The use of serial patient blood gas, electrolyte and glucose results to derive biologic variation: a new tool to assess the acceptability of intensive care unit testing
- 27 July 2010
- journal article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 48 (10) , 1447-1454
Abstract
Background: Most estimates of biologic variation (sb) are based on periodically acquiring and storing specimens, followed by analysis within a single analytic run. We demonstrate for many intensive care unit (ICU) tests, only patient results need be statistically analyzed to provide reliable estimates of sb. Methods: Over 11 months, approximately 28,000 blood gas measurements (including electrolyte panels and glucose) were performed on one of two Radiometer ABL800 FLEX analyzers (Radiometer, Copenhagen, Denmark) from 1676 ICU patients. We tabulated the measurements of paired intra-patient blood samples drawn within 24 h of each other. After removal of outliers, we calculated the standard deviations of duplicates (SDD) of the intra-patient pairs grouped in 2-h intervals: 0–2 h, 2–4 h, 4–6 h, … 20–22 h and 22–24 h. The SDDs were then regressed against the time intervals of 2–14 h; extrapolation to zero time represents the sum of sb and short-term analytic variation (sa). Results: Substitution of experimentally derived analytic error permitted the calculation of coefficient of variation (biologic) (CVb) (100 sb/mean): pH, 0.3%; pCO2, 5.7%; pO2, 13%; Na+, 0.6%; K+, 4.8%; Cl–, 0.8%; HCO3 –, 3.2%; iCa++, 2.4%; and glucose, 10.3%. The CVb of the electrolytes very closely matches the lowest estimates obtained in the usual manner. Conclusions: Derivation of the ratio of biologic to analytic variation indicates that the ABL800 is extremely suitable for ICU testing. This analysis should be extended to other point of care instrument systems. Clin Chem Lab Med 2010;48:1447–54.Keywords
This publication has 17 references indexed in Scilit:
- Application of 3-D Δ Check Graphs to HbA1cQuality Control and HbA1cUtilizationAmerican Journal of Clinical Pathology, 2008
- Use of 2 years of patient data to estimate intra-laboratory total imprecision of HbA1c measured by multiple HPLC analyzersClinical Biochemistry, 2008
- Within-subject biological variation in disease: collated data and clinical consequencesAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2007
- Inherent biological variation and reference valuesClinical Chemistry and Laboratory Medicine (CCLM), 2004
- Unique Approach to Derivation of Random Error in Laboratory Assays: Application to Glycohemoglobin Testing Demonstrates Poor Clinical Performance for Immunochemistry AssayDiabetes Technology & Therapeutics, 2003
- Combination of analytical quality specifications based on biological within- and between-subject variationAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2002
- Are equally spaced specimen collections necessary to assess biological variation?: Evidence from renal transplant recipientsClinica Chimica Acta, 2000
- Proposals for Setting Generally Applicable Quality Goals Solely Based on BiologyAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1997
- Generation and Application of Data on Biological Variation in Clinical ChemistryCritical Reviews in Clinical Laboratory Sciences, 1989
- Assessment of “Average of Normals” Quality Control Procedures and Guidelines for ImplementationAmerican Journal of Clinical Pathology, 1984