An in vitro study of the fixed edentulous implant guide using a novel approach to edentulous guided surgery using a developed two part screw
Author:
Open Access
- 9 January 2026
- journal article
- research article
- Published by Springer Nature in BDJ Open
- Vol. 12 (1) , 4
Abstract
Introduction: Accurate implant placement in edentulous patients remains a clinical challenge, particularly when using mucosa-supported guides, which are prone to positional errors. Aims: To evaluate the accuracy of implant placement using the Fixed Edentulous Implant Guide (FEIG), a screw-retained guide system, compared with a conventional mucosa-supported guide in an edentulous mandible model. Materials and methods: Ten anatomical mandibular models with simulated mucosa and bone were used. Forty dummy implants were placed using either the FEIG system or a conventional guide. Implant positions were virtually planned, and deviations were assessed by comparing the planned and actual positions using STL-based alignment and a custom measurement algorithm. Results: The FEIG system demonstrated significantly lower mean deviations at the coronal (0.45 ± 0.15 mm) and apical (0.28 ± 0.13 mm) levels compared with the conventional guide (1.22 ± 0.61 mm and 0.89 ± 0.39 mm, respectively; p < 0.001). Angular deviation was lower for the FEIG (1.99° ± 0.98) but not statistically significant ( p = 0.081). Conclusions: The FEIG method significantly improved the accuracy of implant placement in vitro compared to a conventional edentulous guide. Further in vivo studies are warranted to confirm its clinical applicability.Keywords
This publication has 46 references indexed in Scilit:
- A Prospective Study on the Accuracy of Mucosally Supported Stereolithographic Surgical Guides in Fully Edentulous MaxillaeClinical Implant Dentistry and Related Research, 2012
- Adult Dental Health Surveys: 40 years onBritish Dental Journal, 2011
- The Role of Cone-Beam Computed Tomography in the Planning and Placement of ImplantsThe Journal of the American Dental Association, 2010
- Integrating Three-Dimensional Digital Technologies for Comprehensive Implant DentistryThe Journal of the American Dental Association, 2010
- Computer-Assisted Surgery in the Edentulous Jaw Based on 3 Fixed Intraoral Reference PointsJournal of Oral and Maxillofacial Surgery, 2010
- Influence of dental status on nutritional status of geriatric patients in a convalescent and rehabilitation hospital.2006
- A Randomized Controlled Trial of Implant-retained Mandibular OverdenturesJournal of Dental Research, 2006
- The Neglected Global Burden of Chronic Oral DiseasesJournal of Dental Research, 2006
- Edentulousness in the United Kingdom and IrelandCommunity Dentistry and Oral Epidemiology, 1983
- Reduction of residual ridges: A major oral disease entityThe Journal of Prosthetic Dentistry, 1971