Martin Augustynek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Martin Augustynek has a total of 151 co-authors. Here are the top co-authors by number of shared publications:
- Marek Penhaker
Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, VSB—Technical University of Ostrava, 708 00 Ostrava, Czech Republic
50 shared publications - Jan Kubicek
Department of Cybernetics and Biomedical Engineering, VSB-Technical University of Ostrava, Ostrava, Czech Republic
32 shared publications - Martin Cerny
Faculty of Electrical Engineering and Computer Science, VSB—Technical University of Ostrava, 17. listopadu 15, 708 33 Ostrava-Poruba, Czech Republic
22 shared publications - Juraj Timkovic
Clinic of Ophthalmology University Hospital Ostrava Ostrava Czech Republic
8 shared publications - Alice Varysova
Department of Cybernetics and Biomedical Engineering VŠB–Technical University of Ostrava Ostrava Czech Republic
5 shared publications - David Korpas
VSB - Technical University of Ostrava
5 shared publications
Latest Publications
- Open Access
- 27 November 2026
- Published by Springer Nature in Scientific Data
Physiological signal dataset on meditation-induced relaxation: galvanic skin response, heart rate, and heart rate variability measurements
Background The aim of this study was to develop a comprehensive dataset of galvanic skin response (GSR), heart rate (HR), and heart rate variability (HRV) signals under conditions approximating a normal ANS state. Methods. Over a 30-day period, data were collected in both a telemetric laboratory apartment (HEALTH.Lab) and participants’ homes, enabling comparisons between controlled and naturalistic environments. The dataset includes GSR, HR, and HRV signals recorded from 14 participants aged 20–25 years, together with behavioural and health questionnaires. The dataset enables fine-grained analyses of meditation-induced changes in physiological and emotional regulation and provides a resource for research in psychology, neuroscience, stress management, and biofeedback development.
- 27 November 2026
- Published by Springer Nature in Scientific Data
Open AccessPhysiological signal dataset on meditation-induced relaxation: galvanic skin response, heart rate, and heart rate variability measurements
Background The aim of this study was to develop a comprehensive dataset of galvanic skin response (GSR), heart rate (HR), and heart rate variability (HRV) signals under conditions approximating a normal ANS state. Methods. Over a 30-day period, data were collected in both a telemetric laboratory apartment (HEALTH.Lab) and participants’ homes, enabling comparisons between controlled and naturalistic environments. The dataset includes GSR, HR, and HRV signals recorded from 14 participants aged 20–25 years, together with behavioural and health questionnaires. The dataset enables fine-grained analyses of meditation-induced changes in physiological and emotional regulation and provides a resource for research in psychology, neuroscience, stress management, and biofeedback development.
- Open Access
- 13 November 2026
- Published by Elsevier in Results in Engineering
Finite Element Stress-Strain Analysis of a Cardiac Pacemaker Casing under Controlled Compression
- 13 November 2026
- Published by Elsevier in Results in Engineering
Open AccessFinite Element Stress-Strain Analysis of a Cardiac Pacemaker Casing under Controlled Compression
- Open Access
- 22 July 2026
- Published by Springer Nature in Scientific Data
- Vol. 13 (1)
A dataset of paired auscultatory and oscillometric blood pressure measurements from routine clinical practice
Non-invasive blood pressure (BP) assessment underpins hypertension screening and clinical decision-making, yet agreement between clinician auscultation and automated oscillometry remains imperfect, particularly in routine outpatient care. We introduce OSC-AUS-BPM, a real-world dataset of paired BP measurements collected during standard cardiology outpatient visits using a hybrid workflow that yields methodologically independent readings within the same cuff inflation-deflation cycle. Specifically, an experienced cardiologist recorded auscultatory systolic and diastolic BP (AUS) during device-controlled deflation before oscillometric results were displayed, while the device simultaneously produced oscillometric systolic, diastolic and mean BP (OSC) and heart rate, and stored the cuff-pressure trace from the measurement cycle. Each record is accompanied by contextual metadata to support stratified analyses, including age, sex, height, weight, BMI, arm circumference, cuff type, rhythm classification and physician-reported hypertension class. A semi-automated processing pipeline removed test-phase entries, screened implausible or logically inconsistent values, corrected only unambiguous typographical errors and flagged incomplete records. OSC-AUS-BPM enables benchmarking of non-invasive BP methods, quantification of OSC-AUS disagreement across clinically relevant subgroups, and signal-processing research leveraging the recorded pressure trace.
