of H+ ion from 2.0 × 10−7 to 1.8 × 10−1 M. It possessed fast response time, satisfactory reproducibility, appropriate lifetime, and most importantly, good selectivity toward H+ relative to a wide variety of other cations. The cations that usually interfere in the function of pH glass electrode such as Na+ and K+ didn't show any significant interference on the response of the proposed electrode. The effect of different non-aqueous media on the response of electrode was investigated. The electrode was applied as an indicator electrode in acid-base titration. The applicability of the electrode was tested by determination of H+ in milk as a good matrix solution and the results were compared with those obtained by the glass pH-electrode.Keywords
This publication has 38 references indexed in Scilit:
- Development of a New Coated Graphite Phenylephrine Potentiometric Sensor and Its Applications to Pharmaceutical and Biological AnalysisElectroanalysis, 2011
- Synthesis of Novel Azo Schiff Bases and Their Antibacterial and Antifungal ActivitiesMolecules, 2004
- Glass and polymeric membrane electrodes for the measurement of pH in milk and cheeseTalanta, 2004
- Synthesis of 2-hydroxy-3-methoxy-5-(4-methoxyphenylazo) benzaldehyde. A new aldehyde for the preparation of biologically active molecules.Molbank, 2004
- Behavior of a Polypyrrole Solid Contact pH-Selective Electrode Based on Tertiary Amine Ionophores Containing Different Alkyl Chain Lengths between Nitrogen and aPhenyl GroupAnalytical Sciences, 2003
- Hydrogen ion selective electrode based on poly(1-aminoanthracene) filmAnalytica Chimica Acta, 1998
- Lipophilicity of tetraphenylborate derivatives as anionic sites in neutral carrier-based solvent polymeric membranes and lifetime of corresponding ion-selective electrochemical and optical sensorsAnalytica Chimica Acta, 1995
- Lipophilic and immobilized anionic additives in solvent polymeric membranes of cation-selective chemical sensorsAnalytica Chimica Acta, 1993
- Coated-wire ion-selective electrodesAnalytica Chimica Acta, 1986
- Lipophilic salts as membrane additives and their influence on the properties of macro- and micro-electrodes based on neutral carriersAnalytica Chimica Acta, 1985