Guy Lightfoot
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Guy Lightfoot has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
John Stevens
2 shared publicationsVicki Kennedy
Department of Clinical Engineering, Royal Liverpool University Hospital, Prescot Street, Liverpool, England
2 shared publicationsAdrian Cairns
Audiology Department, Royal Liverpool University Hospital, Liverpool, UK
1 shared publicationAndre Lodwig
Technical University of Munich, Germany
1 shared publicationFiona Barker
East Berkshire Audiology Unit, King Edward VII Hospital, Windsor, England
1 shared publicationFrances Tweedy
Audiology Department, Manchester Royal Infirmary, Oxford Road, Manchester, England
1 shared publication
Latest Publications
- 9 December 2013
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 53 (2) , 132-137
Provisional stimulus level corrections for low frequency bone-conduction ABR in babies under three months corrected age
Objective: To estimate bone-conduction stimulus level corrections by testing the auditory brainstem response (ABR) of normally-hearing newborns. The stimuli used were low frequency tone pips calibrated to reference levels derived from ISO 389 values. Design: Tone pips were presented via supra-aural earphones and a B71 Radioear bone vibrator at 0.5 or 1 kHz. ABR thresholds from both transducers were compared at each frequency. Study sample: twenty-seven newborn hearing screening referrals (33 ears) who passed an ABR discharge criterion at 4 kHz. Results: Median air- and bone-conduction ABR threshold differences were 30 dB at 0.5 kHz and 20 dB at 1 kHz. Conclusion: The 0.5 kHz data from this study and previous studies were compared. Previous studies suggested lower figures for the bone-conduction stimulus level correction. Likely sources of this discrepancy are discussed. The average 0.5 kHz bone-conduction correction value for infants < 3 months old is about 28 dB. The correction for 1 kHz is 20 dB. We recommend that calibration reference levels used in this study be adopted and that appropriate corrections be applied to bone conduction ABR thresholds in infants < 3 months old before calculation of any air-bone gap and subsequent clinical interpretation.
- 9 December 2013
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 53 (2) , 132-137
Provisional stimulus level corrections for low frequency bone-conduction ABR in babies under three months corrected age
Objective: To estimate bone-conduction stimulus level corrections by testing the auditory brainstem response (ABR) of normally-hearing newborns. The stimuli used were low frequency tone pips calibrated to reference levels derived from ISO 389 values. Design: Tone pips were presented via supra-aural earphones and a B71 Radioear bone vibrator at 0.5 or 1 kHz. ABR thresholds from both transducers were compared at each frequency. Study sample: twenty-seven newborn hearing screening referrals (33 ears) who passed an ABR discharge criterion at 4 kHz. Results: Median air- and bone-conduction ABR threshold differences were 30 dB at 0.5 kHz and 20 dB at 1 kHz. Conclusion: The 0.5 kHz data from this study and previous studies were compared. Previous studies suggested lower figures for the bone-conduction stimulus level correction. Likely sources of this discrepancy are discussed. The average 0.5 kHz bone-conduction correction value for infants < 3 months old is about 28 dB. The correction for 1 kHz is 20 dB. We recommend that calibration reference levels used in this study be adopted and that appropriate corrections be applied to bone conduction ABR thresholds in infants < 3 months old before calculation of any air-bone gap and subsequent clinical interpretation.
