Hamza Khan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hamza Khan has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Claudio Semini
Istituto Italiano di Tecnologia
6 shared publications - Darwin Gordon Caldwell
Instituto Italiano di Tecnologia
6 shared publications - Alfred Cuschieri
Institute for Medical Science and Technology (IMSaT), University of Dundee, Wilson House, 1 Wurzburg Loan, Dundee Medipark, Dundee DD2 1FD, UK
2 shared publications - Ferdinando Cannella
Istituto Italiano di Tecnologia
2 shared publications Jamshed Iqbal
COMSATS Institute of Information Technology, Pakistan
2 shared publications- Jamshed Iqbal
School of Digital and Physical Sciences, Faculty of Science and Engineering, University of Hull, Hull HU6 7RX, UK
2 shared publications
Latest Publications
- Open Access
- 21 November 2023
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 110 (2) , 750-757
Force-adjustable parallel-occlusion grasper
Background: During laparoscopic surgery, the operating surgeon grasps sections of the gastrointestinal tract (GIT), including delicate structures, with long (270 mm) 5 mm diameter graspers. These grasping instruments increase the risk of iatrogenic damage due to crushing of the grasped tissue. This risk is increased significantly by diseases such as bacterial peritonitis and inflammatory bowel disease and reduced but not abolished by using parallel-closing laparoscopic instruments. This study describes the design and laboratory testing of fully developed and tested smart graspers capable of reducing the grasping force used for inflamed tissues and hollow viscera. Materials and methods: In an ISO 13485-certified mechanical laboratory and CAD machine workshop, the authors have designed, developed, and evaluated a smart gasper capable of exerting a preselected uniform grasping force on the gastrointestinal tract and other structures/ tissues, through a mechanism incorporated in the handle of the instrument. This enables the control and graded reduction of the grasping force by the incorporation of a compression spring. The authors named the new instrument the force-adjustable parallel-occlusion grasper (FA-POG) because, in addition to applying a uniform force on the grasped bowel/tissue, it also enables the surgeon to select the force before grasping, depending on its physical condition, and pathological state. Results: FA-POG differs from traditional pinch-occlusion grasper in two respects: it exerts a uniform force on the grasped tissue/bowel and enables the operating surgeon to select and apply a predetermined uniform grasping force, ranging from 1 to 5 N, depending on the pathological condition of the bowel/structure. The ISO 13485-certified and fully developed prototype has been subjected to various grasping in-vitro tests using freshly harvested porcine small-bowel segments obtained from a local abattoir, using Instron tensiometry. Conclusions: The authors designed and α/β tested a parallel-occlusion gasper that enables the operating surgeon to select the force before grasping. This grasper design consists of end-effectors jaws with a 4-bar linkage mechanism for wide, uniform parallel-occlusion force, surpassing traditional scissor-type laparoscopic graspers. It incorporates a force-level controller knob, based on a spring-loaded mechanism, enabling surgeon-preselected grip force to prevent excessive grasping. The authors validated the design experimentally using porcine small-bowel segments, optimizing teeth for maximum grip friction to minimize slippage.
- 21 November 2023
- Published by Wolters Kluwer Health in International Journal of Surgery
- Vol. 110 (2) , 750-757
Open AccessForce-adjustable parallel-occlusion grasper
Background: During laparoscopic surgery, the operating surgeon grasps sections of the gastrointestinal tract (GIT), including delicate structures, with long (270 mm) 5 mm diameter graspers. These grasping instruments increase the risk of iatrogenic damage due to crushing of the grasped tissue. This risk is increased significantly by diseases such as bacterial peritonitis and inflammatory bowel disease and reduced but not abolished by using parallel-closing laparoscopic instruments. This study describes the design and laboratory testing of fully developed and tested smart graspers capable of reducing the grasping force used for inflamed tissues and hollow viscera. Materials and methods: In an ISO 13485-certified mechanical laboratory and CAD machine workshop, the authors have designed, developed, and evaluated a smart gasper capable of exerting a preselected uniform grasping force on the gastrointestinal tract and other structures/ tissues, through a mechanism incorporated in the handle of the instrument. This enables the control and graded reduction of the grasping force by the incorporation of a compression spring. The authors named the new instrument the force-adjustable parallel-occlusion grasper (FA-POG) because, in addition to applying a uniform force on the grasped bowel/tissue, it also enables the surgeon to select the force before grasping, depending on its physical condition, and pathological state. Results: FA-POG differs from traditional pinch-occlusion grasper in two respects: it exerts a uniform force on the grasped tissue/bowel and enables the operating surgeon to select and apply a predetermined uniform grasping force, ranging from 1 to 5 N, depending on the pathological condition of the bowel/structure. The ISO 13485-certified and fully developed prototype has been subjected to various grasping in-vitro tests using freshly harvested porcine small-bowel segments obtained from a local abattoir, using Instron tensiometry. Conclusions: The authors designed and α/β tested a parallel-occlusion gasper that enables the operating surgeon to select the force before grasping. This grasper design consists of end-effectors jaws with a 4-bar linkage mechanism for wide, uniform parallel-occlusion force, surpassing traditional scissor-type laparoscopic graspers. It incorporates a force-level controller knob, based on a spring-loaded mechanism, enabling surgeon-preselected grip force to prevent excessive grasping. The authors validated the design experimentally using porcine small-bowel segments, optimizing teeth for maximum grip friction to minimize slippage.
