Influence of spurious hemolysis on blood gas analysis
Authors:
- 5 January 2013
- journal article
- research article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 51 (8) , 1651-1654
Abstract
Background:Although the prevalence of hemolyzed samples referred for blood gas analysis is as high as 4%, no studies have assessed the bias introduced by spurious erythrocyte breakdown, nor it is known which parameters are mostly influenced and to what extent. This study was hence planned to assess the influence of spurious hemolysis on venous blood gas analysis.Methods:Venous blood was collected from nine healthy volunteers in sodium heparin tubes and divided in two aliquots of 3 mL. The former aliquot was mechanically hemolyzed by aspiration with 0.5 mL insulin syringe equipped with 30 gauge needle. One milliliter of all aliquots was tested for hemoglobin, pH, oxygen partial pressure (pO2), partial pressure of carbon dioxide (pCO2), bicarbonate (HCO3–), oxygen tension at 50% hemoglobin saturation (p50), oxygen saturation (sO2), actual base excess (ABE), carboxyhemoglobin (COHb), methemoglobin (metHb), ionized calcium (Ca2+) and potassium, on ABL800 flex. The remaining 2 mL of blood were centrifuged, plasma separated and tested for hemolysis index.Results:The concentration of cell-free hemoglobin increased from 2(−4.9%), sO2(−4.9%), COHb (−11%) and Ca2+(−7.0%), whereas significant increases were observed for pCO2(+4.1%), HCO3–(+1.4%) and potassium (+152%). Clinically meaningful bias was found for pO2, pCO2, Ca2+and potassium.Conclusions:Spurious hemolysis is likely to introduce meaningful biases in blood gas analysis, hence manufacturers of blood gas analyzers should develop instrumentation capable of identifying interfering substances in whole blood. The presence of spurious hemolysis should also be suspected whenever test results do not reflect the clinics.Keywords
This publication has 6 references indexed in Scilit:
- Hemolysis, lipaemia and icterus in specimens for arterial blood gas analysisClinical Biochemistry, 2012
- Influence of in vitro hemolysis on hematological testing on Advia 2120International Journal of Laboratory Hematology, 2011
- Comparison of 3 different multianalyte point-of-care devices during clinical routine on a medical intensive care unitJournal of Critical Care, 2011
- The use of serial patient blood gas, electrolyte and glucose results to derive biologic variation: a new tool to assess the acceptability of intensive care unit testingClinical Chemistry and Laboratory Medicine (CCLM), 2010
- Preanalytical variability: the dark side of the moon in laboratory testingClinical Chemistry and Laboratory Medicine (CCLM), 2006
- Current databases on biological variation: pros, cons and progressScandinavian Journal of Clinical and Laboratory Investigation, 1999