- 2 June 2010
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 49 (10) , 772-774
The dependency of air caloric stimulus effectiveness on delivery tip characteristics
This brief study investigates the extent and origin of the apparent dependency of air delivery speculum size on the effectiveness of air used as a stimulus in the bi-thermal caloric test, using water as a reference stimulus. Eleven normal volunteers served as subjects. Six caloric stimulus delivery conditions included air with two speculum sizes, speculum only and with a rubber tube extension, and water. The resulting nystagmus was used as an index of stimulus efficiency. The effectiveness of the air stimulus was found to be dependent on the diameter of the speculum used for air delivery. The narrower speculum generated nystagmus that was typically twice that generated by the wider speculum. Users of air caloric equipment whose design includes a speculum that influences the effectiveness of the stimulus should be aware of this dependency and ensure their clinical interpretation of results is made with reference to appropriate normative data. Sumario Este breve estudio investigó la dimensión y el origen de la aparente dependencia del tamaño de la punta de estimulación, en la efectividad del aire que se usa como estímulo en la prueba calórica bitermica, usando agua como estímulo de referencia. Once voluntarios normales sirvieron como muestra. Seis condiciones de estimulación incluyeron aire con dos tamaños de espéculos, un espéculo aislado o con un tubo de extensión de hule, y agua. El nistagmo resultante se usó como índice de la eficiencia del estímulo. Se encontró que la efectividad del estímulo con aire es dependiente del diámetro del espéculo usado para el envío del aire. El espéculo más estrecho, generó un nistagmo que fue típicamente del doble que el generado con el espéculo más ancho. Los usuarios de equipo calórico con aire, cuyo diseño incluye un espéculo, deben estar concientes de esa dependencia y estar seguros de que sus interpretaciones clínicas de los resultados, se hagan con referencia a datos normativos apropiados.
- 2 June 2010
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 49 (10) , 772-774
The dependency of air caloric stimulus effectiveness on delivery tip characteristics
This brief study investigates the extent and origin of the apparent dependency of air delivery speculum size on the effectiveness of air used as a stimulus in the bi-thermal caloric test, using water as a reference stimulus. Eleven normal volunteers served as subjects. Six caloric stimulus delivery conditions included air with two speculum sizes, speculum only and with a rubber tube extension, and water. The resulting nystagmus was used as an index of stimulus efficiency. The effectiveness of the air stimulus was found to be dependent on the diameter of the speculum used for air delivery. The narrower speculum generated nystagmus that was typically twice that generated by the wider speculum. Users of air caloric equipment whose design includes a speculum that influences the effectiveness of the stimulus should be aware of this dependency and ensure their clinical interpretation of results is made with reference to appropriate normative data. Sumario Este breve estudio investigó la dimensión y el origen de la aparente dependencia del tamaño de la punta de estimulación, en la efectividad del aire que se usa como estímulo en la prueba calórica bitermica, usando agua como estímulo de referencia. Once voluntarios normales sirvieron como muestra. Seis condiciones de estimulación incluyeron aire con dos tamaños de espéculos, un espéculo aislado o con un tubo de extensión de hule, y agua. El nistagmo resultante se usó como índice de la eficiencia del estímulo. Se encontró que la efectividad del estímulo con aire es dependiente del diámetro del espéculo usado para el envío del aire. El espéculo más estrecho, generó un nistagmo que fue típicamente del doble que el generado con el espéculo más ancho. Los usuarios de equipo calórico con aire, cuyo diseño incluye un espéculo, deben estar concientes de esa dependencia y estar seguros de que sus interpretaciones clínicas de los resultados, se hagan con referencia a datos normativos apropiados.
- 2 June 2010
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 49 (10) , 794-798
Noise levels required to mask stimuli used in auditory brainstem response testing
The levels of noise necessary to effectively mask the stimuli commonly used in auditory brainstem response (ABR) tests were determined. The relative masking level (RLM) of twenty normally-hearing volunteers was measured behaviourally using ipsilaterally presented unfiltered noise in the presence of ABR stimuli. The upper limit for RLM was found to be typically 30 dB above the stimulus level when the stimulus was calibrated in dBnHL to ISO 389-6 (2007) and the noise was measured in dBSPL. This value is recommended when calculating the level of noise necessary to prevent cross-hearing during ABR testing. Sumario Se determinaron los niveles de ruido necesarios para enmascarar efectivamente los estímulos comúnmente utilizados en las pruebas de respuestas auditivas del tallo cerebral (ABR). Se midió en forma conductual el nivel de enmascaramiento relativo (RLM) de veinte voluntarios con audición normal, usando ruido no filtrado presentado ipsilateralmente en presencia de estímulos para ABR. Se encontró que el límite superior del RLM típicamente era de 30 dB por encima de nivel del estímulo cuando el estímulo estaba calibrado en dB nHL para ISO 389-6 (2007) y el ruido era medido en dB SPL. Este valor es recomendado cuando se calcula el nivel de ruido necesario para prevenir audición cruzada durante la evaluación con ABR.