- Open Access
- 31 January 2022
- Published by Springer Nature in Surgical Endoscopy
- Vol. 36 (6) , 4624-4630
Soft hybrid intrinsically motile robot for wireless small bowel enteroscopy
Background: Difficulties in establishing diagnosis of small bowel (SB) disorders, prevented their effective treatment. This problem was largely resolved by wireless capsule endoscopy (WCE), which has since become the first line investigation for suspected SB disorders. Several types of WCE pills are now used in clinical practice, despite their limitations and complications. WCE pills are large, rigid and immotile capsules. When swallowed, they provide SB enteroscopy downloaded to a data logger carried by the patient. Most of the complications of WCEs result from lack of intrinsic locomotion: incomplete examination, capsule retention and impaction within strictures. In addition, the rigid nature and size of current generation of WCE pills is accompanied by 0.1% inability to swallow the pill by patients with normal esophageal motility. Methods: The aim of this communication is to describe the initial prototype, P1, which is thinner and slightly longer than the current generation of WCEs. In addition, it exhibits intrinsic active locomotion, produced by vibrating silicon legs. These generate a controlled-skid locomotion on the small bowel mucosal surface, rendered slippery by surface mucus and intraluminal surfactant bile salts. We demonstrate the mechanism responsible for the active locomotion of P1, which we consider translatable into a working prototype, suitable for further R&D for eventual clinical translation. Results: The shape and attachment of the rubber vibrating legs to vibrating actuators, have been designed specifically to produce a tight clockwise circular motion. When inserted inside a circular tube in vitro of equivalent diameter to human small intestine, the intrinsic circular clockwise motion of P1 translates into a linear locomotion by the constraints imposed by the surrounding circular walls of SB and rest of the gastrointestinal tract. This design ensures device stability during transit, essential for imaging and targeting lesions encountered during the enteroscopy. We preformed two experiments: (i) transit of P1 through a phantom consisting of a segment of PVC tube placed on a horizontal surface and (ii) transit through a transparent slippery nylon sleeve insufflated with air. In the PVC tube, its transit rate averages 15.6 mm/s, which is too fast for endoscopy: whereas inside the very slippery nylon sleeve insufflated with air, the average transit rate of P1 is reduced to 5.9 mm/s, i.e., ideal for inspection endoscopy. Conclusions: These in-vitro experiments indicate that the P1 hybrid soft robot prototype has the potential specifically for clinical translation for SB enteroscopy.
