Assessment of the antero-posterior and rotational stability of the anterior cruciate ligament analogue in a guided motion bi-cruciate stabilized total knee arthroplasty
Authors:
- 1 November 2009
- journal article
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 33 (8) , 610-615
Abstract
Abnormal knee kinematics and sagittal instability after most knee replacements are due in part to deficient anterior cruciate ligament (ACL) and posterior cruciate ligament (PCL) function. The guided motion bi-cruciate stabilized knee replacement aspires to stabilize the knee posteriorly and anteriorly by means of a cam-post mechanism. This investigation studies the ACL-stabilizing function of that mechanism in early flexion, and 25 knees that had undergone replacement with this implant were studied. Antero-posterior laxity at 15° flexion was adequately restored for 76% (16/21) of the knees (side-to-side difference <3 mm on KT assessment), and 72% (18/25) knees exhibited a positive pivot shift test. The findings of this study suggest excellent early clinical outcomes for this implant, but the goal of replicating ACL function has only been partially achieved.Keywords
This publication has 28 references indexed in Scilit:
- Evaluation of impingement of the anterior tibial post during gait in a posteriorly-stabilised total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2008
- Tibial Post Failures in a Condylar Posterior Cruciate Substituting Total Knee ArthroplastyThe Journal of Arthroplasty, 2008
- Reliability of the KT1000 arthrometer and the Lachman test in patients with an ACL ruptureThe Knee, 2008
- In vivo anterior tibial post contact after posterior stabilizing total knee arthroplastyJournal of Orthopaedic Research, 2007
- Influence of surface geometry and the cam-post mechanism on the kinematics of total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2005
- Anterior tibial post impingement in a posterior stabilized total knee arthroplastyJournal of Orthopaedic Research, 2005
- Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2002
- Anterior cruciate-retaining total knee arthroplastyThe Journal of Arthroplasty, 1996
- Primary repair plus intra-articular iliotibial band augmentation in the treatment of an acute anterior cruciate ligament ruptureArchives of orthopaedic and trauma surgery, 1996
- Kinematic in-vitro comparison between the normal knee and two techniques for reconstruction of the anterior cruciate ligamentClinical Biomechanics, 1993