- 22 July 2026
- Published by Springer Nature in Scientific Data
- Vol. 13 (1)
Open AccessA dataset of paired auscultatory and oscillometric blood pressure measurements from routine clinical practice
Non-invasive blood pressure (BP) assessment underpins hypertension screening and clinical decision-making, yet agreement between clinician auscultation and automated oscillometry remains imperfect, particularly in routine outpatient care. We introduce OSC-AUS-BPM, a real-world dataset of paired BP measurements collected during standard cardiology outpatient visits using a hybrid workflow that yields methodologically independent readings within the same cuff inflation-deflation cycle. Specifically, an experienced cardiologist recorded auscultatory systolic and diastolic BP (AUS) during device-controlled deflation before oscillometric results were displayed, while the device simultaneously produced oscillometric systolic, diastolic and mean BP (OSC) and heart rate, and stored the cuff-pressure trace from the measurement cycle. Each record is accompanied by contextual metadata to support stratified analyses, including age, sex, height, weight, BMI, arm circumference, cuff type, rhythm classification and physician-reported hypertension class. A semi-automated processing pipeline removed test-phase entries, screened implausible or logically inconsistent values, corrected only unambiguous typographical errors and flagged incomplete records. OSC-AUS-BPM enables benchmarking of non-invasive BP methods, quantification of OSC-AUS disagreement across clinically relevant subgroups, and signal-processing research leveraging the recorded pressure trace.
- Open Access
- 3 June 2026
- Published by MDPI AG in Audiology Research
- Vol. 16 (3) , 85
Correction: Mimra et al. Functional Near-Infrared Spectroscopy (fNIRS) in Objective Audiometry: A Scoping Review and Clinical Perspectives. Audiol. Res. 2026, 16, 3
- 3 June 2026
- Published by MDPI AG in Audiology Research
- Vol. 16 (3) , 85
Open AccessCorrection: Mimra et al. Functional Near-Infrared Spectroscopy (fNIRS) in Objective Audiometry: A Scoping Review and Clinical Perspectives. Audiol. Res. 2026, 16, 3
- Open Access
- 26 May 2026
- Published by Elsevier in SSRN Electronic Journal
Finite Element Stress–Strain Analysis of a Cardiac Pacemaker Casing Validated by Mechanical Testing
Objective To develop and experimentally validate a finite element (FE) model of a clinical cardiac pacemaker pulse generator casing and position the model within contemporary device-mechanics and model-credibility expectations. Methods A commercially used Guidant Contak Renewal TR-2 pacemaker was destructively analysed to obtain the geometry of the titanium housing, internal lithium–polymer battery and plastic supports. Housing composition was verified by emission spectroscopy and elastic parameters were taken from tabulated data, while an effective Young’s modulus of the encapsulated battery was derived from quasi-static compression testing, consistent with current homogenized component-modelling practice. The three-dimensional FE model was built in MSC Patran/MD Nastran using shell elements for the thin-walled housing and ribs and solid elements for the battery. Boundary conditions reproduced a quasi-static compression experiment with bonded steel loading plates up to a force level associated with temporary loss of function. Results The validated model reproduced the measured force–deflection response with a relative deviation of 6–15% at representative load levels. Displacement and von Mises stress fields identified mechanically critical regions, particularly near curvature transitions, welds and housing–battery contacts. Conclusions The validated FE model provides a mechanically realistic baseline for casing behaviour under external compression and supports design optimisation, safety-margin assessment and targeted mechanical test development, with explicit credibility limits aligned to its intended context of use.