- 31 January 2022
- Published by Springer Nature in Surgical Endoscopy
- Vol. 36 (6) , 4624-4630
Open AccessSoft hybrid intrinsically motile robot for wireless small bowel enteroscopy
Background: Difficulties in establishing diagnosis of small bowel (SB) disorders, prevented their effective treatment. This problem was largely resolved by wireless capsule endoscopy (WCE), which has since become the first line investigation for suspected SB disorders. Several types of WCE pills are now used in clinical practice, despite their limitations and complications. WCE pills are large, rigid and immotile capsules. When swallowed, they provide SB enteroscopy downloaded to a data logger carried by the patient. Most of the complications of WCEs result from lack of intrinsic locomotion: incomplete examination, capsule retention and impaction within strictures. In addition, the rigid nature and size of current generation of WCE pills is accompanied by 0.1% inability to swallow the pill by patients with normal esophageal motility. Methods: The aim of this communication is to describe the initial prototype, P1, which is thinner and slightly longer than the current generation of WCEs. In addition, it exhibits intrinsic active locomotion, produced by vibrating silicon legs. These generate a controlled-skid locomotion on the small bowel mucosal surface, rendered slippery by surface mucus and intraluminal surfactant bile salts. We demonstrate the mechanism responsible for the active locomotion of P1, which we consider translatable into a working prototype, suitable for further R&D for eventual clinical translation. Results: The shape and attachment of the rubber vibrating legs to vibrating actuators, have been designed specifically to produce a tight clockwise circular motion. When inserted inside a circular tube in vitro of equivalent diameter to human small intestine, the intrinsic circular clockwise motion of P1 translates into a linear locomotion by the constraints imposed by the surrounding circular walls of SB and rest of the gastrointestinal tract. This design ensures device stability during transit, essential for imaging and targeting lesions encountered during the enteroscopy. We preformed two experiments: (i) transit of P1 through a phantom consisting of a segment of PVC tube placed on a horizontal surface and (ii) transit through a transparent slippery nylon sleeve insufflated with air. In the PVC tube, its transit rate averages 15.6 mm/s, which is too fast for endoscopy: whereas inside the very slippery nylon sleeve insufflated with air, the average transit rate of P1 is reduced to 5.9 mm/s, i.e., ideal for inspection endoscopy. Conclusions: These in-vitro experiments indicate that the P1 hybrid soft robot prototype has the potential specifically for clinical translation for SB enteroscopy.
- Open Access
Towards Scalable Strain Gauge-Based Joint Torque Sensors
During recent decades, strain gauge-based joint torque sensors have been commonly used to provide high-fidelity torque measurements in robotics. Although measurement of joint torque/force is often required in engineering research and development, the gluing and wiring of strain gauges used as torque sensors pose difficulties during integration within the restricted space available in small joints. The problem is compounded by the need for a scalable geometric design to measure joint torque. In this communication, we describe a novel design of a strain gauge-based mono-axial torque sensor referred to as square-cut torque sensor (SCTS), the significant features of which are high degree of linearity, symmetry, and high scalability in terms of both size and measuring range. Most importantly, SCTS provides easy access for gluing and wiring of the strain gauges on sensor surface despite the limited available space. We demonstrated that the SCTS was better in terms of symmetry (clockwise and counterclockwise rotation) and more linear. These capabilities have been shown through finite element modeling (ANSYS) confirmed by observed data obtained by load testing experiments. The high performance of SCTS was confirmed by studies involving changes in size, material and/or wings width and thickness. Finally, we demonstrated that the SCTS can be successfully implementation inside the hip joints of miniaturized hydraulically actuated quadruped robot-MiniHyQ. This communication is based on work presented at the 18th International Conference on Climbing and Walking Robots (CLAWAR).
Open AccessTowards Scalable Strain Gauge-Based Joint Torque Sensors
During recent decades, strain gauge-based joint torque sensors have been commonly used to provide high-fidelity torque measurements in robotics. Although measurement of joint torque/force is often required in engineering research and development, the gluing and wiring of strain gauges used as torque sensors pose difficulties during integration within the restricted space available in small joints. The problem is compounded by the need for a scalable geometric design to measure joint torque. In this communication, we describe a novel design of a strain gauge-based mono-axial torque sensor referred to as square-cut torque sensor (SCTS), the significant features of which are high degree of linearity, symmetry, and high scalability in terms of both size and measuring range. Most importantly, SCTS provides easy access for gluing and wiring of the strain gauges on sensor surface despite the limited available space. We demonstrated that the SCTS was better in terms of symmetry (clockwise and counterclockwise rotation) and more linear. These capabilities have been shown through finite element modeling (ANSYS) confirmed by observed data obtained by load testing experiments. The high performance of SCTS was confirmed by studies involving changes in size, material and/or wings width and thickness. Finally, we demonstrated that the SCTS can be successfully implementation inside the hip joints of miniaturized hydraulically actuated quadruped robot-MiniHyQ. This communication is based on work presented at the 18th International Conference on Climbing and Walking Robots (CLAWAR).
