Soft hybrid intrinsically motile robot for wireless small bowel enteroscopy
Authors:
Open Access
- 31 January 2022
- journal article
- research article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 36 (6) , 4624-4630
Abstract
Background: Difficulties in establishing diagnosis of small bowel (SB) disorders, prevented their effective treatment. This problem was largely resolved by wireless capsule endoscopy (WCE), which has since become the first line investigation for suspected SB disorders. Several types of WCE pills are now used in clinical practice, despite their limitations and complications. WCE pills are large, rigid and immotile capsules. When swallowed, they provide SB enteroscopy downloaded to a data logger carried by the patient. Most of the complications of WCEs result from lack of intrinsic locomotion: incomplete examination, capsule retention and impaction within strictures. In addition, the rigid nature and size of current generation of WCE pills is accompanied by 0.1% inability to swallow the pill by patients with normal esophageal motility. Methods: The aim of this communication is to describe the initial prototype, P1, which is thinner and slightly longer than the current generation of WCEs. In addition, it exhibits intrinsic active locomotion, produced by vibrating silicon legs. These generate a controlled-skid locomotion on the small bowel mucosal surface, rendered slippery by surface mucus and intraluminal surfactant bile salts. We demonstrate the mechanism responsible for the active locomotion of P1, which we consider translatable into a working prototype, suitable for further R&D for eventual clinical translation. Results: The shape and attachment of the rubber vibrating legs to vibrating actuators, have been designed specifically to produce a tight clockwise circular motion. When inserted inside a circular tube in vitro of equivalent diameter to human small intestine, the intrinsic circular clockwise motion of P1 translates into a linear locomotion by the constraints imposed by the surrounding circular walls of SB and rest of the gastrointestinal tract. This design ensures device stability during transit, essential for imaging and targeting lesions encountered during the enteroscopy. We preformed two experiments: (i) transit of P1 through a phantom consisting of a segment of PVC tube placed on a horizontal surface and (ii) transit through a transparent slippery nylon sleeve insufflated with air. In the PVC tube, its transit rate averages 15.6 mm/s, which is too fast for endoscopy: whereas inside the very slippery nylon sleeve insufflated with air, the average transit rate of P1 is reduced to 5.9 mm/s, i.e., ideal for inspection endoscopy. Conclusions: These in-vitro experiments indicate that the P1 hybrid soft robot prototype has the potential specifically for clinical translation for SB enteroscopy.Keywords
Funding Information
- Wellcome Trust (218356/Z/19/Z)
This publication has 20 references indexed in Scilit:
- Modeling the high-frequency complex modulus of silicone rubber using standing lamb waves and an inverse finite element methodIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014
- Wireless capsule endoscopy of the small intestineCurrent Opinion in Gastroenterology, 2014
- OdoCapsule: Next-Generation Wireless Capsule Endoscopy With Accurate Lesion Localization and Video Stabilization CapabilitiesIEEE Transactions on Biomedical Engineering, 2014
- Application of Wireless Power Transmission Systems in Wireless Capsule Endoscopy: An OverviewSensors, 2014
- A review of drug delivery systems for capsule endoscopyAdvanced Drug Delivery Reviews, 2014
- Video capsule endoscopy: Perspectives of a revolutionary techniqueWorld Journal of Gastroenterology, 2014
- Capsule endoscopy: Current practice and future directionsWorld Journal of Gastroenterology, 2014
- Capsule endoscopy in patients refusing conventional endoscopyWorld Journal of Gastroenterology, 2014
- A wireless capsule robot with spiral legs for human intestineThe International Journal of Medical Robotics and Computer Assisted Surgery, 2013
- A Robotic Biopsy Device for Capsule EndoscopyJournal of Medical Devices, 2012