Automatic assessment of stent neointimal coverage by intravascular optical coherence tomography
Open Access
- 24 July 2013
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 15 (2) , 195-200
Abstract
This study aimed to validate automatic intravascular optical coherence tomography (IVOCT) analysis for the evaluation of neointimal coverage in response to stent implantation. Fourteen stented segments in common iliac arteries, acquired from a total of seven adult male New Zealand White rabbits, were interrogated in vivo by IVOCT. Durable polymer everolimus-eluting stents (EES; Xience V, Abbott Vascular, Santa Clara, CA, USA) were used exclusively. Comparison with histology was made in a total of 63 pairs of images, where neointimal thickness over corresponding individual stent struts was assessed. A high correlation coefficient (R = 0.85, P < 0.001) was obtained by comparing automatic IVOCT analysis with histology. Moreover, Bland–Altman statistics showed good limits of agreement (LOAs) of ±45 µm, with an average difference of −10 µm. In addition, manual IVOCT assessment presented very similar results when compared with histology (R = 0.83, P < 0.001 and LOA = ±48 µm with an average difference of −8 µm). Therefore, a very high correlation value was found, comparing manual to automatic IVOCT measurements (R = 0.95, P < 0.001) together with good LOAs (±27 µm) and an average difference of −2 µm. The results of the study suggest that automatic IVOCT analysis is a reliable and accurate tool able to speed up current IVOCT analysis procedures. This would potentially allow for a better integration of IVOCT in clinical practice and clinical studies assessing vascular response to stent implantation in a large series of patients.Keywords
This publication has 11 references indexed in Scilit:
- Fully automatic three-dimensional visualization of intravascular optical coherence tomography images: methods and feasibility in vivoBiomedical Optics Express, 2012
- Consensus Standards for Acquisition, Measurement, and Reporting of Intravascular Optical Coherence Tomography StudiesJACC, 2012
- Serial Assessment of Coronary Artery Response to Paclitaxel-Eluting Stents Using Optical Coherence TomographyCirculation: Cardiovascular Interventions, 2012
- Automatic three-dimensional registration of intravascular optical coherence tomography imagesJournal of Biomedical Optics, 2012
- Accuracy of Optical Coherence Tomography in the Evaluation of Neointimal Coverage After Stent ImplantationJACC: Cardiovascular Imaging, 2010
- Three-Dimensional Coronary Artery Microscopy by Intracoronary Optical Frequency Domain ImagingJACC: Cardiovascular Imaging, 2008
- Pathological Correlates of Late Drug-Eluting Stent ThrombosisCirculation, 2007
- Safety and Efficacy of Sirolimus- and Paclitaxel-Eluting Coronary StentsNew England Journal of Medicine, 2007
- Drug-Eluting Stent and Coronary ThrombosisCirculation, 2007
- Comprehensive volumetric optical microscopy in vivoNature Medicine, 2006