The origin of order effects in the results of the bi-thermal caloric test
- 1 January 2004
- journal article
- research article
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 43 (5) , 276-282
Abstract
An order effect, characterized by a progressive decline inresponse magnitude, has been observed in the caloric test,and it has been suggested that the effect may be counteredby applying a correction. This study was undertaken todetermine whether the effect has its origin in physiologicaladaptation or in calibration drift of the recording system.Thirty-two normal subjects underwent the caloric test, inwhich their nystagmus was monitored simultaneously byboth electronystagmography (ENG) and videonystagmography(VNG). The experimental design also allowed otheraspects of the caloric test sequence to be investigated. Noevidence of physiological adaptation of the response wasseen. However, there was a significant change in corneoretinalpotential, and hence ENG calibration, during thetests. This was more marked if subjects' eyes were maintainedin darkness. It is recommended that no correctionbe made for order effects but that the calibration of ENGbasedsystems is adjusted immediately prior to eachcaloric irrigation. Sumario Se ha observado un efecto de orden en las pruebas calóricas,caracterizado por una disminución progresiva enla magnitud de la respuesta, y se ha sugerido que esteefecto puede ser contrarrestado aplicando una corrección.Este estudio se realizó para determinar si el efectotiene su origen en la adaptación fisiológica o en un fenómenode desviación al calibrar el sistema de registro.Treinta y dos sujetos normales fueron sometidos a unaprueba calórica en la que su nistagmo fue monitorizado simultáneamente por electronistagmografía (ENG) y porvideonistagmografía (VNG). El diseño experimental también permitió que se investigaran otros aspectos de lasecuencia en la prueba calórica. No se observó ningunaevidencia de adaptación fisiológica de la respuesta. Sinembargo, existió un cambio significativo en el potencialcórneo-retiniano, y por tanto, en la calibración del ENGdurante la prueba. Esto ocurrió más marcadamente si losojos se mantenían en la oscuridad. Se recomienda norealizar ninguna corrección para el efecto de orden, sinoque la calibración de los sistemas de ENG se ajuste inmediatamente antes de cada irrigación calórica.Keywords
This publication has 8 references indexed in Scilit:
- Variations in Calibration for Computerized ElectronystagmographyBritish Journal of Audiology, 1999
- Recommended procedureBritish Journal of Audiology, 1999
- Video-Oculography as Part of the ENG BatteryBritish Journal of Audiology, 1998
- A comparison of test-retest variability of caloric induced nystagmus in a normal population using an air stimulus presented via a standard and modified irrigating probeBritish Journal of Audiology, 1996
- Jongkees' Formula Re-evaluated: Order Effects in the Response to Alternate Binaural Bithermal Caloric Stimulation Using Closed-Loop IrrigationActa Oto-Laryngologica, 1993
- Illumiaance and Recording of Eye Movements by Electro-OculographyBritish Journal of Audiology, 1983
- Corneoretinal Potential Variations: Significance in ElectronystagmographyJAMA Otolaryngology–Head & Neck Surgery, 1980
- Some observations on the relationship between the standing potential of the human eye and the bleaching and regeneration of visual purpleThe Journal of Physiology, 1962