- 25 August 2015
- Published by World Scientific Pub Co Pte Ltd
- p. 309-316
AN INNOVATIVE TORQUE SENSOR DESIGN FOR THE LIGHTEST HYDRAULIC QUADRUPED ROBOT
- 25 August 2015
- Published by World Scientific Pub Co Pte Ltd
- p. 309-316
AN INNOVATIVE TORQUE SENSOR DESIGN FOR THE LIGHTEST HYDRAULIC QUADRUPED ROBOT
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23250526,p. 1-6
Development of the lightweight hydraulic quadruped robot — MiniHyQ
This paper presents the development of the lightweight hydraulic quadruped robot MiniHyQ. To the authors' best knowledge, MiniHyQ is the lightest and smallest hydraulic quadruped robot that has been built so far. MiniHyQ is a fully torque controlled robot. It has reconfigurable leg configurations. It has wide joint range of motion and an onboard compact power pack. The robot has almost the same leg length as the previous robot (HyQ [1], built by our group), but its link segment lengths are 15% less in flex configuration, due to the special isogram knee joint mechanism. Its weight is only 35kg (24kg with an offboard pump unit), which makes it portable by one person. To achieve this lightweight, miniature hydraulic actuators were carefully selected, allowing us to reduce the required pump size inside the torso. By using a hydraulic rotary actuator for the hip and linear actuators with isogram mechanism for the knee joint, a wider range of motion is achieved, allowing a self-righting motion. For the design validation and hardware testing, series of experiments are conducted on MiniHyQ single leg.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23250526,p. 1-6
Development of the lightweight hydraulic quadruped robot — MiniHyQ
This paper presents the development of the lightweight hydraulic quadruped robot MiniHyQ. To the authors' best knowledge, MiniHyQ is the lightest and smallest hydraulic quadruped robot that has been built so far. MiniHyQ is a fully torque controlled robot. It has reconfigurable leg configurations. It has wide joint range of motion and an onboard compact power pack. The robot has almost the same leg length as the previous robot (HyQ [1], built by our group), but its link segment lengths are 15% less in flex configuration, due to the special isogram knee joint mechanism. Its weight is only 35kg (24kg with an offboard pump unit), which makes it portable by one person. To achieve this lightweight, miniature hydraulic actuators were carefully selected, allowing us to reduce the required pump size inside the torso. By using a hydraulic rotary actuator for the hip and linear actuators with isogram mechanism for the knee joint, a wider range of motion is achieved, allowing a self-righting motion. For the design validation and hardware testing, series of experiments are conducted on MiniHyQ single leg.
- 6 February 2015
- Published by Zhejiang University Press in Frontiers of Information Technology & Electronic Engineering
- Vol. 16 (2) , 166-172
Longitudinal and lateral slip control of autonomous wheeled mobile robot for trajectory tracking
This research formulates a path-following control problem subjected to wheel slippage and skid and solves it using a logic-based control scheme for a wheel
- 6 February 2015
- Published by Zhejiang University Press in Frontiers of Information Technology & Electronic Engineering
- Vol. 16 (2) , 166-172
Longitudinal and lateral slip control of autonomous wheeled mobile robot for trajectory tracking
This research formulates a path-following control problem subjected to wheel slippage and skid and solves it using a logic-based control scheme for a wheel
- 1 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 325-331
Bio-inspired knee joint mechanism for a hydraulic quadruped robot
Over the last few decades, legged robots are becoming a promising solution for rough terrain navigation, however, existing legged machines often lack versatility to perform a wide range of different gaits. To build a highly dynamic and versatile legged robot, it is essential to have lightweight legs with optimized design and suitable actuators for the desired robot performance and tasks. The design goals are to achieve (1) a wide range of motion for bigger foot workspace which will increase rough terrain walking performance by increasing the number of reachable footholds for each step, (2) optimized joint torque curve since torque output is related to joint angle if linear actuators like pistons are used. In this paper, we focus on the knee joint and propose the adaptation and optimization of the so-called isogram mechanism. It exhibits a changeable instantaneous center of rotation (CICR), similar to a human knee joint. We will show how an optimization of design parameters lead to a knee joint design that satisfies the above-mentioned goals. The main contributions of this paper are the kinematic and torque analysis of the isogram mechanism that is actuated by a linear actuator; the optimization of the mechanism's design parameters; a comparison between the proposed knee joint with the hinge-type knee joint of the quadruped robot HyQ; and experimental results of a proof-of-concept prototype leg featuring the proposed mechanism.
