Ultrashort echo time and zero echo time MRI at 7T
- 24 December 2015
- journal article
- research article
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 29 (3) , 359-370
Abstract
Objective Zero echo time (ZTE) and ultrashort echo time (UTE) pulse sequences for MRI offer unique advantages of being able to detect signal from rapidly decaying short-T2 tissue components. In this paper, we applied 3D ZTE and UTE pulse sequences at 7T to assess differences between these methods. Materials and methods We matched the ZTE and UTE pulse sequences closely in terms of readout trajectories and image contrast. Our ZTE used the water- and fat-suppressed solid-state proton projection imaging method to fill the center of k-space. Images from healthy volunteers obtained at 7T were compared qualitatively, as well as with SNR and CNR measurements for various ultrashort, short, and long-T2 tissues. Results We measured nearly identical contrast-to-noise and signal-to-noise ratios (CNR/SNR) in similar scan times between the two approaches for ultrashort, short, and long-T2 components in the brain, knee and ankle. In our protocol, we observed gradient fidelity artifacts in UTE, and our chosen flip angle and readout also resulted in shading artifacts in ZTE due to inadvertent spatial selectivity. These can be corrected by advanced reconstruction methods or with different chosen protocol parameters. Conclusion The applied ZTE and UTE pulse sequences achieved similar contrast and SNR efficiency for volumetric imaging of ultrashort-T2 components. Key differences include that ZTE is limited to volumetric imaging, but has substantially reduced acoustic noise levels during the scan. Meanwhile, UTE has higher acoustic noise levels and greater sensitivity to gradient fidelity, but offers more flexibility in image contrast and volume selection.Keywords
Funding Information
- National Institutes of Health (S10-RR026845)
- National Center for Research Resources (UCSF-CTSI (Grant Number UL1 RR024131))
- GE Healthcare
This publication has 44 references indexed in Scilit:
- Depiction of Achilles Tendon Microstructure In Vivo Using High-Resolution 3-Dimensional Ultrashort Echo-Time Magnetic Resonance Imaging at 7 TInvestigative Radiology, 2014
- Ultrashort echo time MR imaging with off‐resonance saturation for characterization of pathologically altered Achilles tendons at 3 TMagnetic Resonance in Medicine, 2012
- Comparison of two ultrashort echo time sequences for the quantification of T1 within phantom and human Achilles tendon at 3 TMagnetic Resonance in Medicine, 2012
- Regional variations of T2* in healthy and pathologic achilles tendon in vivo at 7 Tesla: Preliminary resultsMagnetic Resonance in Medicine, 2012
- Characterization of 1H NMR signal in human cortical bone for magnetic resonance imagingMagnetic Resonance in Medicine, 2010
- Quantitative Characterization of the Achilles Tendon in Cadaveric Specimens: T1 and T2* Measurements Using Ultrashort-TE MRI at 3 TAmerican Journal of Roentgenology, 2009
- Cortical Bone Water: In Vivo Quantification with Ultrashort Echo-Time MR ImagingRadiology, 2008
- Water‐ and fat‐suppressed proton projection MRI (WASPI) of rat femur boneMagnetic Resonance in Medicine, 2007
- Magnetic resonance imaging of cortical bone with ultrashort TE pulse sequencesMagnetic Resonance Imaging, 2005
- Magnetic resonance imaging of the Achilles tendon using ultrashort TE (UTE) pulse sequencesClinical Radiology, 2004