- 26 May 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessFinite Element Stress–Strain Analysis of a Cardiac Pacemaker Casing Validated by Mechanical Testing
Objective To develop and experimentally validate a finite element (FE) model of a clinical cardiac pacemaker pulse generator casing and position the model within contemporary device-mechanics and model-credibility expectations. Methods A commercially used Guidant Contak Renewal TR-2 pacemaker was destructively analysed to obtain the geometry of the titanium housing, internal lithium–polymer battery and plastic supports. Housing composition was verified by emission spectroscopy and elastic parameters were taken from tabulated data, while an effective Young’s modulus of the encapsulated battery was derived from quasi-static compression testing, consistent with current homogenized component-modelling practice. The three-dimensional FE model was built in MSC Patran/MD Nastran using shell elements for the thin-walled housing and ribs and solid elements for the battery. Boundary conditions reproduced a quasi-static compression experiment with bonded steel loading plates up to a force level associated with temporary loss of function. Results The validated model reproduced the measured force–deflection response with a relative deviation of 6–15% at representative load levels. Displacement and von Mises stress fields identified mechanically critical regions, particularly near curvature transitions, welds and housing–battery contacts. Conclusions The validated FE model provides a mechanically realistic baseline for casing behaviour under external compression and supports design optimisation, safety-margin assessment and targeted mechanical test development, with explicit credibility limits aligned to its intended context of use.
- Open Access
- 8 May 2026
- Published by Wiley in Advanced Intelligent Systems
- Vol. 8 (7)
Retinal Vessel Segmentation: A Comprehensive Review From Classical Methods to Deep Learning Advances (1982–2025)
Over four decades of retinal vessel segmentation (RVS) research (1982–2025) are synthesized, tracing developments across classical image processing, traditional machine learning, and deep learning paradigms. A cross‐paradigm taxonomy is introduced that links computational methods with clinical interpretability and model generalization, addressing gaps identified in earlier surveys. A comparative meta‐analysis of 428 studies catalogs preprocessing and postprocessing techniques, segmentation architectures, and loss functions and assesses reported performance on benchmark datasets (DRIVE, STARE, CHASE_DB1, HRF) using 20 standardized evaluation metrics. Architectural trends, including residual‐enhanced U‐Nets, attention‐guided models, graph convolutional networks, and transformer‐based architectures (SGAT‐Net, MTPA‐UNet), correlate with measurable improvements in vessel continuity, topology preservation, and clinical reliability. Emerging interpretability strategies, including attention mapping, saliency visualization, and feature attribution, are examined for their ability to enhance clinical transparency and trust in automated RVS systems. Persistent challenges include cross‐dataset generalization, annotation scarcity, and limited clinical deployment of explainable models. A forward‐looking roadmap emphasizes domain adaptation, semi‐supervised and weakly‐supervised learning, and efficient architectures for clinical translation. By integrating quantitative evidence with a clinically grounded taxonomy, a novel perspective on RVS is provided, serving as a comprehensive reference for research and clinical adoption in precision ophthalmology.
- 8 May 2026
- Published by Wiley in Advanced Intelligent Systems
- Vol. 8 (7)
Open AccessRetinal Vessel Segmentation: A Comprehensive Review From Classical Methods to Deep Learning Advances (1982–2025)
Over four decades of retinal vessel segmentation (RVS) research (1982–2025) are synthesized, tracing developments across classical image processing, traditional machine learning, and deep learning paradigms. A cross‐paradigm taxonomy is introduced that links computational methods with clinical interpretability and model generalization, addressing gaps identified in earlier surveys. A comparative meta‐analysis of 428 studies catalogs preprocessing and postprocessing techniques, segmentation architectures, and loss functions and assesses reported performance on benchmark datasets (DRIVE, STARE, CHASE_DB1, HRF) using 20 standardized evaluation metrics. Architectural trends, including residual‐enhanced U‐Nets, attention‐guided models, graph convolutional networks, and transformer‐based architectures (SGAT‐Net, MTPA‐UNet), correlate with measurable improvements in vessel continuity, topology preservation, and clinical reliability. Emerging interpretability strategies, including attention mapping, saliency visualization, and feature attribution, are examined for their ability to enhance clinical transparency and trust in automated RVS systems. Persistent challenges include cross‐dataset generalization, annotation scarcity, and limited clinical deployment of explainable models. A forward‐looking roadmap emphasizes domain adaptation, semi‐supervised and weakly‐supervised learning, and efficient architectures for clinical translation. By integrating quantitative evidence with a clinically grounded taxonomy, a novel perspective on RVS is provided, serving as a comprehensive reference for research and clinical adoption in precision ophthalmology.
