Assessment of Damage and Physico-Mechanical Properties of DMD Samples Made of 12Cr18Ni10Ti Steel under Uniaxial Deformation Conditions

Authors:

Abstract
The effect of uniaxial deformation on the damage, structure, and physico-mechanical properties of 12Cr18Ni10Ti steel samples produced by direct metal deposition (DMD) was investigated. Input testing of the powder material was carried out; the granulometric composition and particle shape factor were determined. Samples from the central and outer zones, differing in residual porosity (0.25 and 0.67%, respectively), were cut from the printed blank. Stepwise mechanical tensile tests were performed to evaluate the true flow stress, microhardness, fractal dimension of the microstructure, acoustic parameters, and the volume fraction of the magnetic phase. Anisotropy of mechanical properties across the cross-section of the workpiece was established: the central zone has higher strength but lower plastic characteristics. A linear correlation between microhardness and true flow stress was revealed. It is shown that the fractal dimension of the microstructure decreases monotonically with increasing damage. It was found that the acoustic parameters (\({{D}_{C}}\), acoustic anisotropy (\(A\)), the propagation time of Rayleigh waves) and the volume fraction of the magnetic phase caused by the formation of deformation martensite demonstrate high sensitivity to damage accumulation. The results obtained justify the use of non-destructive acoustic and magnetic testing methods for diagnosing material degradation in 12Cr18Ni10Ti steel products obtained by the DMD method.

This publication has 19 references indexed in Scilit: