Multi-capillary column-ion mobility spectrometry (MCC-IMS) as a new method for the quantification of occupational exposure to sevoflurane in anaesthesia workplaces: an observational feasibility study
Open Access
- 27 March 2015
- journal article
- research article
- Published by Springer Nature in Journal of Occupational Medicine and Toxicology
- Vol. 10 (1) , 1-9
Abstract
Occupational exposure to sevoflurane has the potential to cause health damage in hospital personnel. Workplace contamination with the substance mostly is assessed by using photoacoustic infrared spectrometry with detection limits of 10 ppbv. Multi-capillary column-ion mobility spectrometry (MCC-IMS) could be an alternative technology for the quantification of sevoflurane in the room air and could be even more accurate because of potentially lower detection limits. The aim of this study was to test the hypothesis that MCC-IMS is able to detect and monitor very low concentrations of sevoflurane (<10 ppbv) and to evaluate the exposure of hospital personnel to sevoflurane during paediatric anaesthesia and in the post anaesthesia care unit (PACU). A MCC-IMS device was calibrated to several concentrations of sevoflurane and limits of detection (LOD) and quantification (LOQ) were calculated. Sevoflurane exposure of hospital personnel was measured at two anaesthesia workplaces and time-weighted average (TWA) values were calculated. The LOD was 0.0068 ppbv and the LOQ was 0.0189 ppbv. During paediatric anaesthesia the mean sevoflurane concentration was 46.9 ppbv (8.0 - 314.7 ppbv) with TWA values between 5.8 and 45.7 ppbv. In the PACU the mean sevoflurane concentration was 27.9 ppbv (8.0 – 170.2 ppbv) and TWA values reached from 8.3 to 45.1 ppbv. MCC-IMS shows a significantly lower LOD and LOQ than comparable methods. It is a reliable technology for monitoring sevoflurane concentrations at anaesthesia workplaces and has a particular strength in quantifying low-level contaminations of sevoflurane. The exposure of the personnel working in these areas did not exceed recommended limits and therefore adverse health effects are unlikely.Keywords
This publication has 25 references indexed in Scilit:
- Detection and validation of volatile metabolic patterns over different strains of two human pathogenic bacteria during their growth in a complex medium using multi-capillary column-ion mobility spectrometry (MCC-IMS)Applied Microbiology and Biotechnology, 2013
- Volatile Organic Compounds in UremiaPLOS ONE, 2012
- Ion mobility spectrometry for microbial volatile organic compounds: a new identification tool for human pathogenic bacteriaApplied Microbiology and Biotechnology, 2012
- Occupational exposure to sevoflurane during cardiopulmonary bypassPerfusion, 2011
- Personnel breathing zone sevoflurane concentration adherence to occupational exposure limits in conjunction with filling of vaporisersActa Anaesthesiologica Scandinavica, 2010
- Increased formation of sister chromatid exchanges, but not of micronuclei, in anaesthetists exposed to low levels of sevofluraneAnaesthesia, 2008
- Behavioural effects of chronic exposure to sub-anesthetic concentrations of halothane, sevoflurane and desflurane in ratsCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2006
- Online Monitoring of Air Quality at the Postanesthetic Care Unit by Proton-Transfer-Reaction Mass Spectrometry2001
- Exposure to Sevoflurane and Nitrous Oxide During Four Different Methods of Anesthetic InductionAnesthesia & Analgesia, 1999
- Exposure to Sevoflurane and Nitrous Oxide During Four Different Methods of Anesthetic InductionAnesthesia & Analgesia, 1999