- Open Access
- 9 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Affective Computing
- Vol. PP (3) , 1-19
Emotion Recognition from Physiological Responses: Accessibility and Usability of Publicly Available Datasets
Emotion recognition from biological signals provides valuable complementary information that may support clinical monitoring, symptom tracking, and assessment of affective processes, although it is not used as an independent diagnostic method. Despite its potential, dataset usability is hindered by challenges in accessibility, licensing, and inclusion of neutral stimuli. Existing datasets primarily focus on either AI training or eliciting emotional responses, both crucial for advancing the field. This review systematically analyzes current datasets and offers recommendations for their improvement. Using the PRISMA methodology, six databases were searched with predefined keywords, yielding 2,679 records. After filtering, 43 studies were included. Datasets were assessed based on four criteria: inclusion of neutral stimuli, downloadability, licensing for commercial use, and emotion assessment methods. Analyzed modalities include visual, auditory, physiological, and multimodal datasets. Methodological rigor determined their relevance to emotion recognition research. Findings reveal significant limitations in dataset usability, such as restrictions to academic use, inconsistent inclusion of neutral stimuli, and variability in assessment methods. Multimodal datasets show promise but require refinement for real-time applications in clinical and technological contexts. This review highlights the urgent need for open-access datasets and standardized methodologies to drive innovation and practical applications in emotion recognition technologies.
- 9 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Affective Computing
- Vol. PP (3) , 1-19
Open AccessEmotion Recognition from Physiological Responses: Accessibility and Usability of Publicly Available Datasets
Emotion recognition from biological signals provides valuable complementary information that may support clinical monitoring, symptom tracking, and assessment of affective processes, although it is not used as an independent diagnostic method. Despite its potential, dataset usability is hindered by challenges in accessibility, licensing, and inclusion of neutral stimuli. Existing datasets primarily focus on either AI training or eliciting emotional responses, both crucial for advancing the field. This review systematically analyzes current datasets and offers recommendations for their improvement. Using the PRISMA methodology, six databases were searched with predefined keywords, yielding 2,679 records. After filtering, 43 studies were included. Datasets were assessed based on four criteria: inclusion of neutral stimuli, downloadability, licensing for commercial use, and emotion assessment methods. Analyzed modalities include visual, auditory, physiological, and multimodal datasets. Methodological rigor determined their relevance to emotion recognition research. Findings reveal significant limitations in dataset usability, such as restrictions to academic use, inconsistent inclusion of neutral stimuli, and variability in assessment methods. Multimodal datasets show promise but require refinement for real-time applications in clinical and technological contexts. This review highlights the urgent need for open-access datasets and standardized methodologies to drive innovation and practical applications in emotion recognition technologies.
- Top Cited PapersOpen Access
- 2 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-30
Advancements in Noninvasive Blood Pressure Measurement: A Comprehensive Review of Cuffed, Cuffless, and Contactless Methods
Recent advances in non-invasive blood pressure (BP) monitoring are transforming the field, offering alternatives to traditional cuff-based methods that are often limited by discomfort and intermittent measurement. Following PRISMA guidelines, this review systematically analyses studies published between 2020 and 2024, categorizing current BP measurement techniques into cuff-based, cuffless, and contactless methods. Special attention is given to emerging technologies such as photoplethysmography (PPG), electrocardiography (ECG), bioimpedance, radar sensing, and remote PPG (rPPG), as well as the integration of artificial intelligence (AI) for signal processing and BP estimation. The review evaluates the comparative performance, clinical relevance, and readiness for real-world application across modalities. While cuffless and contactless approaches show significant promise for continuous and user-friendly monitoring, their accuracy often depends on calibration, multimodal data fusion, and robust algorithm design. Ethical considerations related to unobtrusive monitoring are also discussed. This work highlights current limitations, identifies future research opportunities, and supports the development of next-generation, AI-driven BP monitoring systems suitable for both clinical and consumer use.