- 2 June 2010
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 49 (10) , 794-798
Noise levels required to mask stimuli used in auditory brainstem response testing
The levels of noise necessary to effectively mask the stimuli commonly used in auditory brainstem response (ABR) tests were determined. The relative masking level (RLM) of twenty normally-hearing volunteers was measured behaviourally using ipsilaterally presented unfiltered noise in the presence of ABR stimuli. The upper limit for RLM was found to be typically 30 dB above the stimulus level when the stimulus was calibrated in dBnHL to ISO 389-6 (2007) and the noise was measured in dBSPL. This value is recommended when calculating the level of noise necessary to prevent cross-hearing during ABR testing. Sumario Se determinaron los niveles de ruido necesarios para enmascarar efectivamente los estímulos comúnmente utilizados en las pruebas de respuestas auditivas del tallo cerebral (ABR). Se midió en forma conductual el nivel de enmascaramiento relativo (RLM) de veinte voluntarios con audición normal, usando ruido no filtrado presentado ipsilateralmente en presencia de estímulos para ABR. Se encontró que el límite superior del RLM típicamente era de 30 dB por encima de nivel del estímulo cuando el estímulo estaba calibrado en dB nHL para ISO 389-6 (2007) y el ruido era medido en dB SPL. Este valor es recomendado cuando se calcula el nivel de ruido necesario para prevenir audición cruzada durante la evaluación con ABR.
- 1 February 2009
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 30 (1) , 54-62
The Derivation of Optimum Criteria for Use in the Monothermal Caloric Screening Test
Objective: The aim of this study was to determine whether it is possible to predict a normal outcome of the bithermal caloric test by testing at a single temperature and if so, what criteria are most appropriate to use. Design: A total of 490 patients were considered candidates for the bithermal test and 414 completed the four necessary components, their nystagmus being measured using videonystagmography. Results: Clinical decision analysis revealed that the cool monothermal test does not provide an adequate combination of sensitivity and specificity for us to recommend its clinical use. However, the warm monothermal test offers a sensitivity of 95% with 29% of patients with normal bithermal results having to undergo the bithermal test (specificity = 71%) if a combination of three criteria are used: a normal bithermal caloric test outcome can be anticipated and testing curtailed after the first temperature if (a) the warm monothermal caloric asymmetry (MCA) is 8 degrees per sec (°/sec), and (c) any spontaneous nystagmus is <4 °/sec. Conclusions: When appropriate criteria are used, the warm monothermal caloric test offers a performance that is acceptable for routine clinical use, sparing a considerable proportion of patients from unnecessary tests at the cool temperature. We believe that the warm/cool monothermal test difference is probably a consequence of the interrelationship between canal paresis and directional preponderance.
