A dataset of paired auscultatory and oscillometric blood pressure measurements from routine clinical practice
Open Access
- 22 July 2026
- journal article
- dataset
- Published by Springer Nature in Scientific Data
- Vol. 13 (1)
Abstract
Non-invasive blood pressure (BP) assessment underpins hypertension screening and clinical decision-making, yet agreement between clinician auscultation and automated oscillometry remains imperfect, particularly in routine outpatient care. We introduce OSC-AUS-BPM, a real-world dataset of paired BP measurements collected during standard cardiology outpatient visits using a hybrid workflow that yields methodologically independent readings within the same cuff inflation-deflation cycle. Specifically, an experienced cardiologist recorded auscultatory systolic and diastolic BP (AUS) during device-controlled deflation before oscillometric results were displayed, while the device simultaneously produced oscillometric systolic, diastolic and mean BP (OSC) and heart rate, and stored the cuff-pressure trace from the measurement cycle. Each record is accompanied by contextual metadata to support stratified analyses, including age, sex, height, weight, BMI, arm circumference, cuff type, rhythm classification and physician-reported hypertension class. A semi-automated processing pipeline removed test-phase entries, screened implausible or logically inconsistent values, corrected only unambiguous typographical errors and flagged incomplete records. OSC-AUS-BPM enables benchmarking of non-invasive BP methods, quantification of OSC-AUS disagreement across clinically relevant subgroups, and signal-processing research leveraging the recorded pressure trace.Keywords
Funding Information
- State Environmental Fund of the Czech Republic (CZ.10.03.01/00/22_003/0000003)
- State Environmental Fund of the Czech Republic (CZ.10.03.01/00/22_003/0000003)
- State Environmental Fund of the Czech Republic (CZ.10.03.01/00/22_003/0000003)
- State Environmental Fund of the Czech Republic (CZ.10.03.01/00/22_003/0000003)
- State Environmental Fund of the Czech Republic (CZ.10.03.01/00/22_003/0000003)
- VSB - Technical University of Ostrava (SP2026/081)
- VSB - Technical University of Ostrava (SP2026/081)
- VSB - Technical University of Ostrava (SP2026/081)
- VSB - Technical University of Ostrava (SP2026/081)
- VSB - Technical University of Ostrava (SP2026/081)
This publication has 26 references indexed in Scilit:
- Continuous Blood Pressure Dataset Featuring Arrhythmia and Diverse Baselines for Blood Pressure Estimation2025
- Phonocardiogram signal dataset paired with blood pressure measurementsData in Brief, 2025
- Effects of Cuff Size on the Accuracy of Blood Pressure ReadingsJAMA Internal Medicine, 2023
- MIMIC-IV, a freely accessible electronic health record datasetScientific Data, 2023
- VitalDB, a high-fidelity multi-parameter vital signs database in surgical patientsScientific Data, 2022
- Autonomic aging – A dataset to quantify changes of cardiovascular autonomic function during healthy agingScientific Data, 2022
- Dataset supporting blood pressure prediction for the management of chronic hemodialysisScientific Data, 2019
- Accuracy of automated blood pressure measurements in the presence of atrial fibrillation: systematic review and meta-analysisJournal of Human Hypertension, 2019
- MIMIC-III, a freely accessible critical care databaseScientific Data, 2016
- Trending autoregulatory indices during treatment for traumatic brain injuryJournal of Clinical Monitoring and Computing, 2015