- 2 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-30
Top Cited PapersOpen AccessAdvancements in Noninvasive Blood Pressure Measurement: A Comprehensive Review of Cuffed, Cuffless, and Contactless Methods
Recent advances in non-invasive blood pressure (BP) monitoring are transforming the field, offering alternatives to traditional cuff-based methods that are often limited by discomfort and intermittent measurement. Following PRISMA guidelines, this review systematically analyses studies published between 2020 and 2024, categorizing current BP measurement techniques into cuff-based, cuffless, and contactless methods. Special attention is given to emerging technologies such as photoplethysmography (PPG), electrocardiography (ECG), bioimpedance, radar sensing, and remote PPG (rPPG), as well as the integration of artificial intelligence (AI) for signal processing and BP estimation. The review evaluates the comparative performance, clinical relevance, and readiness for real-world application across modalities. While cuffless and contactless approaches show significant promise for continuous and user-friendly monitoring, their accuracy often depends on calibration, multimodal data fusion, and robust algorithm design. Ethical considerations related to unobtrusive monitoring are also discussed. This work highlights current limitations, identifies future research opportunities, and supports the development of next-generation, AI-driven BP monitoring systems suitable for both clinical and consumer use.
- Open Access
- 19 December 2025
- Published by MDPI AG in Audiology Research
- Vol. 16 (1) , 3
Functional Near-Infrared Spectroscopy (fNIRS) in Objective Audiometry: A Scoping Review and Clinical Perspectives
Background: The objective assessment of hearing in non-cooperative populations, such as neonates, remains a challenge. While Brainstem Evoked Response Audiometry (BERA) is the gold standard, its sensitivity to motion artifacts necessitates alternatives. Objective: This scoping review maps the current literature on functional near-infrared spectroscopy (fNIRS) as a supplementary method in objective audiometry. Data Synthesis: fNIRS shows potential to detect cortical hemodynamic responses, particularly to complex stimuli like speech, which BERA cannot fully assess. Key advantages include motion tolerance and suitability for pediatric and cochlear implant populations. However, the literature reveals significant heterogeneity in stimulation protocols and data processing. Evidence suggests fNIRS is better suited for assessing higher-level auditory processing rather than replacing BERA for threshold estimation. Conclusions: fNIRS is a promising complementary tool. However, due to the lack of standardized protocols and large-scale validation studies, it is not yet a direct clinical replacement for BERA. Future work must focus on protocol standardization and establishing robust normative data.
- 19 December 2025
- Published by MDPI AG in Audiology Research
- Vol. 16 (1) , 3
Open AccessFunctional Near-Infrared Spectroscopy (fNIRS) in Objective Audiometry: A Scoping Review and Clinical Perspectives
Background: The objective assessment of hearing in non-cooperative populations, such as neonates, remains a challenge. While Brainstem Evoked Response Audiometry (BERA) is the gold standard, its sensitivity to motion artifacts necessitates alternatives. Objective: This scoping review maps the current literature on functional near-infrared spectroscopy (fNIRS) as a supplementary method in objective audiometry. Data Synthesis: fNIRS shows potential to detect cortical hemodynamic responses, particularly to complex stimuli like speech, which BERA cannot fully assess. Key advantages include motion tolerance and suitability for pediatric and cochlear implant populations. However, the literature reveals significant heterogeneity in stimulation protocols and data processing. Evidence suggests fNIRS is better suited for assessing higher-level auditory processing rather than replacing BERA for threshold estimation. Conclusions: fNIRS is a promising complementary tool. However, due to the lack of standardized protocols and large-scale validation studies, it is not yet a direct clinical replacement for BERA. Future work must focus on protocol standardization and establishing robust normative data.
- Open Access
- 2 December 2025
- Published by Elsevier in Measurement
- Vol. 261
Scoping review of subcutaneous glucose monitoring techniques
- 2 December 2025
- Published by Elsevier in Measurement
- Vol. 261
Open AccessScoping review of subcutaneous glucose monitoring techniques