Enhanced Wind Turbine Main Drivetrain Gearbox and Bearing Monitoring and Diagnostics Via Information Fusion of Acoustic, Electrical, and Vibration Signatures
Authors:
- 1 May 2019
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 51-56
Abstract
Main Drivetrain components are widely acknowledged as one of the most significant contributors to wind turbine downtime. This paper investigates the possibility of using acoustic signals to detect various wind turbine drivetrain defects, and proposes an enhanced wind turbine main drivetrain monitoring solution, where acoustic analysis is combined with electrical and vibration analysis via Gaussian model-based fusion algorithm. A 25hp wind turbine simulator is set up in the lab and is used to validate the proposed fusion algorithm. It is shown by experimental results that the proposed fusion-based monitoring solution significantly outperformed solutions using individual signals in detecting drivetrain gear and bearing defects at different load and speed operation conditions. This work turns out to be the first effort to fuse/combine acoustic, electrical and vibration signatures to monitor wind turbine main drivetrain anomalies.Keywords
This publication has 13 references indexed in Scilit:
- An enhanced active DC-flux injection based approach for thermal monitoring of induction machines with direct torque control schemes2017
- A high-frequency torque injection-based rotor thermal monitoring scheme for direct-torque-controlled interior permanent magnet synchronous machines2017
- A high-frequency rotating flux injection based rotor thermal monitoring scheme for direct-torque-controlled interior permanent magnet synchronous machines2017
- An improved DC-signal-injection method with active torque-ripple mitigation for thermal monitoring of field-oriented-controlled induction motors2015
- Stator Temperature Estimation of Direct-Torque-Controlled Induction Machines via Active Flux or Torque InjectionIEEE Transactions on Power Electronics, 2015
- Detection of Gearbox Bearing Defects Using Electrical Signature Analysis for Doubly Fed Wind GeneratorsIEEE Transactions on Industry Applications, 2014
- Adaptive Multi-Mode Power Control of a Direct-Drive PM Wind Generation System in a MicrogridIEEE Journal of Emerging and Selected Topics in Power Electronics, 2013
- A DC-flux-injection approach for thermal monitoring of induction machines with direct torque control2013
- A torque-injection-based approach for thermal monitoring of induction machines with direct torque control2013
- Novel adaptive power control of a Direct-drive PM wind generation system in a micro grid2012