- 1 February 2009
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 30 (1) , 54-62
The Derivation of Optimum Criteria for Use in the Monothermal Caloric Screening Test
Objective: The aim of this study was to determine whether it is possible to predict a normal outcome of the bithermal caloric test by testing at a single temperature and if so, what criteria are most appropriate to use. Design: A total of 490 patients were considered candidates for the bithermal test and 414 completed the four necessary components, their nystagmus being measured using videonystagmography. Results: Clinical decision analysis revealed that the cool monothermal test does not provide an adequate combination of sensitivity and specificity for us to recommend its clinical use. However, the warm monothermal test offers a sensitivity of 95% with 29% of patients with normal bithermal results having to undergo the bithermal test (specificity = 71%) if a combination of three criteria are used: a normal bithermal caloric test outcome can be anticipated and testing curtailed after the first temperature if (a) the warm monothermal caloric asymmetry (MCA) is 8 degrees per sec (°/sec), and (c) any spontaneous nystagmus is <4 °/sec. Conclusions: When appropriate criteria are used, the warm monothermal caloric test offers a performance that is acceptable for routine clinical use, sparing a considerable proportion of patients from unnecessary tests at the cool temperature. We believe that the warm/cool monothermal test difference is probably a consequence of the interrelationship between canal paresis and directional preponderance.
- 1 December 2007
- Published by American Speech Language Hearing Association in American Journal of Audiology
- Vol. 16 (2) , 94-95
Stimulus Repetition Rate and the Reference Levels for Clicks and Short Tone Bursts: A Warning to Audiologists, Researchers, Calibration Laboratories, and Equipment Manufacturers
Purpose: To make the audiologic community aware of a technical issue with potential for misunderstanding that could affect the design, calibration, and use of auditory brainstem response (ABR) systems. Method: Two international standards published in 2007 relating to the stimuli commonly used in ABR tests were studied and the behavior of a commercially available ABR system examined with regard to the relationship between stimulus level and repetition rate. Results: There is potential for misunderstanding of the need to compensate for the effect of stimulus rate on stimulus level. Although rapidly presented stimuli appear louder as the rate is increased, it is inappropriate to compensate for this when calibrating the stimulus level of ABR systems. Conclusions: Users of ABR systems should, if possible, use the stimulus reference levels now available in an international standard rather than establish local values. No adjustment of level should be made to account for different stimulus repetition rates. Users of ABR systems should check their systems to ensure that no automatic level adjustment is made; if necessary, equipment manufacturers should be consulted.
- 1 December 2007
- Published by American Speech Language Hearing Association in American Journal of Audiology
- Vol. 16 (2) , 94-95
Stimulus Repetition Rate and the Reference Levels for Clicks and Short Tone Bursts: A Warning to Audiologists, Researchers, Calibration Laboratories, and Equipment Manufacturers
Purpose: To make the audiologic community aware of a technical issue with potential for misunderstanding that could affect the design, calibration, and use of auditory brainstem response (ABR) systems. Method: Two international standards published in 2007 relating to the stimuli commonly used in ABR tests were studied and the behavior of a commercially available ABR system examined with regard to the relationship between stimulus level and repetition rate. Results: There is potential for misunderstanding of the need to compensate for the effect of stimulus rate on stimulus level. Although rapidly presented stimuli appear louder as the rate is increased, it is inappropriate to compensate for this when calibrating the stimulus level of ABR systems. Conclusions: Users of ABR systems should, if possible, use the stimulus reference levels now available in an international standard rather than establish local values. No adjustment of level should be made to account for different stimulus repetition rates. Users of ABR systems should check their systems to ensure that no automatic level adjustment is made; if necessary, equipment manufacturers should be consulted.
- 1 October 2006
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 27 (5) , 443-456
Cortical Electric Response Audiometry Hearing Threshold Estimation: Accuracy, Speed, and the Effects of Stimulus Presentation Features
A number of stimulus presentation features of the tone burst-evoked N1-P2 cortical response were investigated to identify any advantage over simple stimulation when the test is used for hearing threshold estimation. The speed of establishing objective thresholds at 1, 3, and 8 kHz in both ears was also measured in what was designed to be an efficient test protocol, together with the precision of the threshold estimates with reference to subjects' conventional audiograms. Twenty-four volunteer subjects were recruited and tested by both behavioral and electrophysiological methods. A low-intensity, 3-kHz stimulus was used when the stimulus features were studied. The parameter was the N1-P2 amplitude. Changing the side of presentation (randomly or by alternating ears), varying the interstimulus interval and inserting a 10-second recovery period midway though an averaging run had no demonstrable effect on response amplitude, both individually or in combination, contrary to earlier reports. Establishing the 6 threshold estimates took an average 20.6 minutes. The mean error in the N1-P2 threshold estimate was 6.5 dB, with no significant effect of frequency. After correcting for this bias, 94% of individual threshold estimates were within 15 dB of the behavioral threshold and 80% were within 10 dB. This study suggests that cortical electric response audiometry has a performance that is as good as or better than the auditory brain stem response for threshold estimation in adults and that sophisticated stimulation techniques do not appear to be required. An efficient test protocol that automates many laborious tasks reduces the test time to less than half that previously reported in the literature for this response.