- 1 February 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 325-331
Bio-inspired knee joint mechanism for a hydraulic quadruped robot
Over the last few decades, legged robots are becoming a promising solution for rough terrain navigation, however, existing legged machines often lack versatility to perform a wide range of different gaits. To build a highly dynamic and versatile legged robot, it is essential to have lightweight legs with optimized design and suitable actuators for the desired robot performance and tasks. The design goals are to achieve (1) a wide range of motion for bigger foot workspace which will increase rough terrain walking performance by increasing the number of reachable footholds for each step, (2) optimized joint torque curve since torque output is related to joint angle if linear actuators like pistons are used. In this paper, we focus on the knee joint and propose the adaptation and optimization of the so-called isogram mechanism. It exhibits a changeable instantaneous center of rotation (CICR), similar to a human knee joint. We will show how an optimization of design parameters lead to a knee joint design that satisfies the above-mentioned goals. The main contributions of this paper are the kinematic and torque analysis of the isogram mechanism that is actuated by a linear actuator; the optimization of the mechanism's design parameters; a comparison between the proposed knee joint with the hinge-type knee joint of the quadruped robot HyQ; and experimental results of a proof-of-concept prototype leg featuring the proposed mechanism.
- Open Access
- 19 November 2014
- Published by Kaunas University of Technology (KTU) in Elektronika ir Elektrotechnika
- Vol. 20 (9) , 3-8
A Unified SLAM Solution Using Partial 3D Structure
A Unified SLAM Solution Using Partial 3D Structure
- 19 November 2014
- Published by Kaunas University of Technology (KTU) in Elektronika ir Elektrotechnika
- Vol. 20 (9) , 3-8
Open AccessA Unified SLAM Solution Using Partial 3D Structure
A Unified SLAM Solution Using Partial 3D Structure
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 29, 112-117
Robotized task time scheduling and optimization based on Genetic Algorithms for non redundant industrial manipulators
Industrial robot manipulators must work as fast as possible in order to increase the productivity. This goal could be achieved by increasing robots speed or/and optimizing the trajectories followed by robots while performing assembly, welding or similar tasks. In our contribution, we focus on the second aspect and we target the shortening of paths between task-points. In other words, the goal is to find the shorter traveled distance between different configurations in the coordinate space. In addition to the short distance goal, we aim as well to impose both IKM (Inverse Kinematic Model) and the relative position and orientation of the manipulator regarding the task-points. To this end, we propose an optimization method based on Genetics Algorithms. The method is validated via numerical and graphical simulation, where, results show that the total cycle time required to perform a spot-welding task of an industrial car-body by a 6-DOFs (Degree Of Freedoms) industrial manipulator was drastically reduced.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 29, 112-117
Robotized task time scheduling and optimization based on Genetic Algorithms for non redundant industrial manipulators
Industrial robot manipulators must work as fast as possible in order to increase the productivity. This goal could be achieved by increasing robots speed or/and optimizing the trajectories followed by robots while performing assembly, welding or similar tasks. In our contribution, we focus on the second aspect and we target the shortening of paths between task-points. In other words, the goal is to find the shorter traveled distance between different configurations in the coordinate space. In addition to the short distance goal, we aim as well to impose both IKM (Inverse Kinematic Model) and the relative position and orientation of the manipulator regarding the task-points. To this end, we propose an optimization method based on Genetics Algorithms. The method is validated via numerical and graphical simulation, where, results show that the total cycle time required to perform a spot-welding task of an industrial car-body by a 6-DOFs (Degree Of Freedoms) industrial manipulator was drastically reduced.
- 1 January 2014
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 34 (2) , 79-89
A novel exoskeleton robotic system for hand rehabilitation – Conceptualization to prototyping
- 1 January 2014
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 34 (2) , 79-89
A novel exoskeleton robotic system for hand rehabilitation – Conceptualization to prototyping