Estimation of speed of sound using coherence factor and signal-to-noise ratio for improvement of performance of ultrasonic beamformer
Authors:
- Fumitada SannouFSFumitada Sannou
- Ryo NagaokaRNRyo Nagaoka
- Hideyuki HasegawaHHHideyuki Hasegawa
- 27 April 2020
- journal article
- conference paper
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 59 (SK) , SKKE14
Abstract
Ultrasound beamforming is an indispensable process to obtain an ultrasound image. In the conventional ultrasonography, the speed of sound (SoS) in tissue is assumed to be constant to calculate the distance from the scattering point to each ultrasonic transducer element. However, the spatial distribution of the SoS in tissue is inhomogeneous. In this study, we developed a method to estimate the distribution of the SoS. In addition, the accuracy of the proposed method was investigated using a homogeneous phantom with a known SoS distribution. Furthermore, another experiment using a wire phantom was conducted to investigate whether the spatial resolution in a resultant ultrasound image was improved with the SoS distribution estimated by the proposed method. The best spatial resolution was achieved when the size of the transmit aperture was 6.4 mm (32 elements) when both the coherence factor and signal-to-noise ratio factor were evaluated with a 7.5 MHz linear array probe.Keywords
This publication has 28 references indexed in Scilit:
- A New Method for Measuring the Speed of Sound in Rat Liver ex Vivo Using an Ultrasound System: Correlation of Sound Speed with Fat DepositionUltrasound in Medicine & Biology, 2014
- Ex vivo Study of Quantitative Ultrasound Parameters in Fatty Rabbit LiversUltrasound in Medicine & Biology, 2012
- The diagnosis and management of non-alcoholic fatty liver disease: Practice Guideline by the American Association for the Study of Liver Diseases, American College of Gastroenterology, and the American Gastroenterological AssociationHepatology, 2012
- A CT based correction method for speed of sound aberration for ultrasound based image guided radiotherapyMedical Physics, 2011
- Broadband measurements of the frequency dependence of attenuation coefficient and velocity in amniotic fluid, urine and human serum albumin solutionsUltrasound in Medicine & Biology, 2005
- Relationship Between Speed of Sound in and Density of Normal and Diseased Rat LiversJapanese Journal of Applied Physics, 1994
- Pulse-echo ultrasound speed measurements: Progress and prospectsUltrasound in Medicine & Biology, 1991
- Acoustic Properties of Tissue at Ultrasonic Frequencies1990
- Phase Aberration Measurements in Medical Ultrasound: Human StudiesUltrasonic Imaging, 1988
- Explososcan: A parallel processing technique for high speed ultrasound imaging with linear phased arraysThe Journal of the Acoustical Society of America, 1984