- 1 October 2006
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 27 (5) , 443-456
Cortical Electric Response Audiometry Hearing Threshold Estimation: Accuracy, Speed, and the Effects of Stimulus Presentation Features
A number of stimulus presentation features of the tone burst-evoked N1-P2 cortical response were investigated to identify any advantage over simple stimulation when the test is used for hearing threshold estimation. The speed of establishing objective thresholds at 1, 3, and 8 kHz in both ears was also measured in what was designed to be an efficient test protocol, together with the precision of the threshold estimates with reference to subjects' conventional audiograms. Twenty-four volunteer subjects were recruited and tested by both behavioral and electrophysiological methods. A low-intensity, 3-kHz stimulus was used when the stimulus features were studied. The parameter was the N1-P2 amplitude. Changing the side of presentation (randomly or by alternating ears), varying the interstimulus interval and inserting a 10-second recovery period midway though an averaging run had no demonstrable effect on response amplitude, both individually or in combination, contrary to earlier reports. Establishing the 6 threshold estimates took an average 20.6 minutes. The mean error in the N1-P2 threshold estimate was 6.5 dB, with no significant effect of frequency. After correcting for this bias, 94% of individual threshold estimates were within 15 dB of the behavioral threshold and 80% were within 10 dB. This study suggests that cortical electric response audiometry has a performance that is as good as or better than the auditory brain stem response for threshold estimation in adults and that sophisticated stimulation techniques do not appear to be required. An efficient test protocol that automates many laborious tasks reduces the test time to less than half that previously reported in the literature for this response.
- 1 January 2004
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 43 (5) , 276-282
The origin of order effects in the results of the bi-thermal caloric test
An order effect, characterized by a progressive decline inresponse magnitude, has been observed in the caloric test,and it has been suggested that the effect may be counteredby applying a correction. This study was undertaken todetermine whether the effect has its origin in physiologicaladaptation or in calibration drift of the recording system.Thirty-two normal subjects underwent the caloric test, inwhich their nystagmus was monitored simultaneously byboth electronystagmography (ENG) and videonystagmography(VNG). The experimental design also allowed otheraspects of the caloric test sequence to be investigated. Noevidence of physiological adaptation of the response wasseen. However, there was a significant change in corneoretinalpotential, and hence ENG calibration, during thetests. This was more marked if subjects' eyes were maintainedin darkness. It is recommended that no correctionbe made for order effects but that the calibration of ENGbasedsystems is adjusted immediately prior to eachcaloric irrigation. Sumario Se ha observado un efecto de orden en las pruebas calóricas,caracterizado por una disminución progresiva enla magnitud de la respuesta, y se ha sugerido que esteefecto puede ser contrarrestado aplicando una corrección.Este estudio se realizó para determinar si el efectotiene su origen en la adaptación fisiológica o en un fenómenode desviación al calibrar el sistema de registro.Treinta y dos sujetos normales fueron sometidos a unaprueba calórica en la que su nistagmo fue monitorizado simultáneamente por electronistagmografía (ENG) y porvideonistagmografía (VNG). El diseño experimental también permitió que se investigaran otros aspectos de lasecuencia en la prueba calórica. No se observó ningunaevidencia de adaptación fisiológica de la respuesta. Sinembargo, existió un cambio significativo en el potencialcórneo-retiniano, y por tanto, en la calibración del ENGdurante la prueba. Esto ocurrió más marcadamente si losojos se mantenían en la oscuridad. Se recomienda norealizar ninguna corrección para el efecto de orden, sinoque la calibración de los sistemas de ENG se ajuste inmediatamente antes de cada irrigación calórica.
- 1 January 2004
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 43 (5) , 276-282
The origin of order effects in the results of the bi-thermal caloric test
An order effect, characterized by a progressive decline inresponse magnitude, has been observed in the caloric test,and it has been suggested that the effect may be counteredby applying a correction. This study was undertaken todetermine whether the effect has its origin in physiologicaladaptation or in calibration drift of the recording system.Thirty-two normal subjects underwent the caloric test, inwhich their nystagmus was monitored simultaneously byboth electronystagmography (ENG) and videonystagmography(VNG). The experimental design also allowed otheraspects of the caloric test sequence to be investigated. Noevidence of physiological adaptation of the response wasseen. However, there was a significant change in corneoretinalpotential, and hence ENG calibration, during thetests. This was more marked if subjects' eyes were maintainedin darkness. It is recommended that no correctionbe made for order effects but that the calibration of ENGbasedsystems is adjusted immediately prior to eachcaloric irrigation. Sumario Se ha observado un efecto de orden en las pruebas calóricas,caracterizado por una disminución progresiva enla magnitud de la respuesta, y se ha sugerido que esteefecto puede ser contrarrestado aplicando una corrección.Este estudio se realizó para determinar si el efectotiene su origen en la adaptación fisiológica o en un fenómenode desviación al calibrar el sistema de registro.Treinta y dos sujetos normales fueron sometidos a unaprueba calórica en la que su nistagmo fue monitorizado simultáneamente por electronistagmografía (ENG) y porvideonistagmografía (VNG). El diseño experimental también permitió que se investigaran otros aspectos de lasecuencia en la prueba calórica. No se observó ningunaevidencia de adaptación fisiológica de la respuesta. Sinembargo, existió un cambio significativo en el potencialcórneo-retiniano, y por tanto, en la calibración del ENGdurante la prueba. Esto ocurrió más marcadamente si losojos se mantenían en la oscuridad. Se recomienda norealizar ninguna corrección para el efecto de orden, sinoque la calibración de los sistemas de ENG se ajuste inmediatamente antes de cada irrigación calórica.
- 1 October 2000
- Published by Taylor & Francis in British Journal of Audiology
- Vol. 34 (5) , 311-316
Audiometer calibration: interpreting and applying the standards.
A degree of judgement is required when applying the British Standard associated with the calibration and performance of audiometers, BS EN 60645-1 (IEC 645-1). Consequently there is potential for variation of practice between calibration agencies. This note addresses issues and makes suggestions relating to the measurement of distortion, on-off effect, cross talk, linearity, rise/fall time and to the positioning of the earphone on an artificial ear. The degree of precision appropriate to each measurement is suggested. A warning is given of the audiological consequences of excessive distortion produced by normally functioning audiometers.
- 1 October 2000
- Published by Taylor & Francis in British Journal of Audiology
- Vol. 34 (5) , 311-316
Audiometer calibration: interpreting and applying the standards.
A degree of judgement is required when applying the British Standard associated with the calibration and performance of audiometers, BS EN 60645-1 (IEC 645-1). Consequently there is potential for variation of practice between calibration agencies. This note addresses issues and makes suggestions relating to the measurement of distortion, on-off effect, cross talk, linearity, rise/fall time and to the positioning of the earphone on an artificial ear. The degree of precision appropriate to each measurement is suggested. A warning is given of the audiological consequences of excessive distortion produced by normally